Loading...
Switching Sta-CS 890213"~]ELECTRIC February 13, 1989 Ms. Shohre D~neshnmnd Civil Engineer City of Coppell P. O. Box 473 Coppell, Texas 75092 Dear Ms. Daneshmand: I am su~nittin~ a preliminary application and Special Use Permit (SUP) for the building permit for our Droposed 138 kV electric substation to be constructed on the northwest comer of the intersection of Thweatt Road and Coppell Road in Coppell, Texas. I ~m also including fifteen (15) copies of our preliminary plat, site, and landscape plans for your review. In addition, I am attaching TU Electric checks in the 8mounts of $104.00 and $217.03 to cover the preliminary plat smd Special Use Permit (SUP), respectively. Your assistance with this impertant project to provide a continued reliable and adequate supply of electric energy to our customers in Coppell is appreciated. Very truly yours, Mark Carpenter, Supervisor Substation Engineering WMC/RST:jas Attachments cc: Mr. Ricky Eads - TU, Farmers Branch 1511 Bryan Street P.O. Box 660268 Dallas, Texas 75266-0268 4o CITY OF COPPELL SUBDI¥1S1ON APPLICATION Date Subdivision Name Copp~ll .Switchin~ Station Preliminary, Plat . ~ --~- -- - .~ Applican~ TU Electric - TP&L February 14 89 _, 19 Address 1511 Bryan St. Street Phone ] (2143 954-~70 Firm'Preparing Plat TU Electric - TP&L Address Same as Above · ' * Street. Dallas TX 75201 City S ca ce .Zip .Phone 5. Property Owner. TU Electric - TP&L · Address Same as above · Street Phone ] Developer TU Electric - TP&L City Sta.?e Zip Address Same as above Phone I .. Street ' City S~a:e '" Zip All Correspondence relative, to this app~£cation should be directed to whom: ' ' '' Nam'e Roy S~ Turner Address ! %11 Rrym9 ~t, Dallas. TX 7~2Q] <214) 954-5570 City, State, .' Zip Phone I 'General Location of Property ConDell ~Qa~ northwest corner of Thweatt Road and What is the present Zoning Dis~rict? LI Are'you requestfnq any :oning change? .yes I~ yes, what is the Case File No~? Zoning district requested? LI,-~ . Lnnd Use ......... Dup ) ex : .. "Condominium ispeci~Y .Propose~ Subdivi~ion Contains: 1~o. of Lots or Units Ac~es (tot each use) ~'NER' CITY OF COPPELL 6. 7. 9. 10. 11. I2. l~. · 17. L DEVELOPER'S CHECKLIST PRELIMINARY PLAT AND PLANS: A. Complete all parts of the official subdivision application form ........... D B. Pay appropriate filing fee: Preliminary Plat-S100 plus $4.00 per lot._~ C. Submit twenty-twl (ZZ) folded prints of the preliminary, plat and plans scale of 1' =.100' or larger on sheet size 24' x 36". .................. L ........Il D. Submit twenty-two (ZZ) folded prints of the site-plan of the proposed development .................................................................................. J] E. Submit one (1) 8~t" x 11' print of both the preliminary plat and site plan ............................................................................................... ]] F. Submittal shall include a letter of transmittal requesting review ....... ~ G. Prints of t.he !nre. liminary plat and plans shall contain the following information: I. 'Preliminary Plat" title .......................... . .............................. ~ 2. Name of the proposed subdivision ............................................ n' 3. blame and address of she subdivider ........................................... 4. Name and address of the Engineer or Surveyor responsible for design or survey ................................................................................ ~j~ Tract designation and o~her descriptions according to :.he abstract and survey records of Dallas County, Texas ............................................ ~ ]~orth point, scale and date .............................................. ~ Boundary line of the trac~ .................................................... ~ The names of adjacent subdivisions or names of record of owners of adjoining parcels. ..... .