Villages C P1-LR 931005
GEO- CONB~Z, TING ENGINEERS IN= TECHNIQUE ironmenta[ Assessments ~ Soits& Fou~ations Construction Nate~ia[s Testing "ExceLlence by Ex~ience" C~rcia[ & l~ustrJa[ lns~ctJon PO Box 92548 * South[ake, Texas 76092 · (817) ~29-0281 FIELD COMPACTION REPORT PROJECT: Villages of Coppell IV-B LOCATION: Coppell JOB #: 93-959 DATE: 10-05-93 DAY: Tuesday TIME: 9:00am CLIENT: Grand Homes, Inc CONTRACTOR: Boykin Construction WATER DRY PER- TEST PROCTOR CONT. DEN CENT NO. LOCATION AND LIFT NUMBER (%) (PCF) COMP 1. 818 Cheshire FG 1 21.3 100.4 97.7 REMARKS: All tests passed. Minimum Compaction Required: 95% Minimum of 4 tests per trip. FG = Final Grade PROCTORS: 1. Lime Treated Brown & Tan Clay 102.7 PCF @ 19.3% MOISTURE Jeff Holden Technician