Town Center L1B2-LR 980810· GEOTECHNICAL ENGINEERING E · ENVIRONMENTAL CONSULTING El GEE Consultants, inc. · CONSTRUCTION MATERIALS TESTING 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 Fax (214) 352-6972 REPORT OF CONCRETE MIX INSPECTION Report Date: August 10. 1998 Date Concrete Placed: July 13. 1998 Client: Ewing Properties Project: Town Center Shopping Coppell. Texas Tri Cities Foundation Texas Industries #41 Paving Contractor: Concrete Supplier and Plant: Location of Placement: Standard 6"x12" Area 28.27 Square Inches Concrete Report No.: 23 Project No.: 298-0165 MATERIALS .~ ..... , SSD,a~h w... INSPECTION DATA Descripuon (Lbs/CuYd) Mix Number: Time Sample Batched: 11:04 am Cemem: Time Sampled: 11:50 am Sample Location: Paving - 25' W. of SE comer of building Fly Ash: Truck/Ticket No: 472/1091614 Coarse Aggregate: 1" Temperature: Intermediate Aggregate: Ambient Range: 90°F Concrete Range: 95°F Fine Aggregate: Slump Range (inches): 4lA" Admixtures: Weather Conditions: Partly Cloudy I Time Started: 07:00 am 2 Time Completed: 01:30 pm Added Water: 40 Gallons Sample Air Content (%): 4% Total Cubic Yards Placed: 270 Required Strength (Lbs./sq.in.): 3,000 Sbec.ven Measured Age Date To~.al Load Compressive Strength Remarks Number Slump (in.) (Days) Tesled (Lbs.) (Lbs./Sq,ln.) CTC 94 7 07/20/98 76,660 2,710 CTC 95 28 08/10/98 104.160 3.680 CTC 96 41/~ - 28 08/10/98 104,820 3,710 CTC 97 H HOLD T~st Mefl~ds Utilized Fracture Rcgulat Cylinders Made By: AS ASTM C-31.C-39.C-143 (Unless Noted Otherwise) Remarks and/or Distribution: * Superintendent informed of slump cc: Mr. John Maggiore - Ewing Properties Mr. Hank Quigg - Richmond Group Mr. Steve Dial - Hunt & Joiner Engineering Mr. Eric Royal - Royal General Contractors (2) Mr. Larry Davis - City of Coppell (2) ' All lelters and reports are for the exclusive uae of the client to whom they ate addressed and shall not be vtiahout the full ~ of GEE Comultan~, Inc. The use of out mune must receive out' priol' written approval. Our letters and reports apply only r~ the sample tested and/or ip.~pec~d and ate not rec~ssarily indicative of ~le quamities of aRoatel~Jy idenlicai or similar products. · GEOiECHNICAL ENGINEERING . EI GEE Consultants, Inc. 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REPORT OF CONCRETE MIX INSPECTION Report Date: August 10, 1998 Date Concrete Placed: July 13, 1998 Client: Ewing Properties Project: Town Center Shopping Coppell, Texas Tri Cities Foundation Texas Industries #41 Paving Contractor: Concrete Supplier and Plant: Location of Placement: Standard 6"x 12" Area 28.27 Square Inches Concrete Report No.: 22 Project No.: 298-0165 MATERIALS s ..... SSD ~,t~,, wa. INSPECTION DATA Description (LbslCuYd) Mix Number: 8204 Time Sample Batched: 09:02 am Cement: Time Sampled: 09:55 am Fry Ash: Sample Location: Paving - 75' W. & 25' N. of NE corner of building Coarse Aggregate: 1" Truck/Ticket No: 715/1091371 Intermediate Aggregate: Temperature: Fine Aggregate: Ambient Range: 86°F Concrete Range: 94°F Admixtures: Slump Range (inchesl: 6tA" I Weather Conditions: Partly Cloudy 2 Time Started: 07:00 am Added Water: 0 Gallons Time Completed: 01:30 pm Sample Air Content ( %): 1% Total Cubic Yards Placed: 180 Required Strength (Lbs./sq.in.): 3,000 I Measured Age Date I To{al Load Compressive Strength Remarks Number Slump {in.) (Da)~) Tested[ (Lbs.) (Lbs.lSq.ln.! CTC 90 7 07/20/98 64,340 2,280 CTC 91 28 08/10/98 84,840 3,000 CTC 92 61/2" * 28 08/10/98 88,020 3,110 CTC 93 H HOLD Test Methods Utilized Fracture Regular Cylinders Made By: AS ASTM C-31,C-39,C-143 (Unless Noted Other. vise) Remarks and/or Distribution: * Superintendent informed of slump cc: Mr. John Maggiore - Ewing Properties Mr. Hank Quigg - Richmond Group Mr. Steve Dial - Hunt & Joiner Engineering Mr. Eric Royal - Royal General Contractors (2) Mr. Larry Davis - City of Coppell (2) All letters and reports arc for the exclusive usc of the client to whom they are addressed and shnll not be reprod~ without the fidl aplnoval m GEE Comultan~, Ira. The uae of our ~ame mua~ recetve our prior written approval. Our letters and reports apply only to the sample tested and/or inspected and areql[x neceaaattly mdw. am, eot the quantities ol al~aarenl~y iderltJCal of stmdar products. · GEOTECHNICAL ENGINEERING E · ENVIRONMENTAL CONSULTING GEE Consultants Inc. E[ · CONSTRUCTION MATERIALS TESTING 0046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REPORT OF CONCRETE MIX INSPECTION Report Date: August 10, 1998 Date Concrete Placed: July 13, 1998 Client: Ewing Properties Project: Town Center Shopping Coppell, Texas Tri Cities Foundation Texas Industries #41 Paving Contractor: Concrete Supplier and Plant: Location of Placement: Standard 6"x12" Area 28.27 Square Inches Concrete Report No.: 21 Project No.: 298-0165 MATERIALS Souse? SSO Batch ~ts. INSPECTION DATA Descriptim'~ (Lbs/CuYd) Mix Number: 8204 Time Sample Batched: 07:26 am Cement: Time Sampled: 08:15 am Fly Ash: Sample Location: Paving - 90' W. & 15' N. of NE coruer of building Coarse Aggregate: [" Truck/Ticket No: 716/1091217 Intermediate Aggregate: Temperature: Fine Aggregate: Ambient Range: 84"F Concrete Range: 94°F Admixtures: Slump Range (inches): 5 th" 1 Weather Conditions: Partly Cloudy 2 Time Started: 07:00 am Added Water: 0 Gallons Time Completed: 01:30 pm Sample Air Content (%): 1.5% Total Cubic Yards Placed: 110 Required Strength (Lbs./sq.in.): 3,000 Specimen Measured Age Date To~al Load Compulsive Strength Remarks Number Slump (ill.) (Days) Tested (Lb.) 0.~./Sq. ln.) CTC ,86 7 07/20/98 74,660 2,640 CTC 87 28 08/10/98 96,780 3,420 CTC 88 5 ½" 28 08/10/98 88,480 3,130 CTC 89 H HOLD Test Methods Utilized Fracture Regular Cylinders Made By: AS ASTM C-31.C-39.C-143 IUnl~s Noted Otherwise} Remarks and/or Distribution: cc: Mr. John Maggiore - Ewing Properties Mr. Hank Quigg - Richmond Group Mr. Steve Dial - Hunt & Joiner Engineering Mr. Eric Royal - Royal General Contractors (2) Mr. Larry Davis - City of Coppell (2) All letters and reports are for the exclusive use of tim client to whom they are addressed and shall not be mprod~ ~ithout the full ql~ of GEE Consult. ams. InF. The faa of oar name mast r~etv~ our prior written approval. Our letters and reports apply only to the sample tested and/or impected and are n~:essartly tndmatlve ~' the qtJantltlus of apfmmntly idemical or similar pt"oducts.