Loading...
ST0004-LR011002 (2)~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080 ? - Concrete Compression Test Report Client: The City of Coppell Report Distribution: (1) The City of Coppell Project: Freeport Parkway Pavement (1 Quantum Contracting Repair TMI Report No.: DC01-066-054 Report Date: 10/02/2001 Specifications Test Data Strength 4000 psi @ 28 Days Placement Date 09/25/2001 Slump 5 in max Sampled By Contractor Air Content 3 % min 6 % max Weather Clear Concrete Temperature n/a Supplier/Mix Hanson/ Ambient Temperature n/a Air Content Method ASTM C-231-B Ticket Number: n/a Time Batched: n/a Time Sampled: n/a Slump: n/a Air Content: n/a Unit Weight: n/a Concrete Temperature: n/a Ambient Temperature: n/a Yardage (c.y.): n/a Placement Location: Paving, South bound lane, Freeport Parkway Sample Location: Hole #24 Cylinder Age Max Load Area Strength Fracture Set Test Date (days) (lbs. force) (sq.in.) (psiJ Type I 09250101 10/02/2001 7 120390 28.27 4260 unbonded cap I 09250102 10/23/2001 28 I 09250103 10/23/2001 28 I 09250104 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. CONTRACTOR MADE TERRA-MAR, INC. Si ~m~r~id~t The results presented in this repo~ pe~ain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this mpo~, or any pad therein, is strictly prohibited without the express written consent of TMI. O[SSD Page Iofl