Loading...
Freeport NIP(7.3)-LR010417 GEOTECHNICALAND I ~ ~ I~1 I I ~ ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Freeport VII Royal Lane, North of Bethel Road Coppell, Texas REPORTED TO: Duke-Weeks Realty Corporation 5495 Belt Line Road, Suite 360 Dallas, Texas 75240 ATTN: Mr. Jeff Langston CONTRACTOR: Raymond Construction Location of Sample Set Number I Location I Piers: G-4, H-4, J-4, K-4 REPORT NO. 56 REG PROJECT NO. 7570 SAMPLE DATE: 04-17-01 TECHNICIAN: S. Davis Quantity Represented 10 Design Information Source of Concrete I Mix Identification Potter 9337 Specified Strength p.s.i. 3OOO Test Results Set CylinderI I Age@ No. ID Date Tested Test 6075 04-24-01 7 6075 05-15-01 28 6075 05-15-01 28 3075 Hold H I Total Load I CompressiveI Average lbs. Strength p.s.i. Strength p.s.i. 116520 4120 138510 4900 140300 4970 4940 Cylinder Data Set Cylinder ID 6075 Time of Slump Sample 3.50 11:30 AM 49 I Concrete Air Ticket Air Temp. Temp. Entrainment Number 64 N/A 5893 Mail Distribution: (1) Duke-Weeks Realty Corporation/ Mr. Jeff Langston (1) Raymond Construction/ Mr. Dave Schlimme (1) City of Coppell/Mr. Larry Davis Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/mm 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019