Loading...
Villages C P4-CS 910514 LINE ONE INC . Municipal and Utility Contractor's Services ATTENTION: Dear Sir, On 5/14/91 , our company was contracted to perform sewer testing on Villages of Coppell ~4 job for Murray Construction Our testing was completed on 5/14/91 and met all the air testing and deflection requirements, per the City of Coppell specifications. We appreciate the opportunity to service the City of Coppell and hope to continue to provide our services to Zlocal~con~ractors in the near .~.uture. LINE ONE, GTS/ps P. O. BOX 160425 · IRVING, TEXAS 75016 · (214) 556-0188 bOW PRESSURE AIR TEST FOR GRAVITY SANITARY SEWER TEST PROCEDURE ,;, Each section of sewer shall be tested between successive manholes. ' Air shall be introduced into the pipeline until 4.0 psi guage pressure has been reached at which time the flow of air s'hall be reduced and the internal air pressure shall be maintained between 3.5 and 4.5 psi guage for at least two (2) minutes to allow the air temperature to come to equilibrium with the temperature of the pipe walls. Pressure in the pipeline shall be constantly monitored by _a guage and hose arrangement seperate from the hose used to introduce air into the line. Pressure in the pipe line shall not be allowed to exceed 5 ps'i. After the temperature has stabilized and no air leaks at the plugs have been found, the air pressure shall be permitted to drop and when the internal air pressure has reached 3.5 psi guage, a stop watch or sweep second hand watch shall be used to determine the time lapse required for the air pressure to drop to 2.5 psi guage. If the time lapse required for the air pressure to decrease from 3.5to 2.5 psi exceeds that shown in the following table, the pipe shall be presumed-to be within accepts!be limits for leakage. ~ If the time lapse is less than that shown in the table, the Contractor shall make the necessary corrections to reduce the leakage to acceptable limits. LINE INFORMATION TEST RESULTS AIR MANDRIL ~ I Time i Test ~ Test Line Station ~ Pipe Diameter L.F. Tested IAllowable Passed Passed A 0+00 to 1+46 10 Inch 146 L.F. C.O.G. YES YES A 1+46 to 2+82 10 Inch 136 L.F. C.O.G. YES YES A 2+82 to 5+77 10 Inch 295 L.F. C.O.G. YES YES A 5+77 to 8+77 10 Inch 300 L.F. C.O.G. YES YES A 8+77 to 10+58 10 Inch 181 L.F. C.O.G. YES YES A 10+58 to 11+52 10 Inch 95 L.F. C.O.G. YES YES A 11+53 to 12+9£ 10 Inch 137 L.F. C.O.G. YES YES B 0+00 to 1+00 10 Inch 100 L.F. C.O.G. YES YES C 0+00 to 1+10 8 Inch 110 L.F. C.O.G. YES YES EX. 0" ALLEN DR. 10 Inch APP. 200 L.F. C.O.G. YES YES i Inch L.F '1 Inch L.F Inch L.F. Inch L.F Inch L.F [__ .... Inch L.F OWNER GRAND HOMES INC. DATE 5-14-91 P[~OJEC-[ ~'L'd-[L VILLAGES OF COPPELL #4 JOB NO. 91-2 _~E~E~ LTNE ~u~AfiON FRONT EASEMENT iNS~?~TOk LARRY DAVIS CITY OF- COPPELL