Town Center L2B1-LR 951228 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: CLIENT: North Texas Contracting, Inc. DATE: 28 December 1995 PROJECT: Wendy's Town Center, Coppell, TX SUPPLIER: Lattimore LOCATION OF POUR SET 1: Storm drain inlet bottom, center inlet on east side of Spine Rd. LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. 42 Truck No. 33 i Cement Ticket No. 3020501 Flyash Time Batched 12:58pm Sand Time Sampled 1:45pm in. Concrete Temp. (ASTM C10641 61 °F 1.0 in. Air Content (ASTM C231) 4.2% Water Unit Weight (ASTM C138) Admix //1 Admix //2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 1 2 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day {ASTM C143) psi Strength 16 2.50 7 01/04/96 150,400 5320 17 2.50 7 01/04/96 148,200 5240 1 8 2.50 28 01/25/96 19 2.50 28 01/25/96 28-Day Average 3000 TECHNICIAN: MFM (1:15pm-2:45pm) ~ ~__ , DISTRIBUTION: (2) North Texas Contracting, Inc. (1) City of Coppell, Larry Davis 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF IN-PLACE DENSITY TESTS CLIENT: North Texas Contracting, Inc. DATE: 28 December 1995 PROJECT: Wendy's Towne Center, Coppell, TX MATERIAL DESCRIPTION: 1) On-Site Fill - Light Brown & Orange Sandy Clay ASTM D 698 STANDARD PROCTOR: 1) 106.0 pcf @ 15.0% Moisture MOISTURE DRY PERCENT REQUIRED LOCATION PROCTOR LIFT CONTENT DENSITY COMPACTION COMPACTION % PCF % % BELOW Backfill Over Water Line-Towne Center Blvd. SUBGRADE 35) approx. 50' west of east "T" 1 5' 19.4 104.3 98.4 95 + -2% to +4% 36). approx. 15' west of east "T" 1 1' 1 8.3 103.2 97.4 Of Optimum TECHNICIAN: CDJ DISTRIBUTION: (2) North Texas Contracting, Inc. (1) City of Coppell, Larry Davis 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: CLIENT: North Texas Contracting, Inc. DATE: 28 December 1995 PROJECT: Wendy's Town Center, Coppell, TX SUPPLIER: Lattimore LOCATION OF POUR SET 1: Storm drain inlet bottom, center inlet on east side of Spine Rd. LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. 42 Truck No. 331 Cement Ticket No. 3020501 Flyash Time Batched 12:58pm Sand Time Sampled 1:45pm in. Concrete Temp. (ASTM C1064) 61 °F 1.0 in. Air Content (ASTM C231) 4.2% Water Unit Weight (ASTM C138! Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) · Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day IASTM C143} psi Strength 16 2.50 7 01/04/96 150,400 5320 17 2.50 7 01/04/96 148,200 5240 18 2.50 28 01/25/96 1_80,000 6370 19 2.50 28 01/25/96 :17:1,600 6070 28-Day Average 6220 3000 TECHNICIAN: MFM (1:15pm-2:45pm) DISTRIBUTION: (2) North Texas Contracting, Inc. (1) City of Coppell, Larry Davis 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148