Loading...
Valley R Baptist-LR 940908Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: 94.1021 CLIENT: Valley Ranch Baptist Church DATE: 8 September 1994 PROJECT: Valley Ranch Baptist Church Phase I, Coppell SUPPLIER: Pioneer LOCATION OF POUR SET 1: Sidewalks. Cylinders made on sidewalk directly south of the south building entrance LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. Truck No. 130 Cement Ticket No. 282108 Flyash Time Batched 8:04am Sand Time Sampled 8:40am in. Concrete Temp. (ASTM C1064) 89°F 1.0 in. Air Content (ASTM C231) 5.2% Water Unit Weight (ASTM C138) Admix #1 Admix #2 AEA COMPRESSIVE S TRENG TH TES TS (ASTM C39) Cylinder Slump Age Test Number Inches Days Date (ASTM C1 4700 (Standard 6 inch x 12 inch cylinder) Total Load Compressive Required Pounds Strength 28-Day psi Strength 129 6.00 7 09/15/94 130 6.00 7 09/15/94 131 6.00 28 10/06/94 132 6.00 28 10/06/94 86,300 3050 84,200 2980 28-Day ~verage 3000 TECHNICIAN: DISTRIBUTION: RDG (8:00am-9:30am) (1) Valley Ranch Baptist Church, Bob Arnold (1) Urban Architecture, Betsy del Monte (1) Brockette-Davis-Drake, Inc., Allen Lowes (2) Dal-Mac Construction, Scotty Eoff (1) City of Coppell, Garreth Campbell 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: 94.1021 CLIENT: Valley Ranch Baptist Church DATE: 8 September 1994 PROJECT: Valley Ranch Baptist Church Phase I, Coppell SUPPLIER: Pioneer LOCATION OF POUR SET 1: Sidewalks. Cylinders made on sidewalk directly south of the south building entrance LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. Truck No. 130 Cement Ticket No. 282108 Flyash Time Batched 8:04am Sand Time Sampled 8:40am in. Concrete Temp. {ASTM C1064) 89°F 1.0 in. Air Content (ASTM C231) 5.2% Water Unit Weight (ASTM C138) Admix //1 Admix //2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39i Cylinder Slump Age Test Number Inches Days Date (ASTM C143) 4700 (Standard 6 inch x 12 inch cylinder) Total Load Compressive Required Pounds Strength 28-Day psi Strength 129 6.00 7 09/15/94 130 6.00 7 09/15/94 131 6.00 28 10/06/94 132 6.00 28 10106/94 86,300 3050 84,20O 2980 110,100 3900 106,700 3770 28-Day Average 3840 3OOO TECHNICIAN: DISTRIBUTION: RDG (8:00am-9:30am) (1) Valley Ranch Baptist Church, Bob Arnold (1) Urban Architecture, Betsy del Monte (1) Brockette-Davis-Drake, Inc., Allen Lowes (2) Dal-Mac Construction, Scotty Eoff (1) City of Coppell, Garreth Campbell 2870 Walnut Hill Lane Dallas, Texas 75229 (214). 351-6419 Fax (214) 351-5148