ST9601-LR 990605 (3)TEAM Consultants, Inc.
Geotechnical, Environmental, Construction Materials Testing
CONCRETE STRENGTH REPORT
(ASTM C-3g), (ASTH C-78) OR (TEX-418-A), CTEX-448-A)
Mr. Robert Caudill
Tiseo Paving
P O box 270040
Dallas, TX 75227
DATE: 06/05/1999 REPORT NO.: 70
JOB NO.: 985142
PROJECT: Wrangler Drive
Coppell, Texas
Cyl or
Beam Date
No. Location Break
44- A Inlet on comer of 05/13
B Wrangler and Crestside 05/13
C 06/03
D 06/03
45- A Comer Beltline and 05/14
B Wrangler 05/14
C 06/04
D 06/04
Slump(in.) Air (%) Strength
Date ASTM AST1VI
Made (C-143) (C-23D 7-Day 28-Day
05/06 3.00 4.0 (Damaged)
05/06 (3960)
05/06 5060
05/06 5130
05/07 3.25 6.5 (3960)
05/07 (3960)
05/07 4810
05/07 4850
(nsB
28-Day
Spees.
4000
4000
REMARKS: Conical fracture on cylinders unless otherwise noted.
Cylinder diameter 6.00" unless otherwise noted.
ke
cc: City of Coppell
TEAM Consultants, Inc.
Ronald L. Bannister
2970 S. Walton Walker, Suite 101 Dallas, TX 75211 (214) 331-4395 Fax (214) 331-4458
310! Pleasant Valley, Suite 101 Arlington, TX 76015 (817) 467-5500 Fax (817) 468-9920
T.F¸