Town Center L1B2-LR 980619· GEOTECHNICAL ENGINEERING E ' ' N¥'RON NT^L ON$ mN GEE Consultants, Inc. EI · CONSTRUCTION MATERIALS TESTING 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REINFORCING STEEL PLACEMENT Report Date: Client: Project Identification Method of Test June 19, 1998 Ewing Properties Town Center Shopping - Coppell, Tx. Reinforcing Steel Inspection Visual Inspection Test Date: June 17, 1998 General Report No.: 10 Project No.: 298-0165 Page 1 of 1 Results On June 17, 1998, reinforcing steel was inspected at the following locations: Pier Caps: A.3-1 thru K-1 There were no discrepancies. Tech: DF Mr. John Maggiore - Ewing Properties Mr. Hank Quigg - Richmond Group Mr. Steve Dial - Hunt Joiner Engineering Mr. Eric Royal - Royal General Contractors (2) Mr. Larry Davis - City of Coppel, (2, · GEOTECHNICAL ENGINEERING El. GEE Consultants, Inc. 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 ° Fax (214) 352-6972 REPORT OF CONCRETE MIX INSPECTION Report Date: June 19, 1998 Date Concrete Placed: June 12, 1998 Client: Ewing Properties Project: Town Center Shopping Coppell, Texas Tri Cities Foundation Redi-Mix/Plant/910 Panels Contractor: Concrete Supplier and Plant: Location of Placement: Standard 6"x12" Area 28.27 Square Inches Concrete Report No.: 13 Project No.: 298-0165 MATERIALS ~ree, ssD aa~. wts. INSPECTION DATA Descripnon (Lbs/CuYd) Mix Number: 645 Time Sample Batched: Time Sampled: Cement: Sample Location: Fly Ash: Truck/Ticket No: Coarse Aggregate: 1" Temperature: Intermediate Aggregate: Ambient Range: 101°F Concrete Range: 107°F Fine Aggregate: Slump Range (inches): 6~" Admixtures: Weather Conditions: Clear I Time Started: 12:30 pm 2 Time Completed: 04:00 pm Added Water: 20 Gallons Sample Air Content (%): N/A Total Cubic Yards Placed: 10 Required Strength (Lbs./sq.in.): 3,500 12:20 pm 01:10 pm Panels - # 1.3,11,13,16,17.19,21 & 24 126/102678 Specimen Measured Age Date Total Lead Compressive Strength Remarks Number Slump (in.) (Days) Tested (Lbs.) (Lbs./Sq.ln.) CTC 53 7 06/19/98 86,740 3,070 CTC 54 10 06/22/98 CTC 55 6~A" 28 07/10/98 CTC 56 28 07/10/98 CTC 57 H HOLD Test Me,hods Utilized Fracture Regular Cylinders Made By: HG ASTM C-31,C-39,C-143 (Unless Noted Otherwise} Remarks and/or Distribution: cc: Mr. John Maggiore - Ewing Properties Mr. Hank Qmgg - Richmond Group Mr. Steve Dial - Hunt & Joiner Engineering Mr. Eric Royal - Royal General Contractors (2) Mr. Larry Davis - City of Coppell (2) ve use of the chent to whom tbe are addressed and shail no~ be re rod tthout the full approval of GEE Consultants Inc Tbe use of our name must recelve A etters and reports are for thc exclasi ' y p uc~itbo ...... , . . .. . our prior written approval. Om' letters and reports apply only to the sample tested and/or respected and are not necessarily ~ndtcar~ve of the quant~ttes of apparendy ~dendcal or s~mdar products. · GEOTECHNICAL ENGINEERING E GEE Consultants, Inc. 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REPORT OF CONCRETE MIX INSPECTION Report Date: June 19, 1998 Date Concrete Placed: May 21, 1998 Client: Ewing Properties Project: Town Center Shopping Coppell, Texas Tri Cities Foundation TXI #41 Slab Contractor: Concrete Supplier and Plant: Location of Placement: Standard 6"x12' Area 28.27 Square Inches Concrete Report No.: 10 Project No.: 298-0165 MATERIALS s ..... , ssD ~t~, wu. INSPECTION DATA Description (Lbs/CuYd) Mix Number: 9506 Time Sample Batched: Cement: Time Sampled: Fly Ash: Sample Location: Coarse Aggregate: Track/Ticket No: Intermediate Aggregate: Temperature: Fine Aggregate: Ambient Range: 94°F Concrete Range: 91°F Admixtures: Slump Range (inches): 5~ I Weather Conditions: Hazey 2 Time Started: 01:30 pm Added Water: 0 Gallons Time Completed: 03:15 pm Sample Air Content (%): N/A Total Cubic Yards Placed: 20 Required Strength (Lbs./sq.in.): 3,000 01:57 pm 02:30 pm 125' W. of Y up on SE Retainer Wall(From East fire hydram) 806/1056834 I Specimen Measured Age Date I Total Load Compressive Strength Remarks Number Slump {in.) iDaysi Tested] (Lbs.) (Lbs./Sq. ln.) CTC 41 7 05/28/98 91,500 3,240 CTC 42 28 06/18/98 136,740 4,840 5" CTC 43 28 06/18/98 133,340 4,720 CTC 44 H HOLD Test Metheds Utilized Fracture Regular Cylinders Made By: DF ASTM C-3l.C-39,C-143 (Unless No,ed Otherwise) Remarks and/or Distribution: cc: Mr. John Maggiore - Ewing Properties Mr. Hank Quigg - Richmond Group Mr. Steve Dial - Hunt & Joiner Engineering Mr. Eric Royal - Royal General Contractors (2) Mr. Larry Davis - City of Coppell (2) ram comm.l, tant., lac. All letters and reporu are tor the exclusive usc of the client to whom they are addressed and shall not be ~thout the full approval of GEE Consultants, Inc. The ~e of our name must ~ce~ve our prior written approval. Our letters and reports apply only to the sample ms[ed and/or mpectnd and are not r/:ceasla'ily ~ndicative of the quantities of apparently ident~ual of similar producte.