Loading...
CF-Coppell Rd SC-LR011120 Hooper Engineering Laboratories, Inc. Construction Materials Testing REINFORCING STEEL PLACEMENT INSPECTION CLIENT: Texas Unified Constructors, Inc. DATE: 20 November 2001 PROJECT: Field Service Offices & Maintenance Facility JOB NO. 01.1054 Coppell, TX TIME: 1.5 hours AREA INSPECTED: Service Center Building grade beams: A3.5 line to A6.5 line, A to F.5 on 5 and 6.5 line DATE OF INSPECTION: 11/20/01 (1:00pm-2:30pm) DEFICIENCIES NOTED: CORRECTIONS NUMBER LOCATION/ITEM DESCRIPTION OBSERVED 1 Clean off tops of piers. Yes 2 Slab dowels to be placed after concrete placement. Yes TECHNICIAN: RJW DISTRIBUTION: (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF IN-PLACE DENSITY TESTS CLIENT: Texas Unified Constructors, Inc. DATE: 20 November 2001 PROJECT: Field Service Offices & Maintenance Fac. JOB NO.: 01.1054 Coppell, TX MATERIAL DESCRIPTION: 1) On-Site Fill - Dark Grey Clay ASTM D 698 STANDARD PROCTOR: 1) 95.0 pcf @ 22.0% Moisture MOISTURE DRY PERCENT REQUIRED LOCATION PROCTOR LIFT CONTENT DENSITY COMPACTION COMPACTION % PCF % % BELOW Backfill Over South Water Line SUBGRADE 99) @ midpoint 1 1 '-2' 22.0 96.5 101.6 95 + Optimum +/- 2% Backfill Over Sanitary Sewer Line 100) approx. Station 1 +50 1 1' 22.7 95.2 100.2 101) 4" lateral, 100' west of main line 1 3' 23.8 90.5 95.3 NOTE: All tests passed the project requirements for density and moisture. TECHNICIAN: CDJ ~,~ ~ DISTRIBUTION: (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148