Town Center L4B1-LR010913ALPHA TESTIN¢~, INC. 2209 Wisconsin St,, Suite 100 Do#os. Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX; 972t/406-.~23 REPORT OF PIER MONITORING TESTED FOR: PROJECT: Pier Information: Construction Management Group Dallas, Texas Coppell Town Center Coppell Texas DATE: OUR REPORT NUMBER ARCHITECT: GENERAL CONTRACTOR: PIER CONTRACTOR: CONCRETE SUPPLIER: 13-Sep-01 01612-12 F.W.N.A. C. M. G. Lytle Conc. Beall Pier Designabon Date Pier Ddlled Date Concrete Placed Shaft Diameter- Design I Actual, in. Bell Diameter - Design / Actual, in. Top of Pier Elevation-Design I Actual, ff Bottom of Pier Elevation-Design I Actual, ff Dewabon from Design Elevation (ft+) Vertical Steel Reinforcing Verhcal Steel 3qe Reinfoming Splices (No. & Location) Length of Casing used, ff Depth to Bearing Strata, ff Total Depth of Drilled Pier Ground Surface Elevation A-2 B-2 C-2 C-1 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 18 18 18 18 18 18 18 18 54 54 54 54 54 54 54 54 96.5 99.0 99.0 96.5 90.5 86.2 90.5 86,2 90.5 87.3 90.5 88.5 4.3 4.3 3.2 2.0 4 #6's 4 #6's 4 #6's 4 ~6's #3's {~ 12" o.c. #3's ~ 1Z' o.c. #3's ~ 12" o.c. #3's (~ 12" o.c. N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 13.3 13.3 12.2 11.0 99.5 99.5 99.5 99.5 Respectfully Submitted · Alpha Testing, Inc. cc: Constr. Mngmt. Group; Jeff Miller~ .~n,~,,. ,~...,,, City of Coppell; Larry Daves, Lee Stone our test results & repolts are for the exclusive usa of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name & test results must receive our w/JUan approval. Test results & repo~s apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. REMARKS: Note: Per structural engineer; 9' minimum from existing grade in gray sandy clay. ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF PIER MONITORING TESTED FOR: PROJECT: Pier Information: Construction Management Group Dallas, Texas Coppell Town Center Coppell Texas DATE: OUR REPORT NUMBER: ARCHITECT: GENERAL CONTRACTOR: PIER CONTRACTOR: CONCRETE SUPPLIER: 13-Sep-01 01612-12A F. W. N. A. C. M, G. Lytle Conc. Beall Pier Designation Date Pier Ddlled Date Concrete Placed Shaft Diameter- Design / .~t,~al, in. Bell Diameter - Design / ActuaJ, in, Top of Pier Elevation-Design / Actual, ft Bottom of Pier Elevation-Design / Actual, fi Deviation from Design Elevation (h+) Ve~lical Stael Reinfoming Vertical Steel Tie Re~nforcing Splices (No. & Location) Length of Casing used, ft Depth to Bearing Strata, ft Total Depth of Dnlled Pier Ground Surface Elevation REMARKS: D.5-3 C-3 B-3 A-3.5 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 18 18 18 18 18 18 18 18 54 54 54 54 54 54 54 54 97.5 101.0 101.0 99.5 92.5 88.0 92.5 88.5 92.5 88.1 92.5 88.5 4.5 4.0 4.4 4.0 4 #6's 4 #6's 4 #6's 4 #6's #3's @ 12" o.c. #3's @ 12" o.c. #3's @ 12" o.c. #3's @ 12" o.c. N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 13.5 13.0 13.4 13.0 101.5 101.5 101.5 101.5 Note: Per structural engineer; 9' minimum fro,-n ~ Respectfully Submitted existing grade in gray sandy clay. ~ Alpha Testin~n~~ cc: Constr. Mngmt. Group; Jeff Miller Jl~an Orta City of Coppell; Larry Daves, Lee Stone ~ ....... our test results & reports are for the exclusive use of the Client (and their designated recipients on file in o~ced and/or distributed except with express approval of ALPHA. The use of our