Loading...
Verizon-SP 980722VICINITY MAP iORTH DENTO~ ROUND GROVE RD FM. 3040 TO 121 BYPASS SITE CORPORATE SANDY LAKE RD. TO DFW AIRPORT ~C.-)/'-.) II'..1(_~ I"'IA.Fb  GTE LOGO AND LETTERING STYLE BY TENANT DOUBLE SIDED SIGN SHARED SERVICES (~ MONUMENT SION SCALE: .3/4"=1'-0" 60 S.F. PERMITTED 30 FT. LIGHT POLE BOLT COVER PLATES FIN. TO MATCH POLES GROUT BENEATH ~- BASEPLATE / CONC. BASE GRADE OR PAVING REF. SITE/CIVIL ANCHOR BOLT - SIZED PER POLE MANUFACTURER 8 #6 BARS #3 ROUND TIES ~ 12" O,C. CONDUIT 30" BELOW GRADE (MIN.) REF, MEP NOTE: ALL ISOLATION JOINTS @ PAVEMENT TO BE SEALED : 1/2= 1'-0" ORLANDO POST-TOP MOUNTS Eujoy the sleek styling of the ORLANDO with Post-Top Mounting. With Spider Mount, tile luminaire housing is supported by two twin-tube arms attached to a pole top adapter. The Yoke Mount is formed by two square arms attached to a pole top adapter. The fitters for both SM and YM bolt to a plate on the pole top with concealed hardware. All optional adapter allows mounting to a 2-3/8" OD pole top tenon. POLE MOUNT A popular mounting style is Pole Mount where single, twin. triple and quad configurations are possible. Side mount luminaires include an extruded aluminmn arm with four bolts for rigid attachment to the pole. Staudards length is 6" for small and 10" for the large housing. When fixtures are mounted at 90? the small housing requires a 10" arm a 12.5" is needed for the large. QUAD CONFIGURATIONS The perfect solution for shopping malls, parks, parking lots or any location requiring a large lighted area. The quad configuration allows four round or square ORLANDO fixtures to be mounted directly to a pole at 90° angles. MGM Grand Hotel, Las Vegas, NV. 'DNI 'DNI. I,HDI~I DNI~FI~IVd$ s DS210 Round Tapered ~--POLE TOP CAP SECURED WITH 5 SET SCREWS ~ POLE SHAFT POLE MAY BE DRill Fn TO ACCEPT SIDE MOUNTED FIXTURE IF REQUIRED. I / DETAIL -- ]'ENO LENG'TH ROUND PLATE EBURRED) - (in) P2 2.575 2.0' SCHED 80 P4 4.000 5.5" SCHED 40 6 PL 2.400 POLE TOP N.A. TENON DETAIL (STANDARD) BOLT CIRCLE. F BOLT COVER CASTING WITH FASTENERS THICKNESS ~ SQiARE t /--- BOLT HOLES OR SLOTS POLE BASE DETAIL 24 MOUNTING HEIGHT ~CED HANDHOLE W/COVER AND GROUNDING 4 - ANCHOR BOLTS WITH THREADED END GALVANIZED 12' MIN. EACH BOLT FURNISHED WITH 2 HEX NUTS AND 2 FLATWASH ERS. DS210 POLE DETAIL Nominal haft~ e Base Anchor Bolts w/1.3 Gust w/1.3 Gusl w/1.3 Gust Mounting o~,/ Base Top Wall S~c~. BoltCircle Max. Max. Max. Max. Max Max. Height Designati O.D. O.D. Thk. ./Wreight Dia. -+ Square Thk. Dia. x Lngth. x Hk. EPA Weight EPA Weight EPA Weighl ([I) Number/ (in) (in) (ga),,- (lbs) (in) (in) (in) (in) (in) (fl~) (lbs) (fl~) (lbs) (ft~) (lbs) **590A20~-P2 5.9 3.1 ,,'~1 140 9.0 .5 10.00 0.88 1.00 x 36 x 4 19.3 482 15.1 377 12.2 305 20 650A,?.,~-P2 6.5 3r7" 11 160 9.5 .5 10.50 0.88 1.00 x 36 x 4 24.2 605 19.3 482 15.6 390 **590A~50-PL 5.9 /2.4 11 155 9.0 .5 10.00 0.88 1.00 x 36 x 4 12.5 312 9.9 247 8.0 200 25 700/~50-P2 729' 3.5 11 200 10.0 .5 10.88 0.88 1.00x36x4 20.3 507 16.2 7001~250-P2('7.0 3.5 