Town Center L4B1-LR011025 (2) x sx .a,
2209 Wisconsin St., Suite ,00 Concrete
Compression Test
Report
(972) 620-8911
Tested For: CONSTRUCTION MANAGEMENT GROUP Our Report No.: 01612-29
ATTN: MR. JEFF MILLER Issue Date: 10/25/2001
5207 MCKINNEY AVENUE, SUITE 12
DALLAS, TX 75205
Fax Number: (214) 521-1279
Project Des¢: COPPELL TOWN CENTER
120 N. DENTON TAPP-- COPPELL, TX
FIELD DA TA
Placement Location: PAVING, 75'S & 80~N FROM THE SW CORNER OF THE MAIN BUILDING
Date Placed: 10/12/01 Plant Number: -4000
11me Placed: 10:10 AM Delivery Ticket No.: 102410
Slump (ASTM C-143): 4.0 Made By:. ALPHA
Air Content: 4.3 (ASTM C-173) Cured Specification: ASTM C-31
Air Temperature: 62
Specimen Temperature: 63
Date Received: 10/13/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: AZMAR, OMAR
Mix Data Submitted By: NELSON BROS.
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: 13/pe: spec: Tested: (Da~sl: Len~lth Width Diameter ScI. In. Load: PSI:
29 LAB C-1231 10/19/01 7 12 N/A 6 28.27 113470 4010
30 LAB 11/9/01 28 12 N/A 6 28.27 0
31 LAB 11/9/01 28 12 N/A 6 28.27 0
32 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 4000
Results to Date: N/A
Note~:
CC: HIS, CITY OF COPPELL, CONSTRUCTION MANAGEMENT GROUP
Respectfully Submitted By: ,~(/ of Alpha Testing, Inc.
Our test reshlts and repom are for the excludve use of the Client (and their designated receplents on file in our office) and shall not be reproduced and/or dislrlbuted except
. with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed, and are not Indicative of the qua#ties of apparently Identical or similar specimens.
ALPHA TESTING, INC.
Concrete
Test
2209 Wisconsin St., Suite 100 ,_,omt, ress,on
Dallas, Texas 75229 z~' l'~ ~'~er~Or{.
(972) 620-8911
Tested For: CONSTRUCTION MANAGEMENT GROUP Our Report No.: 01612-28
ATTN: MR. JEFF MILLER Issue Date: 10/25/2001
5207 MCKINNEY AVENUE, SUITE 12
DALLAS, TX 75205
Fax Number: (214) 521-1279
Project Desc: COPPELL TOWN CENTER
120 N. DENTON TAPP-- COPPELL, TX
FIELD DA TA
Placement Location: PAVING, 50'S & 60'E FROM THE SE CORNER OF THE BUILDING
Date Placed: 10/12/01 Plant Number: -4000
Time Placed: 8:30 AM Delivery Ticket No.: 102396
Slump (ASTM C-143): 3.0 Made By:. ALPHA
Air Content: 4.2 (ASTM C-173) Cured Specification: ASTM C-31
Air Temperature: 57
Specimen Temperature: 60
Date Received: 10/13/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted B~ AZMAR, OMAR
Mix Data Submitted By: NELSON
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: T~/pe: spec: Tested: IDa~/sl: Len~h Width Diameter Sq. In. Load: PSI:
25 LAB C-1231 10/19/01 7 12 N/A 5 28.27 109310 3860
26 LAB 11/9/01 28 12 N/A 6 28.27 0
27 LAB 11/9/01 28 12 N/A 6 28.27 0
28 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 4000
Results to Date: N/A
Notes:
CC: HIS, CITY OF COPPELL, CONSTRUCTION MANAGEMENT GROUP
Respectfully Submitted By: /IV of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client (and their designated receplents on file in our office) and shall not be reproduced and/or dlsldbuted except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed, and are not indlcalive of the qualities of apparenlly Identlcal or similar specimens.
/~LPHA TESTING, INC.
2209 Wisconsin St., Suite 100 Concrete Compression Test
Dallas, Texas 75229 Report
(972) 620-8911
Tested For: CONSTRUCTION MANAGEMENT GROUP Our Report No.: 01612-18
A'I-I'N: MR. JEFF MILLER Issue Date: 10/25/2001
5207 MCKINNEY AVENUE, SUITE 12
DALLAS, TX 75205
Fax Number: (214) 521-1279
Project Desc: COPPELL TOWN CENTER
120 N. DENTON TAPP-- COPPELL, TX
FIELD DA TA
Placement Location: PAVING, 75~N & 20'N FROM THE NE CORNER OF THE PROPOSED BUILDING
Date Placed: 9/21/01 Plant Number: 89-4000
Time Placed: 9:30 AM Delivery Ticket No.: 89002421
Slump (ASTM C-143): 5.5 Made By: ALPHA
Air Content: 5 (ASTM C-173) Cured Specification: ASTM C-31
Air Temperature: 78
Specimen Temperature: 80
Date Received: 9/22/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: BUSTAMANTE, MARTY
Mix Data Submitted By: BEALL
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: T~e: Spec: Te~ted: (De~l: Len~h Width Diametar S~. In. Load: PSI:
13 LAB C-1231 9/28/01 7 12 N/A 6 28.27 86676 3060
14 LAB C-1231 10/19/01 28 12 N/A 6 28.27 121587 4300
15 LAB C- 1231 10/19/01 28 12 N/A 6 28.27 126470 4470
16 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3600
Results to Date: PASS
Note~:
CC: HIS, CITY OF COPPELL, CONSTRUCTION MANAGEMENT GROUP
Respectfully Submitted By: ,~k,~_ ~'~1~ of Alpha Testing, Inc.
Our test results and reports are for the exclusive use-o;:]t:(/rCIlen a/ndand their designated receplents on file in our office)and shall not be reproduced and/or dbtrlbuted except
with expre~ approval of ALPHA. The use of our name and test results must receive our written approval. Te~ results and reports apply only to the samples tested and/or
observed, and are not indicative of the qualities of apparently identical or similar specimens.