Town Center L4B1-LR010928ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
DAILY FIELD REPORT
TESTED FOR: CONSTRUCTION MANAGEMENT GROUP
DALLAS, TEXAS
PROJECT:
COPPELL TOWN CENTER
COPPELL, TEXAS
DATE: 09/28/01
OUR REPORT NO:
01612-22
TECHNICIAN: O.A.
WEATHER: CLEAR
TO 60
TEMPERATURE RANGE: 50
THE ALPHA TECHNICIAN TRAVELED TO THE ABOVE REFERENCED SITE TO MONITOR ON-GOING WORK AND
PERFORM FIELD TESTING AS REQUESTED.
THE TECHNICIAN OBSERVED THE PRE-POUR CONDITION OF FOUNDATION SLAB FOR THE ENTIRE BUILDING
FROM LINE A TO F BETWEEN LINE 1 TO 8. THE TECHNICIAN OBSERVED THE AREA FOR PROPER VAPOR
BARRIER, GRADE BEAM SIZE, AND STEEL REINFORCING. NO DEFICIENCIES WERE NOTED DURING THE
OBSERVATION.
THE TECHNICIAN MOLDED 3 SETS OF 4 TEST CYLINDERS FROM CONCRETE PLACED FOR SLAB ON THIS
DATE.
LABORATORY TEST RESULTS FOR ALL RELATED ITEMS REFERENCED ABOVE WILL FOLLOW ON A
SEPARATE REPORT.
LARRY WAS INFORMED OF ALL OBSERVATIONS AND FIELD TEST RESULTS.
AT THE COMPLETION OF THE SCHEDULED TESTING, THE TECHNICIAN RETURNED TO THE DALLAS OFFICE.
CC:
LARRY DAVES, CITY OF COPPELL
LEE STONE, CITY OF COPPELL
Our test results and rep<xts are for the exclusive use of the client (and their designated recipients on file in our office) and shal not be reproduced and/< distributed exce? ~ express eppr~r_-_a
ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or obsel ~d, and are not indicative of the qualities of
apparently identical or similar specimens.
Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting