Villages C P2-CS 851031GINN, INC. CONSULTING ENGINEERS
October 31, 1985 ~;~
Mr. Larry Broach ~
Nathan D. Maier ~~
Three Northpark ~
8800 N. Central Expressway, #300
Dallas, Texas 75231
Re:Villages of Coppell - Phase 2
Coppell, Texas
Dear Sir:
We have reviewed the above referenced project for conformance
to the City of Coppell Zoning Ordinance and Subdivision
Ordinance. Prior to placing on any agenda for approval, the
following items need to be addressed.
1. Chalfont Place cul-de-sac is greater than 600 feet in
length. Subdivision Ordinance requires that cul-de-sac
shall be no longer than 600 feet. Please address.
2. Provide drainage criteria used in storm sewer design.
3. Storm sewer, "Line A," needs an easement across Lot 1
shown and indicated on plat.
4. Will the 8" sanitary sewer on 0.30% provide a minimum
2.0 f.p.s, velocity? Please address.
5. Provide details of headwalls.
6. Provide details of backfill, inlets, manholes, etc.
7. Provide cross section of street and alleys.
8. Detail sheets should be made a part of plans.
9. Please address miscellaneous comments shown on plans.
In order to be place on the November 21, 1985, P & Z agenda
for final plat approval, the above items need to be addressed
prior to November 13, 1985. If you have any questions,
please contact us.
Sincerely,
Gabe Favre
cc: Vivyon Bowman
Steve Goram
1613qPrcstonRoad' Suitel06, Dallas. Texas75248, Phone214..386-6611