Coppell Industrial-LR010614 GEOTECHNICAL AND I G F=J r--i U F=~
ENVIRONMENTAL CONSULTANTS'l
CONCRETE CYLINDER TEST REPORT
TradePoint One
Bethel Road and Royal Lane
Coppell, Texas
REPORTED TO: CP-Coppell Industrial, Ltd. REPORT NO. 107
c/o Champion Partners, Ltd. REG PROJECT NO. 7394
15601 Dallas Parkway, Suite 100 SAMPLE DATE: 06-14-01
Addison, Texas 75001 TECHNICIAN: W. Eberhardt
ATTN: Mr. Kerry Burden
CONTRACTOR: C.D. Henderson, Inc.
Location of Sample
Set Number J Location J Quantity Represented J
1 Piers: H-13, F-24 and F-23 10/50
I
Design Information
Source of Concrete J Mix Identification J Specified Strength p.s.i. J
Potter 9337 3000
I
Test Results
Set ICylinder Age@ TotalLoad I CompressiveI Average
No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
1 9180 06-21-01 7 108410 3840
9180 07-12-01 28
9180 07-12-01 28
Cylinder Data
SetI Cylinder I Time of Concrete Air Ticket
No. ID Slump Sample Air Temp. Temp. Entrainment Number
1 9180 6.00 11:15AM 91 84 N/A 611843
Mail Submitted by:
Distribution: (1) Champion Partners, Ltd./
Mr. Kerry Burden REED ENGINEERING GROUP, INC.
(1) C.D.Henderson, Inc./
Mr. Jason Nunley Original Signed By
(1) AECC, Inc./Mr. Fran Carter
(1) Meinhardt & Quintana/ Keith Atkins
Mr. David Meinhardt KENje
(1) Haynes Whayley Associates, Inc./
Mr. Kent Penrod
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
(1) Potter Concrete/Mr. Brent Cox
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 * -SL [214] 350 5600 * FaX [214] 350 0019