Verizon-LR 990105IN-PLACE DENSITY TESTING ....
ENGINF_.ERll~, INC.
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
Date of Service: 12/18/1998 Report No.: 9834075 Report Date
01/05/1999
Client No.: 08644025 Project No.: 43-2333-98
Client: The Beck Group Project: GTE Shared Services
Attn: Gillett Berger Coppell Road & Corporate Drive
1700 Pacific Ave., Suite 3800
Dallas TX 75201-4619 Coppell, Texas
Services: In-place density testing.
PROJECT DATA
CONTRACTOR: BECK Laboratory Test Method: ASTM D-698
Field Test Method: ASTM D-2922
ASTM D-3017
MOISTURE DENSITY RELATIONS:
Maximum Project Requirements
M/D No. Description Moisture % Density pcf Moisture Density
1 Dk reddish brown silty clayey 10.0 124.5 -1/+3% 95%
~ sand with gravel
FIELD DENSITY TESTS
TEST MID MOISTURE DRY DENSITY DENSITY
NO TEST LOCATION No. (%) (pcf) (% max)
N. Quadrant Parking Subgrade
1 Bay 4, center line between N islands 1 13.0 119.8 96
2 Bay 4, center line between middle islands 1 11.9 118.7 95
3 Bay 5, center line between N islands 1 12.7 120.2 97
4 Bay 5, center line between middle islands 1 12.7 123.1 99
Test results on this report meet project specification.
Technician: Mike Odom ll-J~f~ring, Inc.
Report Distribution:
(I) The Beck Group (1) The Beck Group
(1) Gromatzky Dupree & Assoc. gene Harbour
(l) Brockette Davis Drake, Inc. Vice President
(1) The Beck Group
This report is exclusively for the usc of thc client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc.
07TMP Page 1 of 1