ST0004-LR011120 ~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080
? ~ - Concrete Compression Test Report
Client: ~ty of Co~pell Report Distribution: (1) The City of Coppell
Project:// Freeport Parkway Pavement (1) Quantum Contracting
Repair
TMI Rep~No.:~1-066-082
Report Date: 11/20/2001
Specifications Test Data
Strength 4000 psi @ 28 Days Placement Date 10/23/2001
Slump 5 in max Sampled By Bobby Ratliff
Air Content 3 % min 6 % max Weather PT. CLOUDY
Concrete Temperature n/a Supplier/Mix Hanson/9636
Ambient Temperature n/a Air Content Method ASTM C-231-B
Ticket Number: 598 Time Batched: 5:17 PM Time Sampled: 5:50 PM
Slump: 7.25 in* Air Content: 4.0 % Unit Weight: N/A
Concrete Temperature: 80° F Ambient Temperature: 76° F Yardage (c.y.): 10 of 130
Placement Location: Paving, south bound Freeport Parkway
Sample Location: #32
An asterisk (*) appears next to field data which does NOT meet specifications.
Cylinder Age, Max Load Area Strength Fracture
Set # # Test Date (days) (lbs. force) (sq.in.) (psi} Type
I FPP10230101 10/30/2001 7 125120 28.27 4420 unbonded cap
I FPP10230102 11/20/2001 28 147760 28.27 5230 unbonded cap
I FPP10230103 11/20/2001 28 152950 28.27 5410 unbonded cap
I FPP10230104 Hold
28 day average 5320
Normal cylinder size: 6" x 12"
~SCOTT M. PETTIT
TERRA-MAR, INC.
Sr. Vice President
The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of
this report, or any part therein, is strictly prohibited without the express written consent of TMI.
OIMEM Page I o1'2