Loading...
Freeport NIP(2.2)-LR011120 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94011204.0047 8901 Carpenter Frwy., Suite #100 Service Date: October 22, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: November 20, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 5:38am Date Cast: October 22, 2001 Technician: Marlo Garcia Batch Time: 4:46am Plant: 41 Weather Conditions: Cool, w/slight breeze Supplier: TXI Accumulative Yards: 90 Truck No: 483 Ticket No: 3005280 Placement Method: Pump Mix I.D. No.: 9001P Sample Locations: Taken @ panel #7 Placement Location: Panels: From panel #1-14 & from 16-31 Field Test Data Test Result Specification Test Method Slump, inches: 6.00 3-5 ASTM C-143 Air Content, %: 3.7 3-6 ASTM C-231 Concrete Temperature, o F: 75 ASTM C1064 Ambient Temperature, o F: 71 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 10/26/2001 4 65,630 2,320 1 2 6.00 28.27 10/29/2001 7 80,290 2,840 1 3 6.00 28.27 10/29/2001 7 76,950 2,720 Average 2,780 1 4 6.00 28.27 11/19/2001 28 103,730 3,670 1 5 6.00 28.27 11/19/2001 28 104,320 3,690 Average 3,680 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AAS HTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6 o~-~w~0, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94011204.0047 Service Date: October 22, 2001 89Ol Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: November 20, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 7:48am Date Cast: October 22, 2001 Technician: Marlo Garcia Batch Time: 6:01 am Plant: 41 Weather Conditions: Cool w/slight breeze Supplier: TXI Accumulative Yards: 190 Truck No: 483 Ticket No: 3005317 Placement Method: Pump Mix I.D. No.: 9001P Sample Locations: Taken from panel #5 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 6.50 3-5 ASTM C-143 Air Content, %: 4.1 3-6 ASTM C-231 Concrete Temperature, o F: 76 ASTM C1064 Ambient Temperature, 0 F: 71 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 10/26/2001 4 63,690 2,250 2 2 6.00 28.27 10/29/2001 7 73,080 2,580 2 3 6.00 28.27 10/29/2001 7 71,800 2,540 Average 2,560 2 4 6.00 28.27 11/19/2001 28 97,130 3,430 2 5 6.00 28.27 11/19/2001 28 100,640 3,560 Average 3,500 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6 0~_LW~,..u~. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94011204.0047 8901 Carpenter Frwy., Suite #100 Service Date: October 22, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: November 20, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 9:26am Date Cast: October 22, 2001 Technician: Marlo Garcia Batch Time: 8:14am Plant: 41 Weather Conditions: Cool, cool breeze cloudy Supplier: TXI Accumulative Yards: 290 Truck No: 837 Ticket No: 3005515 Placement Method: Pump Mix I.D. No.: 9001P Sample Locations: Taken from panel #2 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 6.50 3-5 ASTM C-143 Air Content, %: 4.1 3-6 ASTM C-231 Concrete Temperature, o F: 76 ASTM C1064 Ambient Temperature, o F: 75 ASTM C-1064 Plastic Unit Weight, pcf: Laboratorl/ Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 10/26/2001 4 63,170 2,230 3 2 6.00 28.27 10/29/2001 7 73,110 2,590 3 3 6.00 28.27 10/29/2001 7 79,440 2,810 Average 2,700 3 4 6.00 28.27 11/19/2001 28 106,100 3,750 3 5 6.00 28.27 11/19/2001 28 107,990 3,820 Average 3,790 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6 0~-~w~o~ T 1-Iu'"~ CONCRETE COMPRESSIVE STRENGTH TEST ~ad, v,.~,..~f~r~.:~ Report Number: 94011204.0047 ~,~=~J~.~c 8901 Carpenter Frwy., Suite #100 Service Date: October 22, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: November 20, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1521 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3000 psi (~ 28 Days Sample Time: 10:59am Date Cast: October 22, 2001 Technician: Marlo Garcia Batch Time: 10:01am Plant: 41 Weather Conditions: Cool Supplier: TXI Accumulative Yards: 390 Truck No: 111 Ticket No: 3005698 Placement Method: Pump Mix I.D. No.: 9001P Sample Locations: Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 6.50 3-5 ASTM C-143 Air Content, %: 4.5 3-6 ASTM C-231 Concrete Temperature,° F: 76 ASTM C1064 Ambient Temperature, o F: 79 ASTM C-1064 Plastic Unit Weight, pcf: Laborator~ Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 4 1 6.00 28.27 10/26/2001 4 61,930 2,190 4 2 6.00 28.27 10/29/2001 7 81,040 2,870 4 3 6.00 28.27 10/29/2001 7 83,400 2,950 Average 2,910 4 4 6.00 28.27 11/19/2001 28 108,750 3,850 4 5 6.00 28.27 11/19/2001 28 111,680 3,950 Average 3,900 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM. AASHTO, or DOT test methods, This report is exclusively for the use of ~ client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, o,-~w~,-F~. Key Page 4 of 6 CONCRETE COMPRESSIVE STRENGTH TEST .[...j..,~.,,,.~,,,.o~r,~,--,~ Report Number: 94011204.0047 ~'~'~' 89Ol Carpenter Frwy., Suite #100 Service Date: October 22, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA North American, Inc. Report Date: November 20, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3000 psi (~ 28 Days Sample Time: 1:49pm Date Cast: October 22, 2001 Technician: Marlo Garcia Batch Time: Plant: 41 Weather Conditions: Warm Supplier: TXI Accumulative Yards: 490 Truck No: 450 Ticket No: 3005931 Placement Method: Pump Mix I.D. No.: 9001P Sample Locations: Taken at Panel #22 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 7.50 3-5 ASTM C-143 Air Content, %: 4.7 3-6 ASTM C-231 Concrete Temperature, o F: 81 ASTM C1064 Ambient Temperature, 0 F: 85 ASTM C-1064 Plastic Unit Weight, pcf: Laborator~ Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 5 1 6.00 28.27 10/26/2001 4 52,410 1,850 5 2 6.00 28.27 10/29/2001 7 64,440 2,280 5 3 6.00 28.27 10/29/2001 7 65,240 2,310 Average 2,300 5 4 6.00 28.27 11/19/2001 28 93,630 3,310 5 5 6.00 28.27 11/19/2001 28 94,700 3,350 Average 3,330 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, o,~.Lw~o, Page 5 of 6 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94011204.0047 8901 Carpenter F~vy., Suite #100 Service Date: October 22, 2001 Dallas, Texas 75247 (214) 630-1010 Client: TNA Nodh American, Inc. Report Date: November 20, 2001 Attn: Terry Raley Project: Sales Office & Warehouse Fac. 1321 Valwood Parkway, Suite 440 Coppell, Texas Carrollton TX 75006 Project Number: 94011204 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 2:46pm Date Cast: October 22, 2001 Technician: Marlo Garcia Batch Time: 2:08pm Plant: 41 Weather Conditions: Warm Supplier: TXI Accumulative Yards: 530 Truck No: 67 Ticket No: 3006162 Placement Method: Pump Mix I.D. No.: 9001P Sample Locations: Taken (~ panel #17 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.50 3-5 ASTM C-143 Air Content, %: 4.6 3-6 ASTM C-231 Concrete Temperature, o F: 82 ASTM C1064 Ambient Temperature, o F: 85 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 6 1 6.00 28.27 10/26/2001 4 68,010 2,400 6 2 6.00 28.27 10/29/2001 7 82,940 2,930 6 3 6.00 28.27 10/29/2001 7 85,940 3,040 Average 2,990 6 4 6.00 28.27 11/19/2001 28 110,180 3,900 6 5 6.00 28.27 11/19/2001 28 109,290 3,860 Average 3,880 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Report Distribution: ' ' Inc. (1) TNA North American, Inc. (1) FACServices Inc (1) Carrell Poole & Yost Architecture (1) David Kent Reviewed by: (1) R L Goodson Consulting Engineers (1) City of Coppell - Bldg Insp ~ J' Cl~P~.Land, P.E. (1) Pacific Builders Inc (1) City of Coppell - Constr Insp Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, o~-~Lw~o, Fu~, K,y Page 6 of 6