name & test results must receive our written appr~pply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. ALPHA TESTIN¢~, INC. 2209 WIsconsln St., Sulte 100 Dolk~ Texos 75229 972/620..891 ! - 972/263-4937 (Metro) FAX: REPORT OF PIER MONITORING TESTED FOR: PROJECT: Pier Information: Construction Management Group Dallas, Texas Coppell Town Center Coppell Texas DATE: OUR REPORT NUMBER ARCHITECT: GENERAL CONTRACTOR: PIER CONTRACTOR: CONCRETE SUPPLIER: 13-se~ol 01612-12B F.W. N A. C. M. G. Lytle Conc. Beall Pier Designation Date Pier Drilled Date Concrete Placed Shaft Diameter. Design I Actual, in. Bell Diameter - Design / Actual, in. Top of Pier Elevation-Design I Actual, ft Bottom of Pier Elevation-Design I Actual, ff Deviation from Design Elevation (ft+) Vertical Steel Reinforcing Vertical Steel Tm Reinforcing Spl~ces (No. & Location) Length of Casing used, ft Total Depth of Ddlled Pier Ground Surface Elevation REMARKS: B-4 A.7-4.2 A.7-5 A.7-4.5 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 18 18 18 18 18 18 18 18 101.0 99.5 99.5 99.5 92.5 89.5 92.5 89.7 92.5 89.2 92.5 89.0 3.0 2.8 3.3 3.5 4 ~"S 4 ~6's 4 ~6's 4 #6's ~3's Q 12" o.c. #3's Q 12" o.c. #3's ~) 1 2" o.c. t/3's ~ 12" o.c. NIA N/A N/A N/A N/A N/A N/A NIA NIA NIA N/A N/A 12.0 11.8 12.3 12.5 101.5 101.5 101.5 101.5 Note: Per structural engineer; 9' minimum from Respectfully Submitted existing grade in gray sandy clay. ~X--,~ Alpha Testi~]~i..r~. cc: Constr. Mngmt. Group; Jeff Miller ~ City of Coppell; Larry Oaves, Lee Stone ~ our test results & reports am for the exclusive use of the Client (and ~eir designated recipients on file in our office) and' shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name & ~ results must recede our written approval. Test msulte & reports apply only to the samples tested and/or obee~md, and are not indicative of the qualities of apparently identical or similar specimens. ALPHA TESTING, INC. 2209 tAr~consl~ St., Suite I00 Dallas, Texas 75229 972/620-891 ] o 972/263-4937 CMetro) FAX; 972~/406-8023 REPORT OF PIER MONITORING TESTED FOR: PROJECT: Pier Information: Construction Management Group Dallas, Texas Coppell Town Center Coppell Texas DATE: OUR REPORT NUMBER ARCHITECT: GENERAL CONTRACTOR: PIER CONTRACTOR: CONCRETE SUPPLIER: 13-Sep-01 01612-12C F.W.N.A. C. M. G. Lytle Conc. Beall Pier Designation Date Pier Drilled Date Concrete Placed :Shaft Diameter- Design I Actual, in Bell Diameter - Design I Actual, in. Top of Pier Elevation.Design I Actual, ft Bottom of Pier Elevation-Design I Actual, ff Deviation from Design Elevation Vertical Steel Reinforcing Vertical Steel Tie Reinforcing Splices (No. 8, Location) Length of Casing used, ff Depth to Bearing b-'bata, ff Total Depth of Drilled Pier Ground Surface Elevation REMARKS: C-5 B-5 D.5-4 D.5-4.5 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 13-Sep 18 18 18 18 18 18 18 18 54 54 54 54 54 54 54 54 101.0 99.5 99.5 99.5 92.5 89.5 92.5 89.3 92.5 88~5 92.5 88.6 3.0 3.2 4.0 3.9 4 #6's 4 #6's 4 #6's 4 #6's ft3's (~ 12" o,c. #3's ~ 12" o.c. i~r3's ~} 12" o.c. ~t3's ~ 12" o.c. N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A NIA 12.0 12.2 13.0 12.9 101.5 101.5 101.5 101.5 Note: Per structural engineer; 9' minimum from Respectfully Submitted existing grade in gray sandy clay. ~~ cc: Constr. Mngmt. Group; Jeff Miller ~Juan L)na