Loading...
Northlake 635(4)-LR010125 (2) GEOTECHNICAL AND ~ F:=I r-1 U F~ ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell Tach Center II 1322 Crestside Coppell, Texas REPORTED TO: Bob Moore Construction Co. REPORT NO. 79 1110 N. Watson Road REG PROJECT NO. 7044 Arlington, Texas 76011 SAMPLE DATE: 01-25-01 ATTN: Mr. Ed T. McGuire TECHNICIAN: R. Estep CONTRACTOR: Bob Moore Construction Co. Location of Sample Set Number I Location I Quantity Represented 1 Screenwall Piers: 134, 138 and 139. 10/14 Design Information Is°urce °f c°ncrete ITXI Mix Identification 8273 I Specified Strength p.s.i. 3000 Test Results Set Cylinder J I Age@ Total Load J CompressiveI Average No. ID Date Tested Test lbs. Strength p,s.i, Strength p.s.i, 1 3088 02-01-01 7 105190 3720 3088 02-01-01 7 103140 3650 3690 3088 02-22-01 28 144970 5130 3088 02-22-01 28 142460 5040 5090 Cylinder Data Set Cylinder Time of I I Concrete Air I Ticket No. ID Slump Sample Air Temp. Temp. Entrainment Number 3088 4.75 2:00PM 54 57 N/A 2814539 Mail Submitted by: Distribution: (1) Bob Moore Construction Co./ Mr. Ed T. McGuire REED ENGINEERING GROUP, INC. (1) City of Coppell/Mr. LarryDavis (1) City of Coppell/Mr. Lee Stone Original Signed By (1) McHale Consulting Engineering/ Mr. Gary McHale Keith Atkins (1) CMC-Commercial Realty/ KEA/je Mr. Steve Huff (1) AECC, Inc./Mr. Chad Stevens 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019