Loading...
Villages of CC P5-LR 961004 ~ ~ CO.N~ULTING ENGINEERS IN: ~1~t ..nv|ron~enta~ Assessments Z~* Soils & Foundations Construction HateriaLs Testing ,,ExceLLence byExperience" Coarnercia[ & industrial Inspection PO Box 925&8 · South[ake, Texas 76092 · (817) 329-0281 FIELD COMPACTION REPORT PROJECT: Villages of Cottonwood Creek V LOCATION: Coppell JOB #: 96-1779 DATE: 10-04-96 DAY: Friday TIME: 2:00pm CLIENT: Grand Land 96, LP CONTRACTOR: Site Concrete c/o Grand Homes, Inc WATER DRY PER- TEST PROCTOR CONT. DEN CENT NO. LOCATION AND LIFT NUMBER (%) (PCF) COMP Block A: 1. @ Lot 16 2nd Lift 4 25.2 98.7 97.0 2. @ Lot 15 1st Lift 4 24.3 99.8 98.1 3. @ Lot 14 1st Lift 4 23.9 100.6 98.9 Eastwick Ln: 4. @ Station 1+50 2nd Lift 4 26.0 97.2 95.5 REMARKB: Ail tests passed. Minimum Compaction Required: 95% PROCTORS: 1. Reddish Brn Sandy Clay 112.4 PCF @ 11.6% MOISTURE 2. Brn Clayey Sand 111.3 PCF @ 17.2% MOISTURE 3. Dk Brn Silty Sandy Clay 104.4 PCF @ 18.2% MOISTURE 4. Reddish Brn Silty Sandy Clay 101.7 PCF @ 22.8% MOISTURE Jeff Holden Technician