~ 'The location, widths and names of all exis~inE proposed or platted ~ree:s, easemenr, s or or. her public ways within or ad,scent ~o r. he ~rac:-- ...... v Exi~ing railroad right-of-way .............. o Section lines, political subdivisien or corporate limir, s ~ud school district · boundaries ...... ~ All parcels of land intended ~o be dedicated for public use or reserved in the deeds for the use of all property owners i~ the proposed subdivision .to~ether wir. h the purpose or conditions of li-"~izations of such reservation ..... Is 13. Existing zoning of si~e and surrounding prop~_.--~ ................. 14. Layout, ~umbers and approximate dimensions of proposed lor~ and all building lines ........... 15. Location of proposed screening walls .................. : ..... -7 .....1~ Topography of r. he site (intervals of $ feet or less, referr~li zo sca1 level U, The pl~ shall show exi~,,ing ~ruct'ures; utLlizies, sewe.--~, water ma~, · ~lve~, ~d o~er ~d~rgro~d ~c~r~ ~ the ~ ~d ~med~zel~ adjacen~ ~here~o wi~ pi~ s~ Prelim~a~ p~ of proposed wa~er d~rib~ion ~em, ~ size ~d off size drayage improvemcn~ If the a~lic~t is ~quest~g ~ v~ces ~o the Sub~o= ~ce he m~t submit a lett~ ~e~fic~y outlining ~e~ive ~quests ............................................. ~e applic~t m~t submit ~wen~-~wo (ZZ) fo~ ~ts of the concept~ pl~ of the req~ed l~dscaping w~ch sh~ c~f~ ...... ' to the ~del~es established ~ the approved '"' "P~ELLMINARY PLAI .D PLANS: CONTINUED ' PAGE 2 For residential and non-residential subdivisions where the landscaping occurs in common areas to be maintained by a property owners association, this plan shall included: 1. Edge treatment along major and minor arterials and collectors ......... 2. Subdivision entry features ............................................................... 3. Screening wall locations ................................................................. After review by the City Staff, the applicant shall make all corrections requested of him by the City Engineer ................................................................... checklist is only a supplement-to the current Subdivision Ordinance. It 'is the appliCaat's ~sponaibilit], to review and comply with the.requirements of the curr,-nt .Subdivision Ordinamce. L Sli-~ !mLAN REOUIREMENTS Prints of the site ]plan shall contain the following information all one 24" x 36" sheet ( submit twenty-two (ZZ) folded prints and one (1) BM" x 11" print). 1. Property dimensions of the site and approximate distance to nearex~ cross street; ~. All existing or proposed buildings on the property, existing s:ruc~ur~ and fire lane and access easemenls adjacenl to ~he pro~rty, and access · ' ~he proper~y; 4. All exi~in~ private and public streets including s:ree~ widths, med~ openings, ~d - . . ~. Proposed ~rcas of dedi~ion , ff neces~, including ~treets, alley~ or easemen~; ~. Po~ of ingress and egress to ibc prope~y including design and s~c~g of'driveways; 7. Parkin~ area' includin~ number ~d layou; of space, a~le witch, ~ba~e pick-up lo~:ion, fir~ l~e~, and ~y~s of ~urface of fire ~. Screened walls ant lo~:ion, ~ype of screening wall, el:her livinE or masonry. ~' hdi~le a~ areas 1o ~ ~ds~ped, r~e of landscaped, ~d lotal smuare foozle of .... , l~ds~ped are~; do ~o~ use '~ree ~m~ ; ' · hydr~, m~hol~, ~d other appu~e~c~ or s~ruc:ur~ shown. · .- 12. A~ proposed or e~ wa:er ~d sewer conne~ions, m~r locations, s~e of meres, · - wi~ me,er ~d/or de~ec~or chc~ valve vaults ~di~ed; 13. F~h~ floor elevation 0f propped or exi~ ~ruc~ures on 14.. E~t ~d proposed conlours of lhe' ~rac~ ~' inlcrvals of one foot or less, refer~nc~ !~. Proposed or e~ on ~d of/-~le ~le~; culve~ or other drayage sl~ures;' .-~. . ~ ' ~e fonow~ ~o~a:ion should ~ submt~ed ~ no,es on ~he si~e pl~ ~ ~: ". .' . ~ Proposed ~e of ~e'si~e ~r bufld~g~ ' ' " - C. $~e of buildmg (s~uare foo~a~c)[ ~ Number of liv~g uni~, by numar of ~drooms, M appli~bl~ . F. Calcu~tion of ~he ~rk~ spac~ required ~d provide~ Revised: 6-17 $7 **MUST RETv~N ALL SIX PAGES OF THIS APPLICATION CITY OF COPPELL ZONING APPLICATION 214-462-0022 A: Requesting: Description & Location of Property: Survey & Abstract: John E. Holland Sur. A-614 Specific Use Permit [X] Bo 1. 