Verizon-LR 990310CONCRETE COMPRESSIVE STRENGTH TEST 8901 Carpanter l~y., Suite #100 Dalla% T~*'~n~ 75247 Date of Service: 01/11/1999 Report No.: 9901730 Report Date 03/10/1999 Client No.: 08~.025 Project No.: 43-2333-98 Client: The Beck Group Project: GTE Shared Services Attn: Gillett Berger Coppell Road & Corporate Drive 1700 Pacific Ave., Suite 3800 Dallas TX 75201-4619 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA conxRAc'roR: BECK CONCgETg Ct,ASS: 8208 CONCggrg SUPI'U~: TXI ~,LXCg~yavr DATE: 01/11/1999 BATCH TaYto: 3:46am Pt,At~: 41 xn~SAM~LED: 4:05am BY: Mike Odom SPECIFICATION REQUIREMENTS WF..kTI~RCOt~mrrio~: Fair S~GT~.. 5000 psi @ 28 Days TEM~ERA~Jm~ (~. AiR 42 F concnm~: 55 v s~-~: 6.0" Max TRUCKNO: 470 TICY,~r NO: 1211055 Am: N/A Am conTEt, rr ¢,~): N/A u~rr w~i~;trr (~.: N/A TF.~T METIIOD: ASTM C- 143 Pt. ACEM~t~rr LO~ATION: Level IV, building slab 1-:$.7 & A-D ASTM C-172 ASTM C-39 SAMPLE LOCATION: A.5 @ 1.5 REPORT OF TESTS Accvmnaxrv YARDS: 510 CYLINDER MEASURED MAXIblUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (laches) TESTED (days) (lbs. force) (psi) TYPE 1 1 6.00 0111411999 3 105870 3740 1 2 6.00 01 / 18/1999 7 136780 4840 1 3 6.00 01/18/1999 7 142670 5050 Average 4950 I 4 6.00 02/08/1999 28 212870 7530 1 5 6.00 02/08/1999 28 204390 7230 Average 7380 I 6 6.00 03/08/1999 56 225410 7970 This report is exclusively for thc use of the client indicated above and shall not be reproduced except in full without the wrinen approval of HBC Engineering, Inc. 0iLL Page 1 of 6 CONCRETE COMPRESSIVE STRENGTH TEST 8901 Carpenter Frwy., Suite #100 D~llas, Texas 75247 Date of Service: 01111/1999 Report No.: 9901730 Report Date 03/10/1999 Client No.: 08644025 Project No.: 43-2333-98 Client: The Beck Group Project: GTE Shared Services Attn: Oillett Berger Coppell Road & Corporate Drive 1700 Pacific Ave., Suite 3800 Dallas TX 75201-4619 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: BECK CONCaETE CLASS: 8208 CONCaX'r~ SUPS'LIng: TXI PLAC~.:M~AVr DATE: 01111/1999 BATCH TM: 5:10am PLANT: 41 TIME SAMPLED: 5:50tim BY: Mike Odom SPECIFICATION REQUIREMENTS WEATHER CObrDrrxoNS: Fair s'ra~(;'m: 5000 psi @ 28 Days TEMPERATURE (F). AIR 38 F CONCRETE: 55 g SLUM~: 6.0" Max TRVCK NO: 450 TICg~r NO: 1211104 Am: N/A Am cobrr~N'r (,~): N/A unrr w~l(~trr (p~.-. N/A ~ M~M~M~M~M~M~M~M~M~M~mOD: ASTM C- 143 PLACEMEtCr LOCATION: See page I ASTM C-172 ASTM C-39 SAMPLE LOCATION: B @ 2 REPORT OF TESTS AC TIv VA]RI)S: 510 CYLINDER MF..ASURED lkqA. XlMUM COMPRESSI'~,q~ MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (11~ force) (psi) TYPE 2 I 5.75 01/14/1999 3 113820 4030 2 2 5.75 01/18/1999 7 141660 5010 2 3 5.75 01/18/1999 7 143870 5090 Average 5050 2 4 5.75 02/08/1999 28 226520 8010 2 5 5.75 02/08/1999 28 236900 8380 Average 8200 2 6 5.75 03/08/1999 56 250870 8870 This rep~ is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering. Inc. 0iLL Page 2 of 6 CONCRETE COMPRESSIVE STRENGTH TES3' 8901 Carpenter Frwy. Suite #100 D;dlss, Texas 75247 Date of Service: 01/11/1999 Report No.: 9901730 Report Date 03/10/1999 Client No.: 08644025 Project No.: 43-2333-98 Client: The Beck Group Project: GTE Shared Services Attn: Gillett Berger Coppell Road & Corporate Drive 1700 Pacific Ave., Suite 3800 Dallas TX 75201-4619 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA cot~rrRAcroa: BECK CONC~ CLASS: 8208 CONCRetE SUPPLIER: TXI P~nC~V~rr DATE: 01/11/1999 BATCH XnS_~: 6:17am P~,~rr: 41 T~ SAMPt~D: 6:50am BY: Mike Odom SPECXFICATION REQUIREMENTS WEATHER CONDITIONS: Fail' STm~N~'m: 5000 psi @ 28 Days TEM~Z~T~RE (~. Am 40 F CONCRETE: 55 F SLUMP: 6.0" Max TgUC~CNO: 458 ~cr~'rNo: 1211166 nxm N/A AIR cot~TEtvr (,~): N/A t~iT WEIGHT (peO.'