Loading...
CF-Coppell Rd SC-LR010918Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF IN-PLACE DENSITY TESTS CLIENT: Texas Unified Constructors, Inc. PROJECT:~s & Maintenance Fac. DATE: JOB NO.: MATERIAL DESCRIPTION: 1) Borrow Fill - Dark Grey & Brown Clay with Gravel 18 September 2001 01.1054 ASTM D 698 STANDARD PROCTOR: 1) 99.0 pcf @ 20.5% Moisture 34) 35) 36) 37) LOCATION PROCTOR LIFT Fire Lane/Drive South of Buildin.q approx. 20' south of south bldg. line approx. 30' west of east bldg. line East Parking Area approx. 100' north of south bldg. line approx. 30' west of east bldg. line approx. 175' north of south bldg. line approx. 50' west of east bldg. line approx. 225' north of south bldg. line approx. 60' west of east bldg. line MOISTURE DRY PERCENT CONTENT DENSITY COMPACTION % PCF % 1 3 21.0 99.0 100.0 1 1 21.4 95.1 96.1 1 1 21.7 96.1 97.1 1 1 20.6 97.2 98.2 REQUIRED COMPACTION % 95+ -1% to +3% Of Optimum TECHNICIAN: DISTRIBUTION: CDJ (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148