2. Addition Name (if applicable): Coppell Switchin8 Station 3. Lot & Block (if applicable): 4. Total Number of Acres: 3.4070 5. Location further described: Northwest corner of Thweatt Road and Coppell Road C. Zoning Requested: Present Zoning Proposed Zonin~ Dwelling Floor Area Classifi- Gross Net* Classifi- Gross Net* Units/Acre (Non-Reaid. cation Area Area cation Acres Acres (Resid.Only) Uses Only) "L.I. L.I~S~P~ *Excludes major & secondary thoroughfares. D. Reason(s) for Zoning Change (please be specific): switching station E. Fee: I (We) hereby.certify that the application fee, $ 217.03 , to cover the cost of this zoning application, has been paid to the City of Coppell'on Feb. ~4 , 19 89. Further, I (We) hereby authorize the City of Coppell and its employees, to ente--~ upon the premises herein above described at all reasonable times for the purpose of erecting, maintaining, or removing signs to notify the public of the pending zoning application and/or public hearing concerning said application. I (We) release the City of Coppell and its employees from liability for any damages which may be incurred to my (our) property in the erecting, maintaing, or removal of said signs. rate: 02/14~89 Representative: Roy S. Turner Owners Signature?~ Telephone ~: 954-5570 Owners Name: ~ ~lectric Address: 1511 Bryan Dallas, TX 75201 CITY OF COPPELL DEVELOPER'S CHECKLIST 1. ZONING REQUEST: A. Complete all parts of the official zoning application form ............ B. Pay appropriate filing fee: 1. Zoning - $100 plus $6.00 per acre ................................. .[1 Do Eo .[1 2. Zoning appeal - $100 plus $5.00 per property owner notified ........ 3. Land Study - $100 plus $1.00 per acre (for annexations) ............ 4. Concept Plan - $100 when submitted separately with a zoning request n/c when submitted with zoning request (for PD requests) ........... 5. Site-Plan/Mutil-Family - $100 plus $6.00 per unit (PD requests) .... 6. Site-Plan - Other - $100 (for PD requests) ......................... 7. Specific Use Permit (SUP) - $200 plus $5.00 per acre ............... Submit twenty-two (22) folded prints of the zoning exhibit drawn at a scale one inch equals 200 feet or larger on sheet 24" X 36" ............ [ ] Submit twenty-two (22) folded prints of the site plan of the proposed development on sheet size 24" X 36" .................................... [ ] Submit one (1) 8½" X 11" print of both the zoning exhibit and site plan[ ] Prints of the zoning exhibit will contain the following information all on one sheet: I. "Zoning Exhibit" title ............................................. [ ] 2. Map of property to be zoned and all property located within 200 ft.~] 3. Name and address of applicant and/or owner ......................... ~] 4. Name and address of certified surveyor ............................. [)~ 5. Name and address of person preparing the exhibit ................... ~] 6. North point, scale and date ........................................ [~ 7. Accurate location map in the upper right or left hand corner ....... [~(~ 8. Survey and abstract with tract designation ......................... ~] 9. Current and proposed zoning of the site ............................ [~ 10. Current zoning of property located within 200 ft. of the site ...... [~] 11. Names of owners of unplatted land within 200 ft. of the property to be zoned ........................................................... [ ] 12. Location and right-of-way of existing and planned major and secondary thoroughfares located within or adjacent to the subject property...~] 13. Gross and Net acreages of the requested zoning ..................... [~ 14. Potential number of dwelling units for residential zoning requests.