Loading...
ST9601-LR 990327TEAM Consultants, Inc. Geotechnical, Environmental, Construction Materials Testing CONCRETE STRENGTH REPORT (ASTM C-39), (ASTM C-78) OR (TEX-4:!.8-A), (TEX-448-A) Mr. Robert Caudill Tiseo Paving P O Box 270040 Dallas, TX 75227 DATE: 03/27/1999 REPORT NO.: JOB NO.: 985 142 PROJECT: Wrangler Drive Coppell, Texas 56 Page 1 of 2 Cyl or Slump(in.) Air (%) Beam Date Date ASTM AST~I No. Location Break Made (C-143) (C-231) 28- A Sta 49+50, road 03/22 03/15 5.50 6.5 B 03/22 03/15 C 04/12 03/15 D 04/12 03/15 29- A Sta 37+14, road 03/22 03/15 6.00 9.0 B 03/22 03/15 C 04/12 03/15 D 04/12 03/15 30- A Sta 35+50 03/22 03/16 2.75 6.0 B 03/23 03/16 C 04/13 03/16 D 04/13 03/16 31- A Sta 33+00 03/22 03/16 3.00 7.0 B 03/23 03/16 C 04/13 03/16 D 04/13 03/16 32- A Sta 31+50 03/22 03/16 3.50 4.0 B 03/23 03/16 C 04/13 03/16 D 04/13 03/16 33- A Sta 30+00 03/22 03/16 4.00 7.0 B 03/23 03/16 C 04/13 03/16 D 04/13 03/16 34- A Sta 28+60 03/22 03/16 4.00 6.0 B 03/23 03/16 C 04/13 03/16 D 04/13 03/16 35- A Sta 26+00 03/22 03/16 3.50 6.0 B 03/23 03/16 C 04/13 03/16 D 04/13 03/16 Strength (psi) 28-Day 7-Dav 28-Dav Specs. 2120 4000 2090 1590 4000 1730 2370* 4000 2690 2120' 4000 2480 1870' 4000 4240 3860* 4000 4670 2720* 4000 3150 2510' 4000 2900 2970 S. Walton Walker, Suite 101 Dallas, TX 75211 (214) 331-4395 Fax (214) 331-4458 3101 Pleasant Valley, Suite I01 Arlington, TX 76015 (817) 467-5500 Fax (817) 468-9920 · l ' m ! ....[ .... I "l CONCRETE STRENGTH REPORT (ASTM C-3g), (ASTM C-78) OR (TEX-41.8-A), (TEX-448-A) Mr. Robert Caudill Tiseo Paving P O Box 270040 Dallas, TX 75227 DATE: 03/27/1999 REPORT NO.: JOB NO.: 985142 PROJECT: Wrangler Drive Coppell, Texas 56 Page 2 of 2 Cyl or Slump(in.) Air (%) Beam Date Date ASTM ASTM No. Location Break Made (C-143) (C-231) 36- A Sta 24+60 03/22 03/16 3.75 6.0 B 03/23 03/16 C 04/13 03/16 D 04/13 03/16 37- A Sta 22+80 03/22 03/17 4.00 6.0 B 03/24 03/17 C 04/14 03/17 D 04/14 03/17 38- A Sta21+50 03/22 03/17 4.50 6.0 B 03/17 03/17 C 04/14 03/17 D 04/14 03/17 39- A Sta 19+50 03/22 03/17 4.75 6.5 B 03/24 03/17 C 04/14 03/17 D 04/14 03/17 40- A Sta 17+60 03/22 03/17 4.00 7.0 B 03/24 03/17 C 04/14 03/17 D 04/14 03/17 Strenk, th (psi) 28-Day 7-Dav 28-Dav Specs. 2940* 4000 3470 1980'* 4000 2260 2580** 4000 2830 2300** 4000 2620 2160'* 4000 2760 * 6 day break ** 5daybreak REMARKS: Conical fracture on cylinders unless othersvise noted. Cylinder diameter 6.00" unless otherwise noted. ke cc: City of Coppell By: TEAM Consultants, Inc. Ronald L. Bannister 'T" lea ! .... !"' T .... I "1