Freeport NIP(2.2)-LR011123- REPORT OF DRILLED BELLED PIER OBSERVATION Report Number: 94011204.0065 Service Date: November 14, 2001 89Ol Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: November 23, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Services: Drilled belled pier observation. On this date, an HBC Engineering technician arrived at the above referenced jobsite as scheduled for drilled belled pier observation. See the attached sheet for recorded data. Report Distribution: Inc. (1) TNA North American, Inc. (1) FACServices Inc (1) Carrell Poole & Yost Architecture (1) David Kent Reviewed by: , (1) R L Goodson Consulting Engineers (1) City of Coppell - Bldg Insp Eric J. Ci~veland, P.E. (1) Pacific Builders Inc (1) City of Coppell - Constr Insp Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 9,-SO~'~-F~..Key REPORT OF DRILLED BELLED PIERS ENGINEERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Prolect: Sales Office & Warehouse Fac. Report No.: 94011204.0065 Coppell, Texas Date ot Service: 11/14/01 ProlectNo.: 94011204 Technioian: S. Campbell Driller: Auger Drilling Inc. Page: ! of ! Pier Identification B.4/7.2 B.7/7.2 B.9/7.2 C.3/7.2 C.7/7.2 Pier Diameter (in.) 18 18 18 18 18 Bell Diameter (in.) 36 36 36 36 36 *Top of Pier Elevation (ft) N/A N/A N/A N/A N/A Req. Depth from Exist. Grade (ft~ 15.0 15.0 15.0 15.0 15.0 Initial Depth of Pier from Existing Grade (fi) 14.8 15.0 14.9 14.3 15.5 Final Depth of Pier from Existing Grade (fi) 14.8 15,1 15.0 14.5 15.5 Depth from Top of Concrete (ft) 13.5 13.8 13.7 13.2 14.2 Condition of Bottom (wet or dry) Dry Dry Dry Dry Dry Plumb Within Tolerance (yes or no) Yes Yes Yes Yes Yes Casing Diameter (in) N/A N/A N/A N/A N/A Cased Depth (ft) N/A N/A N/A N/A N/A Number of Vertical Bars (ea.) 5 5 5 5 5 Reinforcing Bar Size (#) 6 6 6 6 6 Length of Vertical Bars (ft.) 15.4 16.0 15.8 15.2 16.1 Time Drilling was Completed 10:00 a.m. 10:30 a.m. 11:00 a.m. 11:30 a.m. 12:15 p.m. Time Concrete was Placed 10:10a.m. 10:40a.m. 11:20a.m. 11:45a.m. 2:00p.m. *Elevation was provided by others. REPORT OF STRUCTURAL STEEL OBSERVATION Report Number: 94011204.0061 Service Date: November 12, 2001 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: November 23, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Services: Structural steel observation. On this date, an HBC Engineering technician arrived at the above referenced jobsite as scheduled for structural steel observation. A visual observation was conducted on the Roof Level Framing between lines 1 to 7 and A to D as noted below. 1. Metal deck installation, puddle welds and side lap screws were found to be noncompliant. Technician: Melvin Luttrell Report Distribution: ~~/~g, Inc. (1) TNA North American, Inc. (1) FACServices Inc (1) Carrell Pocle & Yost Architecture (1) David Kent Reviewed by: (1) R L Goodson Consulting Engineers (1) City of Coppell- Bldg Insp Eric J. Cleveland, P.E. (1) Pacific Builders Inc (1) City of Coppell - Constr Insp Senior Project Engineer The tests were performed in general accordance w th applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1