ST9601-SP 990315ETI Extrusion Technologies, Inc. " VINYL-LOCK 900" DR 14 & 18 APPROVED [ AWWA - C- 900 - DR'S 25 - 18 - 14 FOR MUNICIPAL WATER APPLICATIONS Short Form Specification Scope Physical Requirements This specification designates general requirements Standard Laying Lengths: Standard laying lengths for unplasticized Polyvinyl Chloride (PVC) Plastic shall be 20 ft. (-+- 1 ") for all sizes. At least 85% of the Municipal Water Pipe with integral bell and spigot total footage of pipe of any size shall be furnished in joints for the conveyance of water and other fluids. standard lengths. The remaining 15% in random lengths. Random lengths shall not be less than 10 feet long. Materials Hydrostatic Test: Each standard and random Pipe shall meet the requirements of AWWA C900 lengthofpipeshallbetestedtofourtimesthedesign "Polyvinyl Chloride(PVC) Pressure Pipe". Class 150 pressureofthepipeforaminimumof5seconds. The pipe shall conform to the requirements of DR 18, integral bell shall be tested with the pipe as Class 1'00 pipe shall conform to the requirements of contained in the table below DR 25 & Class 200 pipe shall conform to the requirements of DR 14. Class 1 O0 -- DR25 -- 400 psi Class 150- D1~18 -- 600 psi Class 200-.DR14 .-- 800 psi Standards Quick Burst Test: Randomly selected samples tested in accordance with ASTM D1599 shall AWWA C900 -- Polyvinyl Chloride (PVC) pressure pipe 4" through 12" for water. withstand without failure pressures listed below ASTM D1784 -- Specification for Polyvinyl Chloride when applied in 60-70 seconds. (PVC) compounds. Class 1 O0 -- DR25 -- 535 psi ASTM D3139- Joints for plastic pressu re pipe using Class 150 -- DR liEi -- 755 psi elastomeric seals. Class 200 -- {SR1,1 '-- 985 psi ASTM F477 -- Specification for elastomeric seals. Pipe Stiffness: The pipe stiffness using UNI-B-1 -- Thermoplastic pipe joints, pressure and for PVC Municipal Water Pipe is contained in the non-pressure applications. Table below: UNI-B-3 -- Installation of Polyvinyl Chloride (PVC) pressure pipe (complying with AWWA standard C- Class 1 O0- DR25- F/Ay- 129 900). Class 150 -- DR1R -- F/Ay - 364 UNI-B-8 -- Direct tapping of PVC pressure water Class200- DR14- F/Ay-815 pipe. Pipe Agency Listings Underwriter's Laboratory- UL All pipe shall be suitable for use as a pressure conduit. Provisions must be made for expansion and Factory Mutual -- FM contraction at each joint with an elastomeric ring. National Sanitation Foundation The bell shall consist of an integral wall section with UNI-BELL PVC Pipe Association an elastomeric ring which meets*the requirements of ASTM F-477 standard specification for elastomeric seals (gaskets for joining plastic pipe.) The wall thickness in the bell section shall conform to the requirements of ASTM D-3139. Sizes and dimensions shall be as shown in the standards cited in this specification. When used for potable water systems pipe shall meet the National Sanitation Foundation Standard No. 14. The pipe shall be manufactured to cast iron or ductile iron outside dimensions in accordance with AWWAoC900. PIPE DIMENSIONS & WEIGHTS T2 TI ~ o.o. //~////~ ///////' PIPE PIPE THICKNESS (MIn.) POUNDS OUTSIDE INSIDE R"iNG STOP NOMINAL DIAMETER DIAMETER BARREL SOCKET GROOVE MARK ' SIZE DR O.D. I.D. T1 T= Ta z WT. / FT. WT. / JT. 4 25 4.80 4.416 .192 .207 .192 4.125 1.80 36.0 4 18 4,80 4.266 .267 .298 .267 4.125 2.50 50.0 4 14 4.80 4.114 .343 .394 ,343 4.125 3.10 62,0 6 25 6.90 6.348 .276 .300 .276 5.125 3.75 75.0 6 18 6.90 6.134 .383 .429 .383 5.125 5.12 102,4 .,~,6 14 6.90 5.914 .493 .567 .493 5.125 6.49 129.8 8 25 9.05 8.326 .362 .395 .362 6.500 6.61 132.28 8 18 9.05 8.044 .503 .562 .503 6.500 8.89 177.8 '~ 14 :? 9.05 7.758 .646 .743 .646 6.500 11.25 225.0 10 25 11.10 10.212 .444 .483 .444 6.875 9.78 195.6 ,10 18 11.10 9.866 .617 .690 .617 6.875 13.47 269.4 10 14 11.10 9.514 .793 .912 .793 6.875 17.00 340.0 12 25 13.20 12.144 .528 .574 .528 8.000 13.9 278.0 12 18 13.20 11.734 .733 .820 .733 8.000 19.0 380.0 12 14 13.20 11.314 .943 1.085 .943 8.000 24.2 484.0 E Fu. Techno/og/es, Inc. 1600 Stout Street · Suite 1710 · Denver, Colorado 80202 · (303)893-1101 · Telefax (303)893-4140 · Telex RCA 296423 ETEC UR CO18 Rev. 5/89 'r