Coppell Industrial-LR010808 GEOTECHNICAL AND ~ ~ ~ U F~
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
TradePoint One
Bethel Road and Royal Lane
Coppell, Texas
REPORTED TO: CP-Coppell Industrial, Ltd. REPORT NO. 167
c/o Champion Partners, Ltd. REG PROJECT NO. 7394
15601 Dallas Parkway, Suite 100 SAMPLE DATE: 08-08-01
Addison, Texas 75001 TECHNICIAN: H. Johnson
ATTN: Mr. Kerry Burden
CONTRACTOR: C.D. Henderson, Inc.
Location of Sample
Set Number I Location I Quantity Represented
I Panel # 4 20/170
2 Panel # 9 110/170
3 Flume # 1 20/170
4 Flume # 5 110/170
Design Information
Set Number I Source of Concrete I Mix Identification I Specified Strength p.s.i.
1-2 Potter 9337 3000
3-4 Potter 7752 4000
Test Results
set I CylinderI I Age@ ] Tota, Load J Compressive I Average
No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
1 1757 08-15-01 7 90820 3210
1757 09-05-01 28 115770 4100
1757 09-05-01 28 121960 4320 4210
1757 Hold H
2 1758 08-15-01 7 93800 3320
1758 09-05-01 28 121890 4310
1758 09-05-01 28 127780 4520 4420
1758 Hold H
3 1759 08-15-01 7 94900 3360
1759 09-05-01 28 129930 4600
1759 09-05-01 28 133810 4740 4670
4 1760 08-15-01 7 90680 3210
1760 09-05-01 28 120970 4280
1760 09-05-01 28 125390 4440 4360
2424 STUTZ DR. · SUITE 400 · DALLAS. TX 75235 · TE. [214] 350 5600 · F~X [214] 350 0019
Cylinder Data
Set I Cylinder TimeofI I Concrete Air I Ticket
No. ID Slump Sample Air Temp. Temp. Entrainment Number
1 1757 5.00 5:35AM 78 85 N/A N/A
2 1758 5.00 8:00AM 96 86 N/A N/A
3 1759 4.50 10:15AM 85 90 4.4 613784
4 1760 5.00 1:40PM 94 94 4.6 613794
Mail Submitted by:
Distribution: (1) Champion Partners, Ltd./
Mr. Kerry Burden REED ENGINEERING GROUP, INC.
(1) C.D.Henderson, Inc./
Mr. Jason Nunley Original Signed By
(1) AECC, Inc./Mr. Fran Carter
(1) Haynes Whayley Associates, Inc./ Keith Atkins
Mr. Kent Penrod KEA/je
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
(1) Potter Concrete/Mr. Brent Cox
Extranet
Distribution: (1) Meinhardt & Quintana/
Mr. David Meinhardt
GEOTECHNICAL AND ~ J:=JJ I--1 U
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
TradePoint One
Bethel Road and Royal Lane
Coppell, Texas
REPORTED TO: CP-Coppell Industrial, Ltd. REPORT NO. 167
c/o Champion Partners, Ltd. REG PROJECT NO. 7394
15601 Dallas Parkway, Suite 100 SAMPLE DATE: 08-08-01
Addison, Texas 75001 TECHNICIAN: H. Johnson
ATTN: Mr. Kerry Burden
CONTRACTOR: C.D. Henderson, Inc.
Location of Sample
Set Number J Location J Quantity Represented
1 Panel # 4 20/170
2 Panel # 9 110/170
3 Flume # 1 20/170
4 Flume # 5 110/170
Design Information
Set Number J Source of Concrete J Mix Identification J Specified Strength p.s.i.
1-2 Potter 9337 3000
3-4 Potter 7752 4000
Test Results
Set CylinderI Age@ Total Load I CompressiveI Average
No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
1 1757 08-15-01 7 90820 3210
1757 09-05-01 28
1757 09-05-01 28
1757 Hold H
2 1758 08-15-01 7 93800 3320
1758 09-05-01 28
1758 09-05-01 28
1758 Hold H
3 1759 08-15-01 7 94900 3360
1759 09-05-01 28
1759 09-05-01 28
4 1760 08-15-01 7 90680 3210
1760 09-05-01 28
1760 09-05-01 28
2424 STUTZ DR. · SUITE 400 · DALLAS. TX 75235 * TEL [214] 350 5600 · FAX [214] 350 0019
Cylinder Data
Set I CylinderI ITM I ConcreteI Air I Ticket
No. ID Slump Sample Air Temp. Temp. Entrainment Number
1 1757 5.00 5:35AM 78 85 N/A N/A
2 1758 5.00 8:00AM 96 86 N/A N/A
3 1759 4.50 10:15AM 85 90 4.4 613784
4 1760 5.00 1:40PM 94 94 4.6 613794
Mail Submitted by:
Distribution: (1) Champion Partners, Ltd./
Mr. Kerry Burden REED ENGINEERING GROUP, INC.
(1) C.D.Henderson, Inc./
Mr. Jason Nunley Original Signed By
(1) AECC, Inc./Mr. Fran Carter
(1) Haynes Whayley Associates, Inc./ Keith Atkins
Mr. Kent Penrod KEA/je
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
(1) Potter Concrete/Mr. Brent Cox
Extranet
Distribution: (1) Meinhardt & Quintana/
Mr. David Meinhardt