Loading...
Freeport NIP(7.3)-LR010501 GEOTECHNICAL AND ENVIRONMENTAL CONSULTANTS I CONCRETE CYLINDER TEST REPORT Freeport VII Royal Lane, North of Bethel Road Coppell, Texas REPORTED TO: Duke-Weeks Realty Corporation REPORT NO. 79 5495 Belt Line Road, Suite 360 REG PROJECT NO. 7570 Dallas, Texas 75240 SAMPLE DATE: 05-01-01 ATTN: Mr. Jeff Langston TECHNICIAN: S. Davis/D. Rico CONTRACTOR: Raymond Construction Location of Sample Set Number I Location I Quantity Represented 1 Panel # 52 240/580 2 Panel #59 330/580 3 Panel # 63 420/580 4 Panel # 71 530/580 Design Information Source of Concrete I Mix Identification I Specified Strength p.s.i. I Potter 9349 4000 I Test Results Set Cylinder I Age @ Total Load Compressive Average No. ID I Date Tested Test lbs. Strength p.s.i. Strength p.s.i. 1 6854 05-08-01 7 109570 3880 6854 05-29-01 28 141570 5010 6854 05-29-01 28 150430 5320 5170 6854 Hold H 2 6992 05-08-01 7 125100 4430 6992 05-29-01 28 151340 5360 6992 05-29-01 28 154340 5460 5410 6992 Hold H 3 6993 05-08-01 7 103440 3660 6993 05-29-01 28 145860 5160 6993 05-29-01 28 148220 5250 5210 6993 Hold H 4 6994 05-08-01 7 138480 4900 6994 05-29-01 28 163310 5780 6994 05-29-01 28 160950 5700 5740 6994 Hold H 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019 Cylinder Data Set Cylinder Time of I Concrete Air Ticket No. ID Slump Sample AirTemp.I Temp. Entrainment Number 1 6854 5.00 7:00AM 72 78 N/A 610742 2 6992 4.75 8:15AM 72 73 N/A 610751 3 6993 5.00 9:45AM 75 75 N/A 610760 4 6994 5.00 11:23AM 80 75 N/A 610770 Mail Submitted by: Distribution: (1) Duke-Weeks Realty Corporation/ Mr. Jeff Langston REED ENGINEERING GROUP, INC. (1) Raymond Construction/ Mr. Dave Schlimme Original Signed By (1) City of Coppell/Mr. Larry Davis Keith Atkins KEA/je GEOTECHNICAL AND ~ Rrl I I p ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Freeport VII Royal Lane, North of Bethel Road Coppell, Texas REPORTED TO: Duke-Weeks Realty Corporation REPORT NO. 78 5495 Belt Line Road, Suite 360 REG PROJECT NO. 7570 Dallas, Texas 75240 SAMPLE DATE: 05-01-01 ATTN: Mr. Jeff Langston TECHNICIAN: S. Davis CONTRACTOR: Raymond Construction ~ Location of Sample Set Number I Location I Quantity Represented 1 Piers: L.9-21.1, M-20.3, L.9-20.3 and M-19.7 10/10 Design Information Source of Concrete I Mix Identification I Specified Strength p.s.i. Potter 9337 3000 Test Results Set Cylinder J Age@ Total Load I Compressive[ Average No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i. 1 6853 05-08-01 7 85300 3020 6853 05-29-01 28 100400 3550 6853 05-29-01 28 117650 4160 3860 6853 Hold H Cylinder Data Set CylinderI I Timeof J ConcreteI Air J Ticket N1. ID Slump Sample Air Temp. Temp. Entrainment Number 6853 3.00 2:30PM 83 90 N/A 610778 Mail Submitted by: Distribution: (1) Duke-Weeks Realty Corporation/ Mr. Jeff Langston REED ENGINEERING GROUP, INC. (1) Raymond Construction/ Mr. Dave Schlimme Original Signed By (1) City of Coppell/Mr. Larry Davis Keith Atkins KEA/je 2424 STUTZ DR. · SUITE 400 * DALLAS, TX 75235 · TEL [214] 350 5600 * FAX [214] 350 0019