7 280 10.0 .5 10.88 1.00 1.00 x 36 x 4 28.5 713 22.5 405563 13.118.2455327 660,~,300-PL / 6.6 2.4 11 200 9.5 .5 10.50 0.88 1.00 x 36 x 4 11.7 292 9.3 232 7.5 187 30 800,~,300-P,~ 8.0 3.8 11 265 11.0 .5 11.50 0.88 1.00 x 36 x 4 18.9 473 14.9 373 12.0 300 800 ~,300-1~2 8.0 3.8 7 380 11.0 .5 11.50 1.25 1.25 x 42 x 6 17.5 439 21.6 542 17.5 439 ~ 730A~3~-~ 7.3 2.4 11 250 10.5 .5 11.25 0.88 1.00 x 36 x 4 11.2 280 8.9 222 7.1 177 ~ 850A350-P2 8.5 3.6 11 315 11.5 .5. 12.00 1.00 1.00x36x4 18.9 472 15.1 377 12.2 305 950A350-P2 9.5 4.6 11 370 ,13.0 .5 13.00 1.00 1.00 x 36 x 4 23.2 580 18.2 455 14.5 363 782A389-PL 7.8 2.4 11 285 11.0 .5 11.50 1.00 1.00 x 36 x 4 10.7 267 8.5 212 6.6 165 39 900A389-P2 9.0 3.6 11 355 12.5 .5 12.38 1.00 1.00 x 36 x 4 17.2 430 13.5 338 10.8 270 900E389-P2 9.0 3.6 7 515 12.5 .5 12.38 1.25 1.25x42x6 26.1 654 20.6 517 16.7 419 45 TOOA450-P2 10.0 3.7 11 450 13.5 .5 14.00 1.00 1.00x36x4 17.4 435 13.5 338 t0.6 265 T00E450-P2 10.0 3.7 7 650 13.5 .5 14.00 1.25 1.25x42x6 25.5 639 20.2 505 16.3 409 E00E450-P4 11.0 4.7 7 780 15.0 .5 16.50 1.50 1.25x42x 6 35.7 893 28.0 700 22.3 558 T00A500-P2 10.0 3.0 11 475 13.5 .5 14.00 1.00 1.00 x 38 x 4 13.2 330 10.6 265 8.3 208 T00E500-P2 10.0 3.0 7 680 13.5 .5 14.00 1.25 1.25x42x6 20.5 512 16.5 412 13.6 340 50 E00E500-P4 11.0 4.0 7 812 15.0 .5 16.50 1.50 1.25x42x6 29.9 748 23.5 588 18.6 465 H00E500-P4 13.0 6.0 7 1020 17.0 N/A 18.00 1.50 1.50x54x6 50.4 1260 39.7 992 31.4 785 H00J500-P4 13.0 6.0 3 1335 17.5 ' N/A 18.50 1.75 i 1.75 x 84 x 6 69.2 1730 55.0 1375 44.2 1105 E00E550-P4 11.0 3.5 7& 11 890 15.0 .5 16.50 1.50 1.25x42x6 21.6 540 17.7 442 14.7 367 55 W00E550-P4 12.0 4.5 7&11 975 16.0 N/A 17.00 1.50 1.50x54x6 32.2 805 25.9 805 21.1 527 W504550-P4 12.5 5.2 5&7 1225 16.5 N/A 17.50 1.50 1.50x54x6 43.8 1095 35.0 875 28.6 715 W00E600-P4 12.0 4.0 7& 7 1060 16.0 N/A' 17.00 1.50 -l.50x54x6 25.9 547 20.7 517 16.8 420 60 H00E600-P4 13.0 4.8 7&11 1075 17.0 N/A 18.00 1.50 1.50x54x6 30.1 752 24.5 612 20.2 505 W504600-P4 12.5 4.5 5& 7 1275 16.5 N/A 17.50 1.50 1.50~(54x6 34.0 850 27.6 690 22.6 565 65 H00E650-P4 13.0 4.3 7&7 1200 17.0 N/A 18.00 1.50 1.50x54x6 27.3 682 22.0 550 17.9 447 H004650-P4 13.0 4.3 5&7 1400 17.0 N/A 18.00 1.50 1.50x54x6 30.8 770 24.8 620 20.4 510 70 H00E700-P4 13.0 3.6 7&7 1270 17.0 N/A 18.00 1.50 1.50x54x6 20.6 515 16.7 417 13.7 342 H004700-P4 13.0 3.6 5 & 7 1440 17.0 N/A 18.00 1.50 1.50 x 54 x 6 23.6 590 19.2 480 15.8 395 DS210 NOTES: 1. **3" x 5" nominal handhole - all others 4" x 6.5" nominal. 2. Structure weight is a nominal value which includes the pole shaft and base plate only. 3. Designs showing two shaft gauges indicates structure is provided as a two-piece, field assembled, unit. Heavier gauge is the bottom section. 4. Maximum weight and EPA values are based on top mounted luminaires and/or brackets having a centroid 2'-6" above the nominal mounting height. 23 SL5 I~ K Jmliilhtin~ See page 13 for Ordering Infor,, ..~don Specifications Head: One piece cast alurnir~um, !'