Town Center L2B1-LR 951208 Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REPORT OF IN-PLACE DENSITY TESTS
CLIENT: North Texas Contracting, Inc. DATE: 8 December 1995
PROJECT: Wendy's Towne Center, Coppell, TX
MATERIAL DESCRIPTION: 1) On-Site Fill - Grey & Brown Sandy Clay
ASTM D 698 STANDARD PROCTOR: 1) 111.0 pcf@ 13.0% Moist~Jre
MOISTURE DRY PERCENT REQUIRED
LOCATION PROCTOR LIFT CONTENT DENSITY COMPACTION COMPACTION
% PCF % %
BELOW
Backfill Over Sanitary Sewer Line A SUBGRADE
26) approx. Station 13+20 1 4' 12.2 101.4 91.4 90+
-2% to +4%
27) approx. Station 14+60 (@ manhole) 1 6' 12.7 101.1 91.1 Of Optimum
Backfill Over Town Center Water Line
28) approx. Station 1 ~- 25 1 Fin. Sub. 11.0 102.3 92.1
TECHNICIAN: CDJ ~ ~
DISTRIBUTION: (2) North Texas Contracting, inc. ~f..~ '- ' ·
(1) City of Coppell, Larry Davis
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148