Valley Ranch SS-CS 940126 Coppell. Texas 75019
he City With A Beautiful Future 214-462-0022
January 26, 1994
Mark Roberts
Brockett, Davis, and Drake Inc.
3535 Travis Suite 100
Dallas, Texas 75204
RE: Landscape Review Comments for Valley Ranch Self Storage Addition
Dear Mr. Roberts:
The City of Coppell has received the referenced plans and has the following comments
to offer:
~ 1. Show and construct brick pavers and handicapped ramps as per Coppell
Streetscape Plan.
./ 2. Show location of wall on plan view. Will wall also be on the south side of the
development?
.~ 3. Show irrigation plan on landscape plan.
Perimeter landscape areas shall contain at least one (1) tree for each fifty (50)
linear feet or fraction thereof of perimeter area as per Section 34-1-8(B)3;
Coppell Zoning Ordinance.
Show title sheet on next set of landscape plans.
.~-~ 6. Schedule of approved plant materials (from Streetscape Plan) needs to be
added to landscape plans.
/ 7. Ten (10) percent of gross parking area needs to be devoted to living
landscaping as per Section 34-1-8(B)3; Coppell Zoning Ordinance. However;
if gross parking area is 35,000 sf or less, planter islands are not required.
There are various other minor comments throughout these plans. Once these
comments have been addressed, the revised set of plans should be resubmitted to the
City for review. If you should have any questions concerning these comments, please
feel free to contact me at 393-1016.
Sincerely,
Atul Patel, E.I.T
Graduate Engineer
___ Coppell, Texas 75019
The City With A Beautiful Future 214-462-0022
January 26,1994
Mark Roberts
Brockett, Davis, and Drake Inc.
3535 Travis Suite 100
Dallas, Texas 75204
RE: Construction Review Comments for Valley Ranch Self Storage Addition
Dear Mr. Roberts:
The City of Coppell has received the referenced plans and has the following comments
to offer:
Locate vaults and services with meter and backfiow preventers outside paving
and sidewalks and install in easement or right-of-way.
2. Remove existing 2" water line once new 12" water line is constructed.
Reconnect existing 2" water line to new 12" water line at east side of property
line. Get permission from Mr. Robinson to do work.
3. Trucks cannot make right turn into and out of sight safely. Need to consider
maximum right turn radius of 25' to accommodate truck and trailer turning
movements.
~ "~., 4. Consider painting cast iron bollards reflective yellow for each of internal fire
hydrants.
Setback a minimum of three (3} feet back off of the building for repair of fire
hydrants.
· 6. Show erosion control on construction plans.
7. Show turning radii for C3 and C9 on construction plans.
There are various other minor comments throughout these plans. Once these
comments have been addressed, the revised set of plans should be resubmitted to the
City for review. If you should have any questions concerning these comments, please
feel free to contact me at 393-1016.
Sincerely,
Atul P~atel, E.~"
Graduate Engineer