City of Coppell; Larry Daves, Lee Stone ~ our test results & repolts ara for the exclusive use of the Client (and their designated recipients on file in our office) ad~ shall not be reproduced and/or d~sthbuted except with express approval of ALPHA. The use of our name & test results must receive our wt'itten approval. Test recruits & reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparenUy identical or similar specimens. ALPHA TESTING, INC. 220~ Wisconsin ,~.. Suite 100 ~ TexaS 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972(~406-8023 REPORT OF PIER MONITORING TESTED FOR: PROJECT: Pier Information: Construction Management Group Dallas, Texas Coppell Town Center Coppell Texas DATE: OUR REPORT NUMBER ARCHITECT: GENERAL CONTRACTOR: PIER CONTRACTOR: CONCRETE SUPPLIER: 13-Sep-01 01612-12D F.W.N.A. C. M. G. Lytle Conc. Beall Pier Designation Date Pier Ddlled Date Concrete Placed Shaft Diameter- Design I Actual, Bell Diameter - Design I Actual, in, Top of Pier Elevation-Design / Actual, ff Bottom of Pier Elevation-Design ! Actual, It Deviation from Design Elevation (ft'+) Verbcal Steel Reinforcing Veltical Steel Tie Reinforcing Splices {No. & Location) Length of Casing used, ft Depth to Beanng St~ate, It Total Depth of Drilled Pier Ground Surface Elevation D.5-3.5 C-4 1 3-Sep 1 3-Sep 1 3-Sep 13-Sep 18 18 18 18 54 54 54 54 99.5 101.0 92.5 88.5 92.5 89.0 4.0 3.5 4 #6's 4 f~6's #3's {~ 1 2" n.c. #3's ~ 1 2" n.c. N/A N/A N/A N/A N/A N/A 13.0 12.5 1 01.5 1 01.5 REMARKS: Note: Per structural engineer; 9' minimum from existing grade in gray sandy clay.  , Respectfully Submitted ",lAIpha Testing, Inc. cc: Constr. Mngmt. Group; Jeff Miller City of Coppell; Lam/Daves, Lee Stone Our test results & reports are fo~ the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The usa of our name & test results must receive our written approval. Test results & reports apply only to the samples tested and/or obseP~d, and are not indicative of the qualifies of apparently identical or similar specimens. ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 TESTED FOR CONSTRUCTION MANAGEMENT GROUP DALLAS, TEXAS REPOR I' OF FIELD COMPACTION TESTS DATE 09/13/01 PROJECT COPPELL TOWN CENTER COPPELL, TEXAS OUR REPORTNO. 01612-17 TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDE PT~,,,~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 29 09/13/01 FG-1.0 1 15.5 101 16.1 100 99 1-A 30 09/13/01 FG-1.0 1 15.5 101 19.0 100 99 1-A 31 09/13/01 FG 1 15.5 101 18.5 100 99 1-A 32 09/13/01 FG 1 15.5 101 17.3 98 97 1-A TEST LOCATION: 29 6" WATER LINE A AT STATION #0+00 30 6" WATER LINE B AT STATION #0+05 31 6" WATER LINE A AT STATION #0+10 32 6" WATER LINE B AT STATION #0+25 CC: LARRY DAVES, CITY OF COPPELL LEE STONE, CITY OF COPPELL I FILL * A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENTTREATED D RETEST Our test results & reports are for the exclusive use of the Client (and their designated recipients on file in our off,e) and shall not be reproduced and/or di.~'~xpress approva~f ALPHA. The use of our name & test results must receive, our written approval Test results & reports apply only to the samples tested and/or observed, and are not ind~cat~ve of the q~r~o ~..~ or s~milar specimens. Geotechnical Engineering · Construction Materials Testing · Enwronmental Engineering · Consulting