Loading...
Town Center L1B1-LR 951221 PARKLAND ENGINEERING & TESTING, INC. GEOTECHNICAL ENGINEERING CONSULTANTS 3601 KlM DRIVE, SUITE 102 P.O. BOX 154196 IRVING, TEXAS 75015 PETER YU. M.S., P.E. TEL: (214) 986-1694 PRESIDENT CONCRETE TEST-STRENGTH REPORT FAX; (214) 790-5378 CLIENT: Overton Bank & Trust COPIES TO: l- Client P.O. Box 948 1- Innovative Coppell, Texas 75019 Developers,Inc 1- City of Copell PROJECT: Overton Bank & Trust Building-102,N.Denton Tap Road, Coppell, Tx. CONTRACTOR: Innovative Developers, Inc. ,Fort Worth,Tx. P.O.NO: CONCRETE SUPPLIER: Redi Mix Concrete ( PLant 1) 28 DAY DESIGN STRENGTH: 4,000 PSI LOCATION: Parking Lot -East Fire Lane @ Approach JOB NO: 95-173-1 :5' E.from W. side curb, 84'N.from street. COHPRESSIVE STRENGTH TESTS (6" X 12" CYLINDER) CYLINDER DATE OF DATE AGE COMPRESSIVE TYPE OF REMARKS NUMBER PLACEMENT TESTED DAYS STRENGTH, PSI FAILURE SWL-1 12-21-95 12-28-95 7 day 3,530 --- SWL-2 12-21-95 1-18-96 28 day 5,060 --- SWL-3 12-21-95 1-18-96 28 day 5,300 --- SWL-4 12-21-95 Hold Hold ADMIXTURES 1% calcium added MEASURED SLUMP 7.0 IN MAXIMUM AGGREGATE SIZE --- AIR CONTENT 5.2 % AIR TEMPERATURE 35 °F TIME-BATCH --- CONCRETE TEMPERATURE 61 oF TIME-TEST 10: 35 AM TRUCK NO. 190 SPECIMEN MADE BY: Maxim MIX DESIGN NO. 4,000 PSI TECHNICIAN TIME: 4.0 hrs. PARKLAND ENGINEERING & TESTING, INC. C D V T 0 TESTED IN' ACCORDANCE WITH ASTM STANDARDS PARKLAND ENGINEERING & TESTING, INC. GEOTECHNICAL ENGINEERING CONSULTANTS 3601 KlM DRIVE, SUITE 102 P.O. BOX 154196 IRVING, TEXAS 75015 PETER YU, M.S., P.E. TEL: (214) 986-1694 PRESIDENT CONCRETE TEST-STRENGTH REPORT FAX: (214) 790-5378 CLIENT: Overton Bank & Trust COPIES TO: 1- Client P.O. Box 948 1- Innovative Coppell, Texas 75019 Developers,Inc 1- City of Copell PROJECT: Overton Bank & Trust Building-102,N.Denton Tap Road,Coppell,Tx. CONTRACTOR: Innovative Developers, Inc. ,Fort Worth,Tx. P.O.NO: CONCRETE SUPPLIER: Redi Mix Concrete ( PLant 1) 28 DAY DESIGN STRENGTH: 4,000 PSI LOCATION: Parking Lot -East Fire Lane @ Approach JOB NO: 95-173-1 :5' E.from W. side curb, 84'N.from street. COMPRESSIVE STRENGTH TESTS (6" X 12" CYLINDER) CYLINDER DATE OF DATE AGE COMPRESSIVE TYPE OF REMARKS NUMBER PLACEMENT TESTED DAYS STRENGTH, PSI FAILURE SWL-1 12-21-95 12-28-95 7 day 3,530 --- SWL-2 12-21-95 1-18-96 28 day SWL-3 12-21-95 1-18-96 28 day SWL-4 12-21-95 Hold Hold I I ADMIXTURES 1% calcium added MEASURED SLUMP 7.0 IN MAXIMUM AGGREGATE SIZE --- AIR CONTENT 5.2 % AIR TEMPERATURE 35 o F T IME-BATCH - - - CONCRETE TEMPERATURE 61 °F TIME-TEST 10: 35 AM TRUCK NO. 190 SPECIMEN MADE BY: Maxim MIX DESIGN NO. 4,000 PSI TECHNICIAN TIME: 4.0 hrs. PAr~K~ AND E~'GINEERINO & TESTING, INC. ....... C D V T O TESTED IN ACCORDANCE WITH ASTM STANDARDS