Town Center L1B3-LR 980817 lw,' ~' ~]I Information
'"~'~ I. To BuiM On
REPORT OF FIELD INSPECTION OF CONCRETE
TESTED FOR: MIKE MORGAN PROJECT: COPPELL TOWN CENTER
LEE LEWIS CONSTRUCTION COPPEL, TX
16660 NORTH DALLAS PARKWAY
DALLAS, TX 75248
DATE: August 17, 1998 OUR REPORT NO.: 341-80053-20
FIELD DATA: Concrete was a 3000 psi mix delivered by REDI-MIX,
mix number 718.
................ T'";~o.%F'--F-- co.c~E~E ....... r .............................. ~ ................. ~ ............. ~, ...... ~.PERATURE. °F
SPECIMENS / SUPPLIER TIME TRUCK ! TIME TRUCK i YARDS OF :: AIR '[ .............
SET NO. ~ MADE Im TICKET NUMBER DISPATCHED i UNLOADED i CONCRETE SLUM~..I_N___L-- CON__T_EN.T. ?A ! AIR"/ CONCRETE
368 ! ..... 4 51135 01: 10 pm ~ 02: 00 pm 10.0 . _4 1/2 i 98 91
.-'?_~-:i--~ ............. ~i ..................... ~ ........ _~i'"'"i ...... ~ ............. i .......................... : ........
LOCATION: GRADE BEAMS
368 GRADE BEAMS 1.0 AND 7.0
NOTE: APPLICABLE ASTM STANDARDS. UNLESS OTHER%MSE INDICATED: MAKING TEST SPECIMENS: C31-91; SLUMP: C143-90a: AIR CONTENT: C231-91b; TEMPERATURE: C1064~6(93)
REMARKS: Observed the placement of 30.0 cubic yards of concrete.
TECHNICIAN: JERRY RENFRO Respectfully submitted,
TIME: 12:00 pm - 03:00 pm ProfessionalServicelndustries, lnc.
PSN A.20~t (2)F
Professional Service Industries, Inc. · 4087 Shilling Way · Dallas, TX 75237 · Phone 214/330-9211 · Fax 214/263-2612