Loading...
Freeport NIP(7.3)-LR010508REPORT OF FLOOR FLATNESS INSPECTION ENGINEERING, INC 8901 Carpenter Freeway, State 100 Dallas, Texas 75247 DATE OF SERVICE: 05/08/01 REPORT NO.: 94011157.0007 CLIENT NO.: 2691 PROJECT NO.: 94011157 CUENT: Reed Enginering Group PROJECT: Freeport 7 2424 Stutz Dr. Suite 400 Royal Lane & Creekside Dallas, Texas 75235 Coppell, Texas A FLOOR SURFACE ANALYSIS LOCATION SURVEYED: Slab-on-Grade, Pour #10 APPROXIMATE AREA: 20,000 square feet ASTM STANDARD: ASTM E 1155 INSTRUMENT USED: "Dipstick 2000", manufactured by Face Technologies SAMPLING METHOD: Point elevations were measured at regular 12 inch intervals along straight lines up to 65 feet in length. The elevation differences between all adjacent reading points, the arithmetic differences between all adjacent 12 inch elevation differences, and the elevation differences between all points separated 10 feet were then calculated. Estimates of the floor's flatness and levelness F-Numbers (FF and FL) were obtained through a statistical analysis of these calculated profile values. See attached reports for individual measurement line results. COMBINED OVERALL VALUE RESULTS: Combined Flatness F-Number (FF) 61.41 (65.75 - 57.07) Combined Levelness F-Number (Ft.) 49.25 (53.02 - 45.48) *Based upon the number of satnples taken, there is a 90% certainty that the actual F-Numbers of the surface surveyed will fall within thc ranges which fo[tow the respective estimated Flatness and Levelness F-Numbers. SPECIFIED LIMITS: Fv - Specified Overall Value: 35 FF - Minimum Local Value: N/A Ft. - Specified Overall Value: 24 FL - Minimum Local Value: N/A COMMENTS: Technician: B. Ethem. P.G. Report Distribution: Engineering, Inc. (1) Reed Engineering Group Project Manager SS This report is exclusively for the use of the client indicated above and shatl not be reproduced in full without written approval of HBC Engineering, Inc. REPORT OF FLOOR FLATNESS INSPECTION ~ ENGINEERING, INC. 8901 Carpenter Free,ray, Suite 100 Dallas, Texas 75247 PROJECT NAME: FREEPORT 7 PROJECT NO.: 94011157 DATE PLACED: 05/04/2001 REPORT NO.: 94011157.0007 DATE TESTED: 05/08/2001 SLAB-ON-GRADE, POUR #10 8 6 J RUN 03 RUN 04 RUN 02 120.0' RUN 01 L 86.0' SLAB-ON-GRADE, POUR #10 ~ NORTH NOT TO SCALE Combined Test Section DATA,FREEPORT POUR10 05042001 Run Name No. Rdgs measured Ff measured F1 RUN01 65 50.30 <42.53-58.06> 59.48 <49.45-69.51> RUN02 65 76.34 <64.55-88.13> 52.85 <43.94-61.76> RUN03 65 85.69 <72.46-98.92> 61.83 <51.41-72.26> RUN04 65 52.89 <44.72-61.06> 36.59 <30.42-42.76> Totals: 260 61.41 <65.75-57.07> 49.25 <53.02-45.48> Spec Ff: 35 Floor area above Ff Spec: 3380 sq feet. Spec Fl: 24 Floor area above F1 Spec: 4253 sq feet. HBC ENGINEERING, INC. 8901 CARPENTER FRWY. SUITE 100 DALLAS, TEXAS 75247 Phone : 214-630-1010 Fax : 214-630-7070 DIPSTICK SURVEY REPORT DATA\FREEPORT POUR10 05042001 RUN01 Report Date: 05/08/2001 Operator ID : Bulent Ethem,PG Test Date: 05/08/101 Run Length : 65 feet Data Collection Bias: N/A Min Local Ff : 20.0 Design Slope : N/A Min Local F1 : 17.0 Start Point Elev : 0.000000 F-NUMBER ANALYSIS Specified Ff : 35.0 Measured Ff : 50.30 <42.53-58.06> Specified F1 : 24.00 Measured F1 : 59.48 <49.45-69.51> ELEVATION TOLERANCE ANALYSIS No Elevation Tolerance Specified HBC ENGINEERING, INC. 8901 CARPENTER FRWY. SUITE 100 DALLAS, TEXAS 75247 Phone : 214-630-1010 Fax : 214-630-7070 DIPSTICK SURVEY REPORT DATA\FREEPORT POUR10 05042001 RUN02 Report Date: 05/08/2001 Operator ID : Bulent Ethem,PG Test Date: 05/08/101 Run Length : 65 feet Data Collection Bias: N/A Min Local Ff : 20.0 Design Slope : N/A Min Local F1 : 17.0 Start Point Elev : 0.000000 F-NUMBER ANALYSIS Specified Ff : 35.0 Measured Ff : 76.34 <64.55-88.13> Specified F1 : 24.00 Measured F1 : 52.85 <43.94-61.76> ELEVATION TOLERANCE ANALYSIS No Elevation Tolerance Specified HBC ENGINEERING, INC. 8901 CARPENTER FRWY. SUITE 100 DALLAS, TEXAS 75247 Phone : 214-630-1010 Fax : 214-630-7070 DIPSTICK SURVEY REPORT DATA, FREEPORT POUR10 05042001 RUN03 Report Date: 05/08/2001 Operator ID : Bulent Ethem,PG Test Date: 05/08/101 Run Length : 65 feet Data Collection Bias: N/A Min Local Ff : 20.0 Design Slope : N/A Min Local F1 : 17.0 Start Point Elev : 0.000000 F-NUMBER ANALYSIS Specified Ff : 35.0 Measured Ff : 85.69 <72.46-98.92> Specified F1 : 24.00 Measured F1 : 61.83 <51.41-72.26> ELEVATION TOLERANCE ANALYSIS No Elevation Tolerance Specified HBC ENGINEERING, INC. 8901 CARPENTER FRWY. SUITE 100 DALLAS, TEXAS 75247 Phone : 214-630-1010 Fax : 214-630-7070 DIPSTICK SURVEY REPORT DATA\FREEPORT POUR10 05042001 RUN04 Report Date: 05/08/2001 Operator ID : Bulent Ethem,PG Test Date: 05/08/101 Run Length : 65 feet Data Collection Bias: N/A Min Local Ff : 20.0 Design Slope : N/A Min Local F1 : 17.0 Start Point Elev : 0.000000 F-NUMBER ANALYSIS Specified Ff : 35.0 Measured Ff : 52.89 <44.72-61.06> Specified F1 : 24.00 Measured F1 : 36.59 <30.42-42.76> ELEVATION TOLERANCE ANALYSIS No Elevation Tolerance Specified HBC ENGINEERING, INC. 8901 CARPENTER FRWY. SUITE 100 DALLAS, TEXAS 75247 Phone : 214-630-1010 Fax : 214-630-7070