Loading...
Town Center L1B1-LR 951214 PARKLAND ENGINEERING & TESTING, INC. GEOTECHNICAL ENGINEERING CONSULTANTS 3601 KlM DRIVE, SUITE 102 P.O. BOX 154196 IRVING, TEXAS 75015 PETER YU. M.S., P.E. TEL.' (214) 986-1694 PRESIDENT CONCRETE TEST-STRENGTH REPORT FAX: (214) 790-5378 Overton Bank & Trust 1-Client CLIENT: P.O. Box 948 COPIES TO: 1-Innovative Coppell, Texas 75019 Developers, Inc. 1-City of Coppell PROJECT: Overton Bank & Trust Bldg.-102,N.Denton Tap Road, Coppell, Tx. CONTRACTOR: Innovative Developers, Inc. ,Fort Worth,Tx. P.O.NO: CONCRETE SUPPLIER: Redi Mix Concrete ( Plant 1) 28 DAY DESIGN STRENGTH: 3,000 PSI 95-173-1 LOCATION: Drive-In Facility: 25'S. ,12'E.of JOB NO: N.W. Canopy Corner/ Pavement. COEPRESSIVE STRENGTH TESTS (6" X 12" CYLINDER) CYLINDER DATE OF DATE AGE COMPRESSIVE TYPE OF REMARKS NUMBER PLACEMENT TESTED DAYS STRENGTH, PSI FAILURE 694 12-14-95 12-21-95 7 day 3,042 C 695 12-14-95 1-11-96 28 day 3,608 C 696 12-14-95 1-11-96 28 day 3,659 C I ADMIXTURES AEA MEASURED SLUMP 4.0 IN MAXIMUM AGGREGATE SIZE --- AIR CONTENT --- % AIR TEMPERATURE 76 °F TIME-BATC~ 8:37 AM CONCRETE TEMPERATURE 68 °F TIME-TEST 9: 20 AM TRUCK NO. 106 SPECIMEN MADE BY: Lab. MIX DESIGN NO. 5 Sack Mix TECHNICIAN TIME: 4.0 hrs. o f Failure: PARKLAND ENGINEERING & TESTING, INC. Typ e s Peter Yu, M. S., P. E. C D Y T O TESTED IN ACCORDANCE WITH ASTM STANDARDS PARKLAND ENGINEERING & TESTING, INC. GEOTECHNICAL ENGINEERING CONSULTANTS 3601 KlM DRIVE, SUITE 102 P.O. BOX 1 54196 IRVING, TEXAS 75015 PETER YU, M.S., P.E. TEL: (214) 986-1694 PRESIDENT CONCRETE TEST-STRENGTH REPORT FAX: (214) 790-5378 Overton Bank & Trust 1-Client CLIENT: P.O. Box 948 COPIES TO: 1-Innovative Coppell, Texas 75019 Developers, Inc. 1-City of Coppell PROJECT: Overton Bank & Trust Bldg.-102,N.Denton Tap Road, Coppell, Tx. CONTRACTOR: Innovative Developers, Inc. ,Fort Worth,Tx. P.O.NO: CONCRETE SUPPLIER: Redi Mix Concrete ( Plant 1) 28 DAY DESIGN STRENGTH: 3,000 PSI 95-173-1 LOCATION: Drive-In Facility: 25'S. ,12'E.of JOB NO: N.W. Canopy Corner/ Pavement. COMPRESSIVE STRENGTH TESTS (6" X 12" CYLINDER) CYLINDER DATE OF DATE AGE COMPRESSIVE TYPE OF REMARKS NUMBER PLACEMENT TESTED DAYS STRENGTH, PSI FAILURE 694 12-14-95 12-21-95 7 day 3,042 C 695 12-14-95 1-11-96 28 day 696 12-14-95 1-11-96 28 day I ADMIXTURES AEA MEASURED SLUMP 4.0 IN MAXIMUM AGGREGATE SIZE AIR CONTENT --- % AIR TEMPERATURE 76 OF TIME-BATCH 8:37 AM CONCRETE TEMPERATURE 68 °F TIME-TEST 9: 20 AM TRUCK NO. 106 SPECIMEN MADE BY: Lab. MIX DESIGN NO. 5 Sack Mix TECHNICIAN TIME: 4.0 hrs. ~Typ e sEo f Fa ~ E ~i lure: -~' - '~ter Y~ ~~ PARKLANDS, ~N_'G~NEERING & TESTING, INC. C D V T 0 ~/ TESTEI) IN ACCORDANCE WITH AS'FM STANDARDS