~,' wall lhickness, atlached to shaft by four bolls concealed wilhiu the head, fully gaskeled. Shaft: One piece extruded aluminum with internal tracks for base attachment Cast aluminum top cap internally secured and fully gasketed. Base: One piece cast aluminum secured to shaft by four concealed stainless steel bolts. Reflector and Socket: Formed specular Alzak,~:' reflector panel secured to a harness which holds a porcelain medium base 4KV socket (H.I D. and incan- descent), GX24q-3 socket (32W fluorescent), or GX23 socket ( 13W fluorescent) Lens: Clear flat F,," thick polycarbonate retained by three captive pressure limiling allen head shoulder screws, fully gasketed. Ballast: HPF 20'~F. starling (H.I.D.), NPF 32'~F. starliu9 (13W fluorescent), 0°F starting (32W fluorescent), mounled and pre-wired on a single harness s~Jspended within Ihe shaft Wire leads supplied Io base Anchor Bolts: Four F, Fx10'+2' zk i(; plated L hooks complete with leveling nuts, washers, couplings, rigid pressed board templale and black slaintess sleel bolts, Finish: Super [GIC thermosel polyester powder coat paint over a chromate conversion coating Available colors are Black, Dark Bronze. Lieht Gray o~ White Certification: UL listed to U.S and Canadian safety standards. Fixture man- ulacturer shall be registered to Isa 9001 See page 12 for installation details 8" [amp Modes (coated lamps recommended) A B C D E F G / overall heighl available. Consult 9' rw'--] Klm representative. Bolt ~ Base Plan 50W. HPS. coated ED17 meal base, 3800 initial lumens 70W I ~PS. coated ED 17 med base, 5985 inilial lumens 50W. MH, coated ED17 meal base, 3400 initial vertical hJmens 70W. MFt. coated ED17 med. base, 5400 initial vertical Inmens 13W. Compacl Fluorescenl, GX23 base, 900 initial lumens 32W. Compact Fluorescent, GX24q-3 base, 2400 initial lumens 100W, Incandescent, A19 IF reed base. 1750 initial lumens Initial Horizontal Footcandles for 42" Fixture (33' Light Cenler) Typical Half 6 3' ,0;-,-"" 6' 9' 12' 15' 18' ~ 21' 1 7 20 56 35 7.5 12 42 38 35 70 20 18 15 25 J 08 07 07 12 03 02 03 05 03 01 (CI ( · 0 'D 3 2 I 0 I 2 3 3 2 I Il I 2 3 APPLICATIONS · Walkways · Entrances · Community centers · School campuses · Landscape areas · Hotels · Coudyards · Malls CONSTRUCTION FEATURES HOUSING · [xtruded aluminum · Flush hardware · Single screw access for top relamping DPTICAL ASSEMBLY · Dual highly specular anodized · Tube optics, optional · Symmetrical type V pattern BALLAST ASSEMBLY · High power factor, starting rated to -2§°F · Mercury Vapor (DX) and Metal Halide (M): constant wattage autotransfarmer or high reactance type · High Pressure Sodium ($): constant wattage autotransformer, high reactance, or reactor type with electronic starter AMPHOLDER · Enclosed medium base porcelain socket · Nickel plated center contact · Reinforced lamp grip screw shell FINISH · Bal~ed an polyester · Available in I§ standard colors · Consult factory for custom finishes MOUNTING METHODS ANCHOR BASE · Concealed galvanized base plate · 4" Bolt circle · Square pattern · .5"x I0" anchor bolts OPTIONAL TUBE OPTICS SpeciN with suffix "T". L, UMINAIRE ORDERING GUIDE MODEl. I.MP TYPE/ OPTICAl, VOI.T'AC-,E WATT.