Town Center L4B1-LR010802ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR CONSTRUCTION MANAGEMENT GROUP DATE 08/02/01
DALLAS, TEXAS
PROJECT COPPELL TOWN CENTER OUR REPORT NO. 01612-3
COPPELL, TEXAS
TEST DATA:
TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT
NO. DATEDE PTH'"~ NUMBER MOISTURE DRY DENSITY' MOISTURE DRY DENSITY COMPACTION COMMENT*
% PCF % PCF
1 08/02/01 FG-2.0 1 15.5 101 16.2 100 99 1-A
2 08/02101 FG-2.0 1 15.5 101 16.8 99 98 1-A
TEST LOCATION:
1 15' NORTH AND 20' EAST FROM SOUTHWEST CORNER OF BUILDING PAD
2 30' NORTH AND 40' EAST FROM SOUTHWEST CORNER OF BUILDING PAD
CC; Constr. Mngt. Group; Jeff Miller. City of Coppell; La r, Daves, Lee Stone /Ip~N SU~/
1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
4. CEMENT TREATED D. RETEST
Our test results & reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed ex~ w~l express app~al of ALPHA The use
of our name & test results mu. receive our written approval. Test results & reports apply only to the samples testedand/or obsewed, and are not indicative of the cllrJal'~ie~of apparently ~llentical or similar' specimens.
Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting