Magnolia Village-LR011026 ALPHA TESTING, INC.
Concrete
Test
~09 Wisconsin St.. Suite 10 ~omt, ress,on
Dallas, Texas 75229 -De"er*
(972) 620-8911
Tested For: CONSTRUCTION MANAGEMENT GROUP Our Report No.: 01614-24
ATTN: MR. JEFF MILLER Issue Date: 10/26/2001
5207 MCKINNEY AVENUE, SUITE 12
DALLAS, TX 75205
Fax Number: (214) 521-1279
Project Desc: MAGNOLIA RETAL
651 N. DENTON TAPP-- COPPELL, TX
FIELD DA TA
Placement Location: PIERS: LINE D-9, 10.11, 12, 13; C-14; LINE A-14, 12, 1, 3, 6
Date Placed: 9/17/01 Plant Number: FA-5 SK
Time Placed: 3:30 PM Delivery Ticket No.: 30879
Slump (ASTM C-143): 5" Made By: ALPHA
Air Content: NA Cured Specification: ASTM C-31
Air Temperature: 90
Specimen Temperature: 91
Date Received: 9/18/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: VICORS, VICTOR
Mix Data Submitted By: IMAGE
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI:
17 LAB C-1231 9/24/01 7 12 N/A 6 28.27 71362 2520
18 LAB C-1231 10/15/01 28 12 N/A 6 28.27 85970 3040
19 LAB C-1231 10/15/01 28 12 N/A 6 28.27 85640 3020
20 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3000
Results to Date: PASS
Notes:
CC: CITY OF COPPELL, CITY OF COPPELL, CONSTRUCTION MANAGEMENT GROUP
Respectfully Submitted By: of Alpha Testing, Inc. -
with expre~ approval of AEPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed, and are not Indicative of the qualities of apparently Identical or similar specimens.