Town Center L1B3-LR 980828 Information
I. To Build On
'-..tie,,4n, t · Oa~el-' .. · Yesti~
REPORT OF FIELD INSPECTION OF CONCRETE
TESTED FOR: MIKE MORGAN PROJECT: COPPELL TOWN CENTER
LEE LEWIS CONSTRUCTION COPPEL, TX
16660 NORTH DALLAS PARKWAY
DALLAS, TX 75248
DATE: August 28, 1998 OURREPORTNO.: 341-80053-24
FIELD DATA: Concrete was a 3000 psi mix delivered by REDI-MIX,
mix number 718.
NO. OF CONCRETE [ i TEMPERATURE. 'F
SPECIMENS SUPPLIER TIME TRUCK TIME TRUCK YARDS OF AIR ....... : ......
SET NO. MADE TICKET NUMBER DISPATCHED UNLOADED CONCRETE {_ SLUMP. IN CONTENT. % AIR CONCRETE
403 4 ! 106189 02:00 am i 02:50 am 50.0 ! 4 3/4 ' 82 91
............................. ~. ............................... ~ ....................................... ~ .........
~ i83 ': 89
404 4 106199 ; 03:45 am 04:35 am 150.0 i 5 1/4
I
LOCATION: SLAB
i 403 60' NORTH X 40' EAST OF SOUTHWEST CORNER OF SLAB
i 404 35' NORTH X 25' WEST OF SOUTHEAST CORNER OF SLAB
NOTE: APPLICABLE AS'tM STANDARDS. UNLESS OTHERWISE INDICATED: MAKING TEST SPECIMENS: C31-91; SLUMP: C143-90a: AIR CONTENT: C231-91b; TEMPERATURE. C1064-86(93)
REMARKS:
TECHNICIAN: FLOYD PALMER Respectfully submitted,
Professional Service Industries, Inc.
THESE TEST RESULTS APPI. Y ONLY TO THE SPECIFIC SAMPI.E8 TESTED AND MAY NOT BE INDICATIVE OF ~ ENTIRE C{~ICRE'rE Pt. ACEMENT.
REPORT8 MAY NOT BE REP~'OO~CED, EXCEPT IN FUU.. WITHOUT wI~rTEN F~RMISEION BY PROFE~IONAL SERVICE INOIJSTRIES. INC.
PSI A-200-1 (2)F Professional Service Industries, Inc. · 4087 Shilling Way · Dallas, TX 75237 ° Phone 214/330-9211 · Fax 214/263-2612