[ ] 15. Potential square footage of building space for commercial, office, retail, and industrial zoning requests ............................. [~ 16. Location of existing right-of-way utility aua/o~ drainage easements[ ] 17. Topography and flood plain designation ............................. [~ 18. Aircraft Noise Zone designation (if applicable) .................... ~ 19. Detailed legal description of property ............................. [~] This checklist is only a supplement to the. current Zoning Ordinanca. It is the applicant's responsibility to review and comply with the requirements of the current ZoningOrdinance. [2] · In all instances where the applicant proposes to modify, delete or add to any of the standard regulations of a requested zoning district, a complete and detailed list of the changes shall be submitted .......... [ ] If the applicant is requesting a "PD" Planned Development District he must comply with the additional requirements outlined in the Zoning Ordinance ............................................................. [ ] The applicant shall place a zonin~ chan~e si~n, provided by the City, in a highly visible location on the site. The sign must be in position ten (10) days prior to P & Z consideration and then returned to the City within twenty-four (24) hours after City Council consideration ........ [ ] J. If the applicant is requesting a Special Use Permit (SUP) he must comply with the additional requirements outlined in the Zoning Ordinance ..... K. After review by the City staff, the applicant shall make all corrections requested of him by the Administrative Assistant ...................... [ ] Lo The applicant shall provide a short summary of his track record as a developer (examples of projects in other communities: handouts, slide presentation, etc.) ................................................... [ ] [3] SITE PLAN REQUIREMENTS Prints of the site plan shall contain the following information all on one 24" x 36" shec: (submit twenty-two (22) folded prints and three (3) 8½" x 11" reductions .................................... [ ] SITE PLAN ~CUST SHOW: 10. I1. 12. 13. 14. 15. Property dimensions of the site and approximate distance to nearest cross street; ................................................. [~ Ail existing or proposed buildings on the property, existing structures, fire lane and access aasements adjacent to the property, and access points on and adjacent to the property; .......... ~ Setbacks and building lines; All existing private and public streets including street widths, median openings, and left-turn lanes; ................................. Proposed areas of dedication, if necessary, including streets, alleys or easements; .................................................. [ ] Points of ingress and egress to the property including design and spacing of driveways; ................................................ [~ Parking area includ~ng number and layout of spaces, aisle width, garbage pick-up location, fire lanes, and types of surface of fire lanes; ........................................................... [ ] Screening walls and location, type of screening wall, either living or masonry ..................................................... Indicate all area to be landscaped, type of landscaping, and total square footage of landscaped areas; do not use "tree stamps" .......... [>~ Ail existin~ services, fire hydrants, water mains, and sewer mains within the tract and immediately adjacent to it with pipe size and location indicated .................................................... [ ] All proposed water and sanitary sewer pive lines with sizes indicated and valves, fire hydrants, manholes, and other appurtenances or structures shown; .................................... [. ] All propose! or existing water and sewer connections, meter loca- tions, size of meters, with meter and/or detector check valve vaults indicated; ..................................................... [ ] Finished floor elevation of proposed or existing structures on the site referenced to sea level datum; ................................... [ ] Existing and proposed contours of the tract in intervals of one foot or less, referenced to sea level datum; ......................... [~ Proposed or existing on and off-site inlets; culverts or other drainage structures ................................................... [4]