Town Center L4B1-LR011104ALPHA TESTING JC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
Concrete Co spression Test
Report
Tested For: CONSTRUCTION MANAGEMENT GROUP
ATTN: MR. JEFF MILLER
5207 MCKINNEY AVENUE, SUITE 12
DALLAS, TX 75205
Fax Number: (214) 521-1279
Project Desc: COPPELL TOWN CENTER
120 N. DENTON TAPP-- COPPELL, TX
Our Report No.: 01612-33
Issue Date: 11/04/2001
FIELD DA TA
Placement Location: SEE NOTES
Date Placed: 10/17/01
Time Placed: 3:05 PM
Slump (ASTM C-143): 4.5
Air Content: 5 (ASTM C-173)
Air Temperature: 76
Specimen Temperature: 78
Date Received: 10/18/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: MAGALLON, E.
Mix Data Submitted By: BEALL
Plant Number: 89-4000
Delivery Ticket No.: 89003583
Made By: ALPHA
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESUL TS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI:
41 LAB C-1231 10/24/01 7 12 N/A 6 28.27 99750 3520
42 LAB 11/14/01 28 12 N/A 6 28.27 0
43 LAB 11/14/01 28 12 N/A 6 28.27 0
44 LAB HOLD HOLD 12 N/A 6 28.27 0
i Specifications: 28 3600
Results to Date: N/A
Notes:
CC:
PAVING; PARKING LOT, 15'W & 10'S FROM THE SE INTERSECTION OF TOWN CENTER ST. & PARKING LOT
HIS, CITY OF COPPELL, CONSTRUCTION MANAGEMENT GROUP
Respectfully Submitted By: ~'/~/' of AJpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client (and ~elr designated receplents on file In our office) and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed, and are not Indicative of the qualifies of apparently identical or similar specimens.
ALPHA TESTING lC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
Concrete Coh.pression Test
Report
Tested For: CONSTRUCTION MANAGEMENT GROUP
ATTN: MR. JEFF MILLER
5207 MCKINNEY AVENUE, SUITE 12
DALLAS, TX 75205
Fax Number: (214) 521-1279
Project Desc: COPPELL TOWN CENTER
120 N. DENTON TAPP- COPPELL, TX
Our Report No.: 01612-32
Issue Date: 11/04/2001
FIELD DA TA
Placement Location:
Date Placed:
Time Placed:
Slump (ASTM C-143):
Air Content:
Air Temperature:
Specimen Temperature:
Date Received:
Delivery Method:
Field Data Submitted By:
Mix Data Submitted By:
PAVING; PARKING LOT, 20'E & 5'N FROM THE SE CORNER OF THE BUILDING
1 O/17/01
12:35 PM
5
4 (ASTM C-173)
75
77
10/18/01
PICKED UP BY ALPHA
MAGALLON, E.
BEALL
Plant Number: 89-4000
Delivery Ticket No.: 89003561
Made By: ALPHA
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESUL TS
Lab Cure Cap Date Age Avg. Avg, Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSi:
37 LAB C-1231 10/24/01 7 12 N/A 6 28.27 81600 2880
38 LAB 11/14/01 28 12 N/A 6 28.27 0
39 LAB 11/14/01 28 12 N/A 6 28.27 0
40 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3600
Results to Date: N/A
Notes:
CC:
HIS, CITY OF COPPELL, CONSTRUCTION MANAGEMENT GROUP
Respectfully Submitted By: ~./_// of Alpha Testing, Inc.
Our test results and reports are for the excludve use of the Client (and their designated receplents on file In our office) and shall not be reproduced and/or distributed except
wld~ express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and repons apply only to the samples tested and/or
observed, and are not Indicative of the qualities of apparently identlcal or dmllar specimens.
ALPHA TESTIN( NC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
Concrete Co,apression Test
Report
Tested For: CONSTRUCTION MANAGEMENT GROUP
ATTN: MR. JEFF MILLER
5207 MCKINNEY AVENUE, SUITE 12
DALLAS, TX 75205
Fax Number: (214) 521-1279
Project Dssc: COPPELL TOWN CENTER
120 N. DENTON TAPP- COPPELL, TX
Our Report No.: 01612-31
Issue Date: 11/04/2001
FIELD DA TA
Placement Location:
Date Placed:
Time Placed:
Slump (ASTM C-143):
Air Content:
Air Temperature:
Specimen Temperature:
Date Received:
Delivery Method:
Field Data Submitted By:
Mix Data Submitted By:
PAVING; PARKING LOT, 20'S & 15'E FROM THE NE CORNER OF THE BUILDING
10/17/01
7:15 AM
5
4.5 (ASTM C-173)
69
71
10/18/01
PICKED UP BY ALPHA
MAGALLON, E.
NELSON BROS.
Plant Number: -4000
Delivery Ticket No.: 102569
Made By: ALPHA
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESUL TS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI:
33 LAB C-1231 10/24/01 7 12 N/A 6 28.27 100700 3560
34 LAB 11/14/01 28 12 N/A 6 28.27 0
35 LAB 11/14/01 28 12 N/A 6 28.27 0
36 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3600
Results to Date: N/A
Notes:
CC:
HIS, CITY OF COPPELL, CONSTRUCTION MANAGEMENT GROUP
Respectfully Submitted By: ,/7~/ of Alpha Testing, Inc.
Our test resulls and reports are for the exclusive use of the Client (and their designated recepients on file In our office) and shall not be reproduced and/or dlsu'lbuted except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed, and are not Indicative of the qualities of apparenlty Idenltcal or similar specimens.
I