Loading...
ST9601-LR 990605 (3)TEAM Consultants, Inc. Geotechnical, Environmental, Construction Materials Testing CONCRETE STRENGTH REPORT (ASTM C-3g), (ASTH C-78) OR (TEX-418-A), CTEX-448-A) Mr. Robert Caudill Tiseo Paving P O box 270040 Dallas, TX 75227 DATE: 06/05/1999 REPORT NO.: 70 JOB NO.: 985142 PROJECT: Wrangler Drive Coppell, Texas Cyl or Beam Date No. Location Break 44- A Inlet on comer of 05/13 B Wrangler and Crestside 05/13 C 06/03 D 06/03 45- A Comer Beltline and 05/14 B Wrangler 05/14 C 06/04 D 06/04 Slump(in.) Air (%) Strength Date ASTM AST1VI Made (C-143) (C-23D 7-Day 28-Day 05/06 3.00 4.0 (Damaged) 05/06 (3960) 05/06 5060 05/06 5130 05/07 3.25 6.5 (3960) 05/07 (3960) 05/07 4810 05/07 4850 (nsB 28-Day Spees. 4000 4000 REMARKS: Conical fracture on cylinders unless otherwise noted. Cylinder diameter 6.00" unless otherwise noted. ke cc: City of Coppell TEAM Consultants, Inc. Ronald L. Bannister 2970 S. Walton Walker, Suite 101 Dallas, TX 75211 (214) 331-4395 Fax (214) 331-4458 310! Pleasant Valley, Suite 101 Arlington, TX 76015 (817) 467-5500 Fax (817) 468-9920 T.F¸