Loading...
Coppell Industrial-LR010614 GEOTECHNICAL AND I G F=J r--i U F=~ ENVIRONMENTAL CONSULTANTS'l CONCRETE CYLINDER TEST REPORT TradePoint One Bethel Road and Royal Lane Coppell, Texas REPORTED TO: CP-Coppell Industrial, Ltd. REPORT NO. 107 c/o Champion Partners, Ltd. REG PROJECT NO. 7394 15601 Dallas Parkway, Suite 100 SAMPLE DATE: 06-14-01 Addison, Texas 75001 TECHNICIAN: W. Eberhardt ATTN: Mr. Kerry Burden CONTRACTOR: C.D. Henderson, Inc. Location of Sample Set Number J Location J Quantity Represented J 1 Piers: H-13, F-24 and F-23 10/50 I Design Information Source of Concrete J Mix Identification J Specified Strength p.s.i. J Potter 9337 3000 I Test Results Set ICylinder Age@ TotalLoad I CompressiveI Average No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i. 1 9180 06-21-01 7 108410 3840 9180 07-12-01 28 9180 07-12-01 28 Cylinder Data SetI Cylinder I Time of Concrete Air Ticket No. ID Slump Sample Air Temp. Temp. Entrainment Number 1 9180 6.00 11:15AM 91 84 N/A 611843 Mail Submitted by: Distribution: (1) Champion Partners, Ltd./ Mr. Kerry Burden REED ENGINEERING GROUP, INC. (1) C.D.Henderson, Inc./ Mr. Jason Nunley Original Signed By (1) AECC, Inc./Mr. Fran Carter (1) Meinhardt & Quintana/ Keith Atkins Mr. David Meinhardt KENje (1) Haynes Whayley Associates, Inc./ Mr. Kent Penrod (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) Potter Concrete/Mr. Brent Cox 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 * -SL [214] 350 5600 * FaX [214] 350 0019