Loading...
Town Center L1B2-LR 980414o GEOTECHNICAL ENGINEERING EI · CONSTRUCTION MATERIALS TESTING 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-$433 · Fax (214) 352-6972 REPORT OF IN-PLACE DENSITY AND MOISTI.R OF SOIL Density Report No. 1 (298-0165) Method: ASTM D2922 D3017 D698 Page 1 of 1 Client: Ewing Properties Material Description ,Maximum Op0raum Dry Moisture Density Contain Project: Town Center Shopping-Coppell (Lbs/CuFO Perccm 1. Olive Gray Clay 103.2 17.6 Test Date: April 8, 1998 :. Reddish Brown Sandy Clay 99.6 18.4 3. Brown & Yellowish Brown Silty Clay 911.2 17.$ Report Date: April 14, 1998 Required Density (%): Min. 95% Required Moisture (%): Opt +5% Mat Location/ElevattOn (and/or) Lift In-Place In-Place Perccm No. Dry Density Moisture Compaction Test (Lbs/CuF0 Content (%) No. Probe Depth 3 Subgrade, Southwest Portion i 10' W. & 20' S. of NE corner or' building 87.6 28.0* 89.2* 6" 3 Subgrade, Southwest Portion 2 100' W. & 15' N. of SE corner of building 88.8 24.9* 90.4* 6" Test does not meet project st ons cc: Mr. John Maggiore - Ewing Properties Mr. Hank Quigg - Richmond Group Mr. Steve Dial - Hunt & Joiner Engineering Mr. Eric Royal - Royal General Contractors Mr. Larry Davis - City of Coppell (2) Our loners and reports are for the exclusive usc of the client m whom they arc addressed. Thc use of our name must receive our prior written approval. Our letters and reports apply only to the sample tested and/or inspected, and arc not necessarily indicative of the quantifies of apparently identical or similar products.