ST9302-LR011031 ALPHA TESTING, INC. Concrete Compression Test
2209 Wisconsin St., Suite 1 O0
Dallas, Texas 75229
(972) 620-8911
Tested For: CITY OF COPPELL Our Report No.: 98881-220
ATTN: KEN GRIFFIN Issue Date: 10/31/2001
255 PARKWAY BLVD.
COPPELL, TX 75019
Fax Number; (972) 304-3570
Project Desc: SANDY LAKE ROAD PROJ NO. ST 93
COPPELL, TEXAS
FIELD DA TA
Placement Location: PAVING, STATION 19+60 AT THE INTERSECTION OF MACARTHUR AND SANDY LAKE RD.
Date Placed: 9/18/01 Plant Number: 41-6.0 SK
Time Placed: 1:15 PM Delivery Ticket No.: 2982256
Slump (ASTM C-143): 4.0 Made By: ALPHA
Air Content: 4.0 (ASTM C-173) Cured Specification: ASTM C-31
Air Temperature: 80
Specimen Temperature: 83
Date Received: 9/19/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: SULLIVAN, JASON
Mix Data Submitted By: TXI
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI:
310 LAB C-1231 9/25/01 7 12 N/A 6 28.27 126723 4480
311 LAB C-1231 10/16/01 28 12 N/A 6 28.27 170310 6020
312 LAB C-1231 10/16/01 28 12 N/A 6 28.27 180780 6390
313 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3500
~ Date: PASS
Notes:
CC: CITY OF COPPELL, ED BELL CONSTRUCTION
Respectfully Submitted By: :0;~/~ ~ of Alpha Testing, Inc.
Our test results and reports are for the exclusive u e elr designated receplents on file In our office) and shall not be reproduced and/or distributed except
with express approval of AI-PHA. The use oi~ our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed, and are not Indicative of the qualifies of apparendy identical or similar specimens.
ALPHA TESTING, INC. Concrete Compression Test
2209 Wisconsin St., Suite ~00
Dallas, Texas 75229 Oe. or*
(972) 620-8911
Tested For: CITYOF COPPELL Our Report No.: 98881-225
ATTN: KEN GRIFFIN Issue Date: 10/31/2001
255 PARKWAY BLVD.
COPPELL, TX 75019
Fax Number: (972) 304-3570
Project Desc: SANDY LAKE ROAD PROJ NO. ST 93
COPPELL, TEXAS
FIELD DA TA
Placement Location: PAVING, 32'S & 45'W FROM THE SW CORNER OF STOP-N-GO
Date Placed: 10/10/01 Plant Number: N/A
Time Placed: 1:45 PM Delivery Ticket No.: N/A
Slump (ASTM C-t43): 4 Made By: ALPHA
Air Content: 5 (ASTM C-173) Cured Specification: ASTM C-31
Air Temperature: §1
Specimen Temperature: 90
Date Received: 10/11/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: TOLE, KEVIN
Mix Data Submitted By: N/A
CYLINDER COMPRESSION TEST RESUL TS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSi:
326 LAB C-1231 10/17/01 7 12 N/A 6 28.27 133260 4710
327 LAB 11/7/01 28 12 N/A 6 28.27 0
328 LAB 11/7/01 28 12 N/A 6 28.27 0
329 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3500
Results to Date: N/A
Notes:
CC: CITY OF COPPELL, ED BELL CONSTRUCTION
Respectfully Submitted By: ,,/7// of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client (and their designated receplents on file in our office) and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed, and are not Indicative of the qualities of apparently Identical or similar specimens.