~ SYSTEM MDIII: Squor~ DXlI1B ~ D: Dual reflector For DX Il H 14OlV: Round (standard) 120 ~ MTO ~,.,'-. 208 MIDD T: Tube optico240 277 S35 S5[1 For S35 6 INC "S?D ? ~ 120 SIO§ INCI5D COl,O~ DBZ Dark Bronze BGE Beige RRN Rocket Red SbB Bid ~ Versatility - Ground Mounting: "~/i'~P-.. '*~'~t~*' The AFL functions beautifully for lighting architectural facades and walls, high level landscaping, sculplure, signage and flags. Several ground-mounting options offer versatility and economy by providing multiple-fixture mounts with the added permanence and strength of a stanchion. For areas where vandalism is a concern, we recommend the Heavy Duty Swivel as added security against tampering. Additional vandal resistance can be achieved with the polycarbonate lens option. For locations where it is necessary to shield or control the light source, available options are the fully-adjustable barn doors and the fixed hood, which can be mounted along the top or the bottom of the lens. Wall Mounting: Because it is such a clean and simple form, the AFL can be wall mounted as a complementary addition to architecture. As a wall mounted luminaire, the AFL becomes a versatile exterior and inte- rior lighting tool. When mounted on building exterior walls, areas around the structure can be economically illuminated, saving the cost of poles. As an interior lighting instrument, the AFL provides an ideal lighting solution for today's atriums and high ceilings. The AFL Barn Door system should be considered ideal for precision glare control in interior applications. Where walls or columns are not available, the AFL can also be ceiling mounted. Klm Lighting ~t.~ ~ For high-wattage full size Kim Product Struc- '5=' Architectural Floodlights, contact Fixtures with Standard Swivel your local Klm representative. See pages 12 through 15 for ordering information BD Barn Doors WM Wall or Ceiling Mount J27N Surface Mounl dunction Box JB1 ^rchitectural Junction Box SM18 Stanchion Mount '?r:,; 7- 7 ~ 7'7 7 F Z.,,.../. / .,/ /,, 7o? f~ .... / /'/I Ih~,~rr ~ ~',~(',, ',, ',, '\/ ~, ', I. ,. ( ,/ ,/ AFL-LS Polycarbonate Lens Shield AFL 1,2, 3, 4 with Standard Swivel. PT PT2 Post Post Mount Mount Single Double WM1 Wall Mount SPM Side Pole Mount TM2 Twin Mount SM2 M2B Twin Mount Tenon SPT Side Pole Mount Tenon Stanchion Mount Tenon FH Fixed Hood Pole with 2' pipe size tenon by Klm or others. 4 Kim Lighting Application Gui,"'e - AFL1 Horizontal Spot General Guidelines. The AFL1 horizontal beam pattern is designed to illuminate surfaces that are more horizon- tal than vertical or longer than wide.The AFL1 is designed for broad illumination with the fixture relatively close to the lighted sur- face. Recommended distance from the lighted surface is 6' to 20' depending on lamp and wattage. Optimum aiming angle is 37.5°. See pages 18 through 22 for photometric reports. Facades-one to two stories. ~AFL2 ~- ~ AFL1 AFL1 in combination with AFL2 for facades of varying height. ~ II Ill-itl I ,,. Signs-horizontal.,/ Parking-single rows along sides of building, Atriums-narrow. Ceilings- narrow. Fixtures mounted at grade oron trunk above eye level. Walls. Shipping Docks. Courtyards- narrow. Hedge Rows. Fixture Spe_cifications Warning: Fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Certification: U.L. listed (for 120, 208, 240 and 277 Volt only) and C.S.A. certi- fied (for 120 and 347 Volt only) for wet locations. Housing: One piece die cast alu- minum in a cylindrical shape with inte- gral cooling fins over the entire length, and .125" minimum wall thickness. Concealed integral cast slip hinges with stainless steel pins. Door Frame: One piece die cast alu- minum with integral cooling fins,. 125" minimum wall thickness, mates with housing to create a continuous cylindri- cai shape. Concealed integral cast slip hinges allow removal without tools. Stop-arm provided to limit door frame opening. 3A6" thick clear tempered glass lens is sealed to door frame by a one piece molded silicone gasket. One piece molded silicone gasket between housing and door frame, concealed when fixture is dosed. Door frame secures to housing by two stainless steel recessed captive allen-head screws. Four tapped and plugged holes provided for attachment of options. Standard Swivel: Die cast aluminum with internal locking teeth providing 7.50 adjustment intervals. Stainless steel allen-head locking screws, bear- ing flange and 1/2" N.RS, M nipple. Heavy Duty Swivel: Cast aluminum with locking teeth providing 5° adjust- merit intervals. 3/8" stainless steel lock- ing bolt. Two 3/8" stainless steel set point screws secure swivel to any 2" pipe size tenon. (23/8'' O.D. x 31/2'' min. length). Reflector Assemblies: Interchange- able in all four AFL fixture types. Specular Alzak® aluminum optical components mounted to clear an- odized aluminum frame. Reflector as- sembly snaps into fixture housing with spring clips. HPS and MH medium base sockets are porcelain rated 4K~/ Electrical Components: Factory mounted in housing and prewired with leads extending from swivel. U.L. rec- ognized components with high power factor ballasts rated for -20°E starting. Optional photocell internally mounted with sensor on side of housing. Finish: Housing, lens frame and swivel are Super TGIC Thermoset Polyester Powder Coat Paint applied over a chromate conversion coating in Black, Dark Bronze, Light Gray or White colors, Photometrics: Based on Indep- endent Testing Laboratory (ITL) reports, AFL 1, 2, 3, & 4 WITH STANDARD SWIVEL Front ~- Y~" N.S.P.M. Single Fixture E.P,A, 0.7 (45° tilt) 1.0 (Face-on) Weight 24 lbs. maximum Side 127.5° Aiming Range (May be limited by selected mounting option as shown on pages 13-15) F- AFL 1, 2, 3, & 4 WITH HEAVY DUTY SWIVEL Front Single Fixture E.P.A. 0.8 (45° tilt) 1.1 (Face-on) Weight 25 lbs. maximum Slips over 2" p~pe size tenon (2%" O.D x 3Y2" minimum length) Side 145° \ Aiming Range Kim Lighting 11