Loading...
Verizon-LR 990105IN-PLACE DENSITY TESTING .... ENGINF_.ERll~, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 12/18/1998 Report No.: 9834075 Report Date 01/05/1999 Client No.: 08644025 Project No.: 43-2333-98 Client: The Beck Group Project: GTE Shared Services Attn: Gillett Berger Coppell Road & Corporate Drive 1700 Pacific Ave., Suite 3800 Dallas TX 75201-4619 Coppell, Texas Services: In-place density testing. PROJECT DATA CONTRACTOR: BECK Laboratory Test Method: ASTM D-698 Field Test Method: ASTM D-2922 ASTM D-3017 MOISTURE DENSITY RELATIONS: Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Dk reddish brown silty clayey 10.0 124.5 -1/+3% 95% ~ sand with gravel FIELD DENSITY TESTS TEST MID MOISTURE DRY DENSITY DENSITY NO TEST LOCATION No. (%) (pcf) (% max) N. Quadrant Parking Subgrade 1 Bay 4, center line between N islands 1 13.0 119.8 96 2 Bay 4, center line between middle islands 1 11.9 118.7 95 3 Bay 5, center line between N islands 1 12.7 120.2 97 4 Bay 5, center line between middle islands 1 12.7 123.1 99 Test results on this report meet project specification. Technician: Mike Odom ll-J~f~ring, Inc. Report Distribution: (I) The Beck Group (1) The Beck Group (1) Gromatzky Dupree & Assoc. gene Harbour (l) Brockette Davis Drake, Inc. Vice President (1) The Beck Group This report is exclusively for the usc of thc client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 07TMP Page 1 of 1