ST0004-LR011002 (2)~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080
? - Concrete Compression Test Report
Client: The City of Coppell Report Distribution: (1) The City of Coppell
Project: Freeport Parkway Pavement (1 Quantum Contracting
Repair
TMI Report No.: DC01-066-054
Report Date: 10/02/2001
Specifications Test Data
Strength 4000 psi @ 28 Days Placement Date 09/25/2001
Slump 5 in max Sampled By Contractor
Air Content 3 % min 6 % max Weather Clear
Concrete Temperature n/a Supplier/Mix Hanson/
Ambient Temperature n/a Air Content Method ASTM C-231-B
Ticket Number: n/a Time Batched: n/a Time Sampled: n/a
Slump: n/a Air Content: n/a Unit Weight: n/a
Concrete Temperature: n/a Ambient Temperature: n/a Yardage (c.y.): n/a
Placement Location: Paving, South bound lane, Freeport Parkway
Sample Location: Hole #24
Cylinder Age Max Load Area Strength Fracture
Set
Test Date (days) (lbs. force) (sq.in.) (psiJ Type
I 09250101 10/02/2001 7 120390 28.27 4260 unbonded cap
I 09250102 10/23/2001 28
I 09250103 10/23/2001 28
I 09250104 Hold
Normal cylinder size: 6" x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231.
CONTRACTOR MADE
TERRA-MAR, INC.
Si ~m~r~id~t
The results presented in this repo~ pe~ain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of
this mpo~, or any pad therein, is strictly prohibited without the express written consent of TMI.
O[SSD Page Iofl