Loading...
Northlake 635(4)-LR010124 (2) GEOTECHNICAL AND J ENVIRONMI:NTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell Tach Center II 1322 Crestside Coppell, Texas REPORTED TO: Bob Moore Construction Co. REPORT NO. 77 1110 N. Watson Road REG PROJECT NO. 7044 Arlington, Texas 76011 SAMPLE DATE: 01-24-01 ATTN: Mr. Ed T. McGuire TECHNICIAN: B. Woolwine CONTRACTOR: Bob Moore Construction Co. Location of Sample [Set Number I L°cati°nl Panel # 44 J Quantity Represented10/70 Design Information JS°urce °f c°ncrete ITXI Mix Identification 8273 J Specified Strength P's'i' I 3000 Test Results Set Cylinder [ [ Age @ I Total Load J CompressiveI Average No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i. 1 3007 01-31-01 7 94700 3350 3007 01-31-01 7 90630 3210 3280 3007 02-21-01 28 122080 4320 3007 02-21-01 28 123800 4380 4350 Cylinder Data Set I Cylinderj Time of I Concrete Air J Ticket INo. ID Slump Sample Air Temp. Temp. Entrainment Number 3007 5.0 12:15PM 52 59 N/A 2813244 Mail Submitted by: Distribution: (1) Bob Moore Construction Co./ Mr. Ed T. McGuire REED ENGINEERING GROUP, INC. (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone Original Signed By (1) McHale Consulting Engineering/ Mr. Gary McHale Keith Atkins (1) CMC-Commercial Realty/ KEA/je Mr. Steve Huff (1) AECC, Inc./Mr. Chad Stevens 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019