Loading...
Town Center L1B3-LR 980828 Information I. To Build On '-..tie,,4n, t · Oa~el-' .. · Yesti~ REPORT OF FIELD INSPECTION OF CONCRETE TESTED FOR: MIKE MORGAN PROJECT: COPPELL TOWN CENTER LEE LEWIS CONSTRUCTION COPPEL, TX 16660 NORTH DALLAS PARKWAY DALLAS, TX 75248 DATE: August 28, 1998 OURREPORTNO.: 341-80053-24 FIELD DATA: Concrete was a 3000 psi mix delivered by REDI-MIX, mix number 718. NO. OF CONCRETE [ i TEMPERATURE. 'F SPECIMENS SUPPLIER TIME TRUCK TIME TRUCK YARDS OF AIR ....... : ...... SET NO. MADE TICKET NUMBER DISPATCHED UNLOADED CONCRETE {_ SLUMP. IN CONTENT. % AIR CONCRETE 403 4 ! 106189 02:00 am i 02:50 am 50.0 ! 4 3/4 ' 82 91 ............................. ~. ............................... ~ ....................................... ~ ......... ~ i83 ': 89 404 4 106199 ; 03:45 am 04:35 am 150.0 i 5 1/4 I LOCATION: SLAB i 403 60' NORTH X 40' EAST OF SOUTHWEST CORNER OF SLAB i 404 35' NORTH X 25' WEST OF SOUTHEAST CORNER OF SLAB NOTE: APPLICABLE AS'tM STANDARDS. UNLESS OTHERWISE INDICATED: MAKING TEST SPECIMENS: C31-91; SLUMP: C143-90a: AIR CONTENT: C231-91b; TEMPERATURE. C1064-86(93) REMARKS: TECHNICIAN: FLOYD PALMER Respectfully submitted, Professional Service Industries, Inc. THESE TEST RESULTS APPI. Y ONLY TO THE SPECIFIC SAMPI.E8 TESTED AND MAY NOT BE INDICATIVE OF ~ ENTIRE C{~ICRE'rE Pt. ACEMENT. REPORT8 MAY NOT BE REP~'OO~CED, EXCEPT IN FUU.. WITHOUT wI~rTEN F~RMISEION BY PROFE~IONAL SERVICE INOIJSTRIES. INC. PSI A-200-1 (2)F Professional Service Industries, Inc. · 4087 Shilling Way · Dallas, TX 75237 ° Phone 214/330-9211 · Fax 214/263-2612