Loading...
Town Center L1B2-LR 980618· GEOTECHNICAL ENGINEERING E I ·ENVIiONMENTALCONSULTING GEE Consultants, Inc. 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REPORT OF IN-PLACE DENSITY AND MOISTURE OF SOIL Density Repo~'t No. 21 (298-0165) Method: ASTM D2922 D3017 D698 Page of 1 Client: Ewing Properties Material Description Maximum Optimum Dry Moisture Density Content Prqiect: Town Center Shopping-Coppell (Lbs/CuFf) Percent 1. Olive Gray Clay 103.2 17.6 2. Reddish Brown Sandy Clay 99.6 18.4 Test Date: June 17, 1998 3. Brown & Yellowish Brown Silty Clay 98.2 17.8 4. Yellowish Brown Clayey Sand (select fill) 115.0 11.5 5. Brown Clayey Sand (Ihne treated) 93.2 20.6 Report Date: June 18, 1998 Required Density (%): Min. 95% Required Moisture (%): Opt -t-2% Mat Location/Elevation (and/or) Lift In-Place In-Place Percent No. Dry, Density Moisture Compaction Test (Lbs/CuFf) Content (%) No. Probe Depth 5 Retest//57 58 100' W. & 60' S. of NE property line corner 91.1 20.7 97.6 6" Test did meet project specifications cc: Mr. John Maggiore - Ewing Properties Mr. Hank Quigg - Richmond Group Mr. Steve Dial - Hunt & Joiner Engineering Mr. Eric Royal - Royal General Contractors (2) Mr. Larry Davis - City of Coppell (2) 0{~~ Our letters and reports are for the exclusive use of the client to whom they are addressed. The use of o~nJm/~l~must receive our prior written approval. Our letters and reports apply only to the sample tested and/or inspected, and are not necessarily indicative of the quantities of apparently identical or similar products.