Loading...
ST0004-LR011005 TERRA-MAR, INC. GEOTECHNICAL ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON LONGVIEW AUSTIN 050 Ables Lane, Dallas, Texas 75229 Phone:972-488-8800 Fax:972-488-8080 SIEVE ANALYSIS OF ROAD MIXED MATERIALS TEST METHOD: TEX 101E CLIENT: The City of Coppelt DISTRIBUTION: PROJECT: Freeport Parkway (1) The City of Coppell REPORT DATE: 10/05/01 TMI REPORT NO.: DC01-066-063 Page 1 of 1 Test Method: TEX 101E Date Tested: 10/02/01 Min % Passing 1-3/4" Sieve ]00% Technician: M. Kashem Min % Passing #4 Sieve 60% Stabilizing Agent: Lime South bound lane, Freeport Parkway - 1 45' North of Minyard's wr,rehouse 100% 65.6% 2 at Station 2+50, 70' South from rail track 100% 63.5% 3 65' South from Fritz Dr. 100% 68.2% 4 100' North from Lucent Technoligies building 100% 63.0% Specification: NCTCOG 4.6.4 100% 60.0% REMARKS: ,.,.; ....... ;...: ....... '~"¢0"':"4~4'~' t~'~-.~4'11~;¢ '/~t M/15ettit(, P.E. / '~'¢O~A~- ~__~" ~/Sr. Vice President Note: this report is t'or the exclusive usc o~'the c]~c~t addressed. This report may net be r(~produced c×cet h~ it's elltiTet¥, without the written consent ct' TM]. P~esn]ts ap])l¥ to above tests only. ~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080 - In-Place Soil Moisture/Density Tests by Nuclear Method Client: The City of Coppell Report Distribution: (1) The City of Coppell Project: Freeport Parkway Pavement Repair TMI Report No.: DC01-066-062 Report Date: 10/05/2001 Specifications Test Data Percent Compaction: +95% min Date Tested: 10/01/2001 Moisture Content: opt -2% to +4% Technician: Mohammed A. Kashem Optimum Maximum Dry Curve No. Test Method Material Description Moisture % Density pcf 8091 ASTM D-698-A Brown Clay treated with Lime 32.5 86.5 Test Elevation Ref. Probe Percent Wet Density Dry Density Percent No or Lift Location Curve Depth Moisture (pcf) (pcf) Density Freeport Parkway - 1.0 Grade South bound at Station 11 +00 8091 6" 33.7 111.8 83.6 96.6 Test results on this report meet project specification. Test Method(s): ASTM D-2922, ASTM D-3017 Gauge: Troxler Gauge SN: 5429 Std. Density Count: 2451 Std. Mo~,s u~ou~_ ~.~ TERRA-MAR, INC. Sr. V'm~ Prosident The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. 07SSD Page 1 of l