ST0004-LR011005 TERRA-MAR, INC.
GEOTECHNICAL ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON LONGVIEW AUSTIN
050 Ables Lane, Dallas, Texas 75229 Phone:972-488-8800 Fax:972-488-8080
SIEVE ANALYSIS OF ROAD MIXED MATERIALS
TEST METHOD: TEX 101E
CLIENT: The City of Coppelt DISTRIBUTION:
PROJECT: Freeport Parkway (1) The City of Coppell
REPORT DATE: 10/05/01
TMI REPORT NO.: DC01-066-063
Page 1 of 1
Test Method: TEX 101E Date Tested: 10/02/01
Min % Passing 1-3/4" Sieve ]00% Technician: M. Kashem
Min % Passing #4 Sieve 60% Stabilizing Agent: Lime
South bound lane, Freeport Parkway -
1 45' North of Minyard's wr,rehouse 100% 65.6%
2 at Station 2+50, 70' South from rail track 100% 63.5%
3 65' South from Fritz Dr. 100% 68.2%
4 100' North from Lucent Technoligies building 100% 63.0%
Specification: NCTCOG 4.6.4 100% 60.0%
REMARKS:
,.,.; ....... ;...: .......
'~"¢0"':"4~4'~' t~'~-.~4'11~;¢ '/~t M/15ettit(, P.E. /
'~'¢O~A~- ~__~" ~/Sr. Vice President
Note: this report is t'or the exclusive usc o~'the c]~c~t addressed. This report may net be r(~produced c×cet h~ it's elltiTet¥, without
the written consent ct' TM]. P~esn]ts ap])l¥ to above tests only.
~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080
- In-Place Soil Moisture/Density Tests by Nuclear Method
Client: The City of Coppell Report Distribution: (1) The City of Coppell
Project: Freeport Parkway Pavement
Repair
TMI Report No.: DC01-066-062
Report Date: 10/05/2001
Specifications Test Data
Percent Compaction: +95% min Date Tested: 10/01/2001
Moisture Content: opt -2% to +4% Technician: Mohammed A. Kashem
Optimum Maximum Dry
Curve No. Test Method Material Description Moisture % Density pcf
8091 ASTM D-698-A Brown Clay treated with Lime 32.5 86.5
Test Elevation Ref. Probe Percent Wet Density Dry Density Percent
No or Lift Location Curve Depth Moisture (pcf) (pcf) Density
Freeport Parkway -
1.0 Grade South bound at Station 11 +00 8091 6" 33.7 111.8 83.6 96.6
Test results on this report meet project specification.
Test Method(s): ASTM D-2922, ASTM D-3017
Gauge: Troxler Gauge SN: 5429 Std. Density Count: 2451 Std. Mo~,s u~ou~_ ~.~
TERRA-MAR, INC.
Sr. V'm~ Prosident
The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of
this report, or any part therein, is strictly prohibited without the express written consent of TMI.
07SSD Page 1 of l