Loading...
ST9601-LR 980808 (3)TEAM Consultants, Inc. Mr. Robert Caudill Tiseo Paving P O Box 270040 Dallas, TX 75227 Geotechnical, Environmental, Construction Materials Testing CONCRETE STRENGTH REPORT (ASTM C-39), (ASTM C-29:~) OR (TEX420~A) DATE: 08/08/98 REPORT NO.19: JOB NO.: 985142 PROJECT: Wrangler Drive Coppell, Texas 15/19 Page 1 of 2 Cyl or Beam No. 5- A B C D 6- A B C D E 7- A B C D E 8- A B C D E 9- A B C D E 10- A B C D E II-A B C D E Location Sta 6+89, inlet west end Sta 17+00, Wrangler Sta 16+00, Wrangler Sta 14+50, Wrangler Sta 12+06, Wrangler Sta 04+00, Wrangler Sta 8+50, Wrangler Slump(in.) Air (%) Date Date ASTM ASTM Rreak Made (C-143) (C-231) 07/23 07/16 2.00 5.0 07/23 07/16 08/13 07/16 08/13 07/16 07/31 07/28 4.50 4.0 08/04 07/28 08/04 07/28 08/25 07/28 08/25 07/28 07/31 07/28 6.50 3.7 08/04 07/28 08/04 07/28 08/25 07/28 08/25 07/28 07/31 07/28 4.75 3.4 08/04 07/28 08/04 07/28 08/25 07/28 08/25 07/28 07/31 07/28 4.50 4.7 08/04 07/28 08/04 07/28 08/25 07/28 08/25 07/28 07/31 07/28 4.00 3.2 08/04 07/28 08/04 07/28 08/25 07/28 08/25 07/28 08/01 07/29 4.50 2.0 08/05 07/29 08/05 07/29 08/26 07/29 08/26 07/29 .,Streagth (psi) 28-Day 7-na~v 28-Day Specs. (3470) 4000 (3560) (2790)* 3010 2970 (2600)* 3040 2940 (2620)* 3040 3080 (2670)* 3110 3250 (2650)* 3110 3180 (2720)* 3360 3290 3000 3000 3000 3000 3000 3000 2970 S. Walton Walker, Suite 101 3101 Pleasant Valley Suite I01 Dallas, TX 75211 Arlington, TX 76015 (214) 331-4395 (817) 467-5500 Fax (214) 331-4458 Fax (817) 468-9920 IF T' e: Mr. Robert Caudill Tiseo Paving P O Box 270040 Dallas, TX 75227 CONCRETE STRENGTH REPORT (ASTM C-39), (ASTM C-293) OR (TEX-420-A) DATE: 08/08/98 REPORT NO.: 19 JOB NO.: 985142 Page 2 of 2 PROJECT: Wrangle Drive Coppell, Texas Cyl or Beam No. 12- A B C D E 13- A B C D E Location Sta 7+00, Wrangler Sta 4+00, Wrangler Slump(in.) Air (%) Strength (psi) Date Date ASTM ASTM 28-Day Rreak Made (C-143) (C-231) 7-Day 28-Day Specs. 08/01 07/29 4.50 3.0 (2690) 3000 08/05 07/29 3110 08/05 07/29 3180 08/26 07/29 08/26 07/29 08/01 07/29 6.00 3.4 (2370)* 3000 08/05 07/29 2720 08/05 07/29 2760 08/26 07/29 08/26 07/29 * 3 day break REMARKS: Conical fracture on cylinders unless otherwise noted. Cylinder diameter 6.00" unless otherwise noted. ke cc: City of Coppell TEANI Consultants, Inc. Ronald L. Bannister