. N/A TF_~T tvm'rtioD: ASTM C- 143 PLACEMEtVr LOCATION: See page I ASTM C- 172 ASTM C-39 SAMPLE LOCATION: C @ 3 REPORT OF TESTS ACCUMULA VE YARDS: 510 CYLINDER MEASURED MAXIMUM COM~IVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (Ib~ force) (psi) TYPE 3 1 5.50 01/14/1999 3 126070 4460 3 2 5.50 01/18/1999 7 192590 6810 3 3 5.50 01118/1999 7 204100 7220 Average 7020 3 4 5.50 02/0811999 28 234570 8300 3 5 5.50 02/08/1999 28 220780 7810 Average 8060 3 6 5.50 03/08/1999 56 248030 8770 This repo~ is exclusively for the usc of thc client indicated above a~d shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 0ILL Page 3 of 6 CONCRETE COMPRESSIVE STRENGTH TESI' ' 8901 Carpenter- Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 01/11/1999 Report No.: 9901730 Report Date 03/10/1999 Client No.: 08644025 Project No.: 43-2333-98 Client: The Beck Group Project: GTE Shared Services Attn: Gillett Berger Coppell Road & Corporate Drive 1700 Pacific Ave., Suite 3800 Dallas TX 75201-4619 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTaAcroa: BECK coNc~ CLASS: 8208 CONCRETE SUPPLIER: TXI PLAC~IE~'r DATE: 01/11/1999 BATCH T~: 7:lSam P~: 41 T~Z SAILED: 8:~am BY: Mike Odom SPEC~I~TION ~UI~ ~R co~mo~: Fair ~G~: 5~psi~ 28Days ~~(~-Am 41 V CO~C~: 55 F SL~: 6.0" M~ ~uC~O: 453 x~C~ ~O: 1211294 AIR: N/A Am co~ (%): N/A UN~ WEIG~ (~: N/A ~ M~IOD: AS~ C-143 P~c~ ~CATION: ~ page 1 AS~ C-172 AS~ C-39 SAMPLE ~CA~ON: C ~ 3.3 PORT OF T TS 510 CYL~ER ~U~D ~~! COheSiVE ~D SL~P DA~ AGE LOAD S~G~ F~~ S~ NO. (~) ~ (da~) ~ force) (~i) ~E 4 I 5.25 01/1~ 1999 3 103740 3670 4 ~ 5.25 01/1~1999 7 1&73~0 ~I0 4 3 5.25 01/18/1999 7 142720 5050 Avenge 5130 4 4 5.25 0~8/1999 28 223550 7910 4 5 5.25 0~08/1999 28 2417~ 8550 Average 8~0 4 6 5.25 03/08/1999 56 254330 8990 This report is exclusively for thc use of thc client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 0iLL Page 4 of 6 CONCRETE COMPRESSIVE STRENGTH TES 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 0111111999 Report No.: 9901730 Report Date 03/10/1999 Client No.: 08644025 Project No.: 43-2333-98 Client: The Beck Group Project: GTE Shared Services Attn: Gillett Berger Coppell Road & Corporate Drive 1700 Pacific Ave., Suite 3800 Dallas TX 75201-4619 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA COntrACTOR: BECK CONCRETE CLASS: 8208 CONCRETE SUPPLIER: TXI PLAcgMgivr DATE: 01/11/1999 BATCH Tnvm: 8:41am PLANt: 41 TIME SAMPLED: 9:25am BY: Mike Odom SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Partly cloudy STRgNGTH: 5000 psi @ 28 Days TEMPEga~Jm~ ~. Am 50 F CONCRETE: 55 F SLUMP: 6.0" Max TRUCKNO: 461 TICKETNO: 1211437 AIR: N/A Am CO~rr (,~): N/A u~wr WgmUT (pc0: N/A TF.,~I~ METIIOD: ASTlVI C- 143 PLACEME~rr LOCATION: See page 1 ASTM C- 172 ASTM C-39 SAMPLE LOCATION: C-4 REPORT OF TESTS Acc a Tr YARD : 510 C ER ,, -,,sURED com, REssr MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inch.) TESTED (days) (lbs. for~) (psi) TYPE 5 1 5.50 01/14/1999 3 106020 3750 5 2 5.50 01/18/1999 7 168550 5960 5 3 5.50 01/18/1999 7 154600 5470 Average 5720 5 4 5.50 02/08/1999 28 217620 7700 5 5 5.50 02/08/1999 28 223890 7920 Average 7810 5 6 5.50 03/08/1999 56 241350 8540 This report is exclusively for the use of thc client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 0ILL Page 5 of 6 l~epo.rt No.: 9901730 ,,~,,,~,~ Note: Ail samples and slumps were taken at hopper. Ten gallons of water was added for this set. Technician: Mike Odom Started: 3:00am Finished: lO:OOam ~ Eng~ Report Distribution: (1) The Beck Group (1) The Beck Group (1) Gromatzky Dupree & Assoc. (I) Daican, Inc. Eugene Harbour (i) Brockette Davis Drake, Inc. Vice President (i) The Beck Group This report is exclusively for the use of ~he client indicated above nnd shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 0ILL Page 6 of 6 CONCRETE COMPRESSIVE STRENGTH TEST 8901 Carpente~ Frwy., Suite #100 ~ Texas 75247 Date of Service: 03/01/1999 Report No.: 9906359 Report Date 03/10/1999 Client No.: 08644025 Project No.: 43-2333-98 Client: The Beck Group Project: GTE Shared Services Atto: Gillett Berger Coppell Road & Corporate Drive 1700 Pacific Ave., Suite 3800 Dallas TX 75201-4619 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA coto'~crom BECK CONCn~"r~ ct,~s: 8208 CONCRETE SUPPLIER: TXI PLACEM~tr DATE: 03101/1999 BATCH TIME: 12:229m PLA~r: 31 TIME SAMPLED: h20pm BY: Mike Odom SPECi~CATION REQUIREblEN~ WEATHER CoNDmONS: Fair s'rRE~TH: 5000 psi @ 28 Days TE~v~-~TIn~ (v). Am 76 F CONCRZ'ng: 76 F SLUMP: 6.0" Max T~UC~NO: 559 TICKET NO: 1253231 AiR: N/A Am cOWrENT (~): N/A uNrr wEK;irr (po'):. N/A TEST METHOD: ASTIV~ C- 143 ~L~C~n~:~T LOCATION: (20) Level Ill-IV columns Area C ASTM C-172 ASTM C-39 SAblPLE LOCATION: E @ 14 REPORT OF TESTS YARDS: de4 CYLINDER MEASURED MAX~IUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (incl~s) TESTED (days) (11~ force) (psi) TYPE I 1 5.75 03/08/1999 7 133050 4710 1 2 5.75 03/08/1999 7 137950 4880 Average 4800 I 3 5.75 03/29/1999 28 I 4 5.75 03/29/1999 28 1 5 5.75 04/26/1999 56 Technician time: See Report 89906360 ~ Ten (10) gallons of water added. Technician: Mike Odom Started: Finished: H~ Report Distribution: (I) The Bo:k Group (!) The Beck Group (I) Gromatzky Duprec & Assoc. (1) Dalcan, Inc. Eugene Harbour (I) Brockette Davis Drake, Inc. Vice President (1) The Beck Group This report is exclusively for the use of the client indicated above and shall no~ be reproduced except in full without the written approval of HBC Engineering, Inc. 0ILL Page 1 of I CONCRETE COMPRESSIVE STRENGTH TEST' 8991 Cm'pea~r Fray., Suit~ #100 D~las, Teums 7S247 Date of Service: 0310111999 Report No.: 9906360 Report Date 0311011999 Client No.: 08644025 Project No.: 43-2333-98 Client: The Beck Group Project: GTE Shared Services Arm: Gillett Berger Coppell Road & Corporate Drive 1700 Pacific Ave., Suite 3800 Dallas TX 75201-4619 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA coNTn.~croR: BECK CONCRETE CLASS: 9506 CONCRE'rESU~LmR: TXI ~'LAC~DATE: 03/01/1999 SATCHTE~E: l:21pm PLANT: 41 xnm~ SAMPLED: N/A SY: Mike Odom SPECIFICATION REQUIREMENTS WEATHER CONDmONS: Fair STRF~(;TH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 76 g CONCRETE: 78 ~ SLUMP: 6.0" Max TRUCKNO: 804 Ticg_~-'r NO: 1253330 AIR: N/A Am COt~'Eirr (~S): 2.8 Ut, OT WEXGtrr (t~ N/A TEST METIIm): ASTM C- 143 ~'LAC~ LOCATION: Dock ramp Area A Level I ASTM C-172 ASTM C-39 SAMPLE LOCATION: 10' S of building tie-in REPORT OF TESTS ACCUMULATIVE YARDS: 50 cYLmO .R COMPR nr MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE S~F NO. (inches) TESTED (days) (lbs. force) (psi) TYPE I 1 6.00 03/08/1999 7 95080 3360 I 2 6.00 03/08/1999 7 96030 3400 Average 3380 I 3 6.00 03/29/1999 28 I 4 6.00 03/29/1999 28 I 5 6.00 04/26/1999 56 Ten (10) gallons of water added. Technician: Mike Odom Started: l:00pm Finished: 4:00pm ~g, Inc. Report Distribution: (I) The Beck Group (1) The Beck Group (I) Gromatzky Dupree & Assoc. (!) Dalcan, inc. Eugene Harbour (1) Brockette Davis Drake, Inc. Vice President (1) The Beck Group This report is exclusively for the usc of the client indicated above and shall not be reproduced except in full without thc wriucn approval of HBC Engineering, Inc. 0iLL Page 1 of I