Town Center L3B1-LR 960226 (2)ALPHA TESTING,
2209 Wisconsin St.
Suite 100
Dallas, Texas 75229
(214) 620-8911
REPORT CONCRETE
COMPRESSION TEST
TESTED FOR: GASKE CONSTURCTION
BELLAIRE, TEXAS
DATE OF ISSUE:
FEBRUARY 26, 1996
PROJECT:
COMERICA BANK
COPPELL, TEXAS
OUR REPORT NO.:
95760-22
FIELD DATA
LOCATION OF CONCRETE PLACEMENT
DATE PLACED
TIME
SLUMP (ASTM C-143)
AIR CONTENT (ASTM C-231 [] OR C-173 r~)
AIR TEMPERATURE
CONCRETE TEMPERATURE
DATE RECEIVED
FIELD DATA SUBMrl-rED BY
PAVING, 30' W. AND 30' N. OF THE N.W
CORNER OF BLDG. SLAB.
02/19/96 PLANT N/A
13: 2 9 DELIVER TICKET NO 11740
N/A* MiX PROPORTIONS (SSD) N/A
N/A* CEMENT N/"A
70 WATER
69 FINE AGGREGATE N/A
02/20/96 COARSE AGGREGATE
DW ADMIXTURE N/A
MIX DATA SUBMI'I=rED BY M I D C ~,T I ES
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM O-617 [] OR C-1231 []
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6" X 12")
(ASTM C-39)
~B TYPE DATE AGE TOTAL AREA COMPRESSIVE
NO. CURING TESTED DAYS LOAD STRENGTH, PSI
25 LAB 02/26/96 7 80,505 28.27 2,850
26 LAB 03/18/96 28 116,350 28.27 4,120
27 LAB 03/18/96 28 125,690 28.27 4,450
28 LAB HOLD H 28.27
Specific~ions 28 3,000
* STEVE W/GASKE DID NOT WANT SLUMP OR AIR TAKEN.
COMPUDATA-CG01083-34
REMARKS
[~'~ylinders made by ALPHA
representative.
[] Cylinders made by Architect's
or Contractor's representative.
~""~ylinders picked up by ALPHA
laboratory.
[] Cylinders delivered to ALPHA
laboratory.
[~ompressions test results comply with
applicable specifications.
[] Compression test results do not comply
with applicable specifications.