Loading...
Coppell Industrial-LR010613 F:=I I~_: !~: t-I' I=' I'--I I:~ I I'--I EE: ~=' I=1 i I--I [~ GEOTECHNICAL AND J J:~ I==J r-1 U J=~ ENVIP, ONIflENTAL CONSULTANTS i CONCRETE CYLINDER TEST REPORT TradePoint One Bethel Road and Royal Lane Coppell, Texas REPORTED TO: CP-Coppell Industrial, Ltd. REPORT NO. 105 c/o Champion Partners, Ltd. REG PROJECT NO. 7394 15601 Dallas Parkway, Suite 100 SAMPLE DATE: 06-13-01 Addison, Texas 75001 TECHNICIAN: W. Eberhardt ATTN: Mr. Kerry Burden CONTRACTOR: C.D. Henderson, Inc. Location of Sample Set Number I Location I Quantity Represented 1 Piers: H-17, H-16 and H-15 60/70 Design Information Source of Concrete I Mix Identification I Specified Strength p.s.i. Potter 9337 3000 Test Results Set Cylinder Age@ Total Load I CompressiveI Average No. ID Date Tested Test lbs. I IStrength p.s.i. Strength p.s.i. 1 9102 06-20-01 7 90350 3200 9102 07-11-01 28 129970 4600 9102 07-11-01 28 134000 4740 4670 Cylinder Data set I Cylinder I Time of I Concrete Air Ticket No. ID Slump Sample Air Temp. Temp. Entrainment Number 1 9102 5.00 2:30PM 97 89 N/A N/A Mail Submitted by: Distribution: (1) Champion Partners, Ltd./ Mr. Kerry Burden REED ENGINEERING GROUP, INC. (1) C.D.Henderson, Inc./ Mr. Jason Nuniey Original Signed By (1) AECC, Inc./Mr. Fran Carter (1) Meinhardt & Quintana/ Keith Atkins Mr. David Meinhardt KEAJje (1) Haynes Whayley Associates, Inc./ Mr. Kent Penrod (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) Potter Concrete/Mr. Brent Cox ~.424 STUTZ DP,. · SUITE 4.00 · DALLAS. TX 75~.35 · TEL ['214] 350 5600 · FAX [7.14] 350 0019 GEOTECHNICALAND '1 ~ F::q I~ I I p ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT TradePoint One Bethel Road and Royal Lane Coppell, Texas REPORTED TO: CP-Coppell Industrial, Ltd. REPORT NO. 105 c/o Champion Partners, Ltd. REG PROJECT NO. 7394 15601 Dallas Parkway, Suite 100 SAMPLE DATE: 06-13-01 Addison, Texas 75001 TECHNICIAN: W. Eberhardt ATTN: Mr. Kerry Burden CONTRACTOR: C.D. Henderson, Inc. Location of Sample Set Number I Location I Quantity Represented 1 Piers: H-17, H-16 and H-15 60/70 Design Information Source of Concrete I Mix Identification I Specified Strength p.s.i. I Potter 9337 3000 I Test Results Set Cylinder Age@ Total Load I CompressiveI Average No. ID Date Tested Test lbs. I IStrength p.s.i. Strength p.s.i. 1 9102 06-20-01 7 90350 3200 9102 07-11-01 28 9102 07-11-01 28 Cylinder Data SetI Cylinder I Time of I Concrete Air Ticket No. ID Slump Sample Air Temp. Temp. Entrainment Number 1 9102 5.00 2:30PM 97 89 N/A N/A Mail Submitted by: Distribution: (1) Champion Partners, Ltd./ Mr. Kerry Burden REED ENGINEERING GROUP, INC. (1) C.D.Henderson, Inc./ Mr. Jason Nunley Original Signed By (1) AECC, Inc./Mr. Fran Carter (1) Meinhardt & Quintana/ Keith Atkins Mr. David Meinhardt KEA/je (1) Haynes Whayley Associates, Inc./ Mr. Kent Penrod (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) Potter Concrete/Mr. Brent Cox 2424 STUTZ DR. · SUITE 400 · DALLAS. TX 75235 · -EL [214] 350 5600 · ~Ax [214] 350 0019