Loading...
Town Center L1B1-LR 960104 PARKLAND ENGINEERING & TESTING, INC. GEOTECHNICAL ENGINEERING CONSULTANTS 3601 KlM DRIVE, SUITE 102 P.O. BOX 154196 IRVING, TEXAS 75015 PETER YU. M.S., P.E. TEL: (214)986-1694 PRESIDENT CONCRETE TEST-STRENGTH REPORT FAX: (214) 790-5378 Overton Bank & Trust 1-Client CLIENT; P.O. Box 948 COPIES TO: 1-Innovative Coppell, Texas75019 Developers, Inc. 1-City of Coppell PROJECT: Overton Bank & Trust Bldg.-102,N.Denton Tap Road, Coppell, Tx. CONTRACTOR.. Innovative Developers, Inc. ,Fort Worth,Tx. P.O.NO: CONCRETE SUPPLIER: Redi Mix Concrete ( Plant 1) 28 DAY DESIGN STRENGTH: 4,000 PSI LOCATION: Parking Lot/Fire Lane-45'N., 26 'W. of JOB NO: 95-173-1 N.W. Building Corner. COEPRESSIVE STRENGTH TESTS (6" X 12" CYLINDER) CYLINDER DATE OF DATE AGE COMPRESSIVE TYPE OF REMARKS NUMBER PLACEMENT TESTED DAYS STRENGTH, PSI FAILURE 697 1-04-96 1-11-96 7 day 3,113 C 5 gallons of water 698 1-04-96 2-01-96 28 day 4,174 C were added prior 699 1-04-96 2-01-96 28 day 4,118 C to slump testing. ADMIXTURES 1% Calcium MEASURED SLUMP 54 IN MAXIMUM AGGREGATE SIZE --- AIR CONTENT --- AIR TEMPERATURE 48 °F TIME-BATCH 8: 33 AM CONCRETE TEMPERATURE 52 °F TIME-TEST 9: 15 AM TRUCK NO. 116 SPECIMEN MADE BY'. Lab. MIX DESIGN NO. 6 Sack Mix TECHNICIAN TIME: 4.0hrs. PA~TING, INC. C D V T 0 TESTED IN ACCORDANCE WITH ASTM STANDARDS PARKLAND ENGINEERING & TESTING, INC. GEOTECHNICAL ENGINEERING CONSULTANTS 3601 KlM DRIVE, SUITE 102 P.O. BOX 154196 IRVING, TEXAS 7501 5 PETER YU, M.S., P.E. TEL: (214) 986-1694 PRESIDENT CONCRETE TEST-STRENGTH REPORT FAX: (214)790-5378 Overton Bank & Trust 1-Client CLIENT: P.O. Box 948 COPIES TO:l_innovative Coppell, Texas75019 Developers, Inc. 1-City of Coppell PROJECT: Overton Bank & Trust Bldg.-102,N.Denton Tap Road, Coppell, Tx. CONTRACTOR: Innovative Developers,Inc. ,Fort Worth,Tx. P.O.NO: CONCRETE SUPPLIER: Redi Mix Concrete ( Plant 1) 28 DAY DESIGN STRENGTH: 4,000 PSI LOCATION: Parkin§ Lot/Fire Lane-45'N. ,26'W.of JOB NO: 95-173-1 N.W. Building Corner. COMPRESSIVE STRENGTH TESTS (6" X 12" CYLINDER) CYLINDER DATE OF DATE AGE COMPRESSIVE TYPE OF REMARKS NUMBER PLACEMENT TESTED DAYS STRENGTH, PSI FAILURE 697 1-04-96 1-11-96 7 day 3,113 C 5 gallons of water 698 1-04-96 2-01-96 28 day were added prior 699 1-04-96 2-01-96 28 day to slump testing. ADMIXTURES 1% Calcium MEASURED SLUMP 5% IN MAXIMUM AGGREGATE SIZE --- AIR CONTENT --- % AIR TEMPERATURE 48 °F TIME-BATCH 8:33 AM CONCRETE TEMPERATURE 52 °F TIME-TEST 9: 15 AM TRUCK NO. 116 SPECIMEN MADE BY: Lab. MIX DESIGN NO. 6 Sack Mix TECHNICIAN TIME: 4.0hrs. C D V T O TESTED IN' ACCORDANCE \VITH ASTM STANDARDS