Loading...
CF-Coppell Rd SC-LR011114 (2) Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: 01.1054 CLIENT: Texas Unified Constructors, Inc. DATE: 14 November 2001 PROJECT: Field Service Offices & Maint. Fac., Coppell SUPPLIER: Lattimore LOCATION OF POUR SET 1: Grade beams at servce center building, on line 2 from A to D LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. 54 Truck Ne. 1 040 Cement Ticket No. 711 0780 Flyash Time Batched 1:49pm Sand Time Sampled 2:50pm in. Concrete Temp. (ASTM C1064) 73°F 1.0 in. Air Content (ASTM C231) Water Unit Weight (ASTM C138) Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS IASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day (ASTM C143) psi Strength 53 4.00 7 11/21/01 102,200 3620 54 4.00 28 12/12/01 55 4.00 28 12/12/01 56 4.00 56 01/09/02 28-Day Average 3000 TECHNICIAN: JWD (2:00pm-4:00pm) ~ ~ DISTRIBUTION: (3) City of Coppell (1) Vidaud & Associates (1) Doyle Engineering Group (1) Texas Unified Constructors, Inc. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148