Town Center L4B1-LR011025ALPHA TESTING, ,NC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
Tested For: CONSTRUCTION MANAGEMENT GROUP
ATTN: MR. JEFF MILLER
5207 MCKINNEY AVENUE, SUITE 12
DALLAS, TX 75205
Fax Number: (214) 521-1279
Project Desc: COPPELL TOWN CENTER
120 N. DENTON TAPP-- COPPELL, TX
Concrete Compression Test
Report
Our Report No.: 01612-19
Issue Date: 10/25/2001
FIELD DA TA
Placement Location:
Date Placed:
Time Placed:
Slump (ASTM C-143):
Air Content:
Air Temperature:
Specimen Temperature:
Date Received:
Delivery Method:
Field Data Submitted By:
Mix Data Submitted By:
PAVING, 59~N & 10'S FROM THE NW CORNER OF THE PROPOSED BUILDING
9/24/01
10:20 AM
5
5 (ASTM C-173)
70
89
9/25/01
PICKED UP BY ALPHA
BUSTAMANTE, MARTY
BEALL
Plant Number: 89-4000
Delivery Ticket No.: 89002475
Made By:. ALPHA
Cured Specification: ASTM C-31
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: {Oa~st: Len~lth Width Diameter Sq. In. Load: PSI:
17 LAB C-1231 10/1/01 7 12 N/A 6 28.27 114123 4030
18 LAB C-1231 10/22/01 28 12 N/A 6 28.27 153910 5440
19 LAB C- 1231 10/22/01 28 12 N/A 6 28.27 153700 5430
20 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3600
' Results to Date: PASS
Notes:
cc:
HIS, CITY OF COPPELL, CONSTRUCTION MANAGEMENT GROUP
Respectfully Submitted By: ~'.4~'~ ~.~" ~,'~ of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of ~'e Clle~(and their designated receplents on file In our office) and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed, and are not Indicative of the qualities of apparently Identical or similar specimens.
:'i 7(~t~ni~i ~i~i~eri~-, construction Materials Testing ·: Envi~0~ental Engih~Hr~g · con~Ul